VAR-202203-1529

Vulnerability from variot - Updated: 2024-11-23 22:20

Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by using a password reversed from a previously eavesdropped password hash. plural Mitsubishi Electric MELSEC iQ-F A series of products contains a vulnerability related to the use of password hashes that are not strong enough.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Mitsubishi Electric Automation (China) Co., Ltd. is a wholly-owned enterprise in China invested by Mitsubishi Electric Corporation. Mainly produces mechanical appliances for power distribution (including low-voltage circuit breakers, electromagnetic switches), electrical processing products (including CNC EDM machines, wire-cut EDM machines, and laser processing machines).

Mitsubishi MELSEC Q03UDECPU PLC has a logic flaw vulnerability, an attacker can use the vulnerability to decrypt the correct key through the encrypted password, and directly replay the message containing the key

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1529",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fx5uc-32mt\\/dss-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-40mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uc-32mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uc-32mt\\/ds-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-24mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uc-32mr\\/ds-ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uc-32mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-24mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-40mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-40mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-60mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-60mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-60mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uj-24mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx5uc-32mt/d",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uc-32mr/ds-ts",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uj-40mt/es",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uj-40mr/es",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uc",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uj-24mt/ess",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uc-32mt/dss",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uj-24mr/es",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uj-40mt/ess",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx5uj-24mt/es",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "melsec q03udecpu plc",
        "scope": null,
        "trust": 0.6,
        "vendor": "mitsubishi electric automation",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Iliya Rogachev and Artur Akhatov of Positive Technologies reported these vulnerabilities to Mitsubishi Electric.,Anton Dorfman, Dmitry Sklyarov",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-25156",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2022-25156",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-41726",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.2,
            "id": "CVE-2022-25156",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "High",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.1,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25156",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-25156",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-25156",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-41726",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-2694",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi Electric MELSEC Q series QJ72LP25(-25/G/GE) all versions, Mitsubishi Electric MELSEC L series L02/06/26CPU(-P) all versions, Mitsubishi Electric MELSEC L series L26CPU-(P)BT all versions, Mitsubishi Electric MELSEC L series LJ71C24(-R2) all versions, Mitsubishi Electric MELSEC L series LJ71E71-100 all versions and Mitsubishi Electric MELSEC L series LJ72GF15-T2 all versions allows a remote unauthenticated attacker to login to the product by using a password reversed from a previously eavesdropped password hash. plural  Mitsubishi Electric MELSEC iQ-F A series of products contains a vulnerability related to the use of password hashes that are not strong enough.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. Mitsubishi Electric Automation (China) Co., Ltd. is a wholly-owned enterprise in China invested by Mitsubishi Electric Corporation. Mainly produces mechanical appliances for power distribution (including low-voltage circuit breakers, electromagnetic switches), electrical processing products (including CNC EDM machines, wire-cut EDM machines, and laser processing machines). \n\r\n\r\nMitsubishi MELSEC Q03UDECPU PLC has a logic flaw vulnerability, an attacker can use the vulnerability to decrypt the correct key through the encrypted password, and directly replay the message containing the key",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25156"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25156",
        "trust": 3.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-090-04",
        "trust": 2.4
      },
      {
        "db": "JVN",
        "id": "JVNVU96577897",
        "trust": 2.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "id": "VAR-202203-1529",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:20:33.214000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Authentication\u00a0Bypass,\u00a0Information\u00a0Disclosure\u00a0and\u00a0Information\u00a0Tampering\u00a0Vulnerabilities\u00a0in\u00a0Multiple\u00a0FA\u00a0Products",
        "trust": 0.8,
        "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-031_en.pdf"
      },
      {
        "title": "Patch for Mitsubishi MELSEC Q03UDECPU PLC has logic flaw vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/332961"
      },
      {
        "title": "Mitsubishi Electric MELSEC iQ-F series Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=194631"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-326",
        "trust": 1.0
      },
      {
        "problemtype": "Using weak password hashes (CWE-916) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-04"
      },
      {
        "trust": 1.6,
        "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-031_en.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://jvn.jp/vu/jvnvu96577897/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu96577897/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25156"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25156/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-090-04"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "date": "2022-03-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      },
      {
        "date": "2022-04-01T23:15:14.253000",
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-05-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-41726"
      },
      {
        "date": "2022-04-20T05:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      },
      {
        "date": "2022-06-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      },
      {
        "date": "2024-11-21T06:51:42.703000",
        "db": "NVD",
        "id": "CVE-2022-25156"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Mitsubishi\u00a0Electric\u00a0MELSEC\u00a0iQ-F\u00a0 Insufficient password hash usage vulnerabilities in series products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001564"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-2694"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.