VAR-202112-2105

Vulnerability from variot - Updated: 2024-08-14 14:31

A stack buffer overflow was discovered on Realtek RTL8195AM device before 2.0.10, it exists in the client code when an attacker sends a big size Authentication challenge text in WEP security. Realtek RTL8195AM The device contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Realtek RTL8195AM is an IoT microcontroller from Taiwan Realtek Semiconductor (Realtek). The Realtek RTL8195AM version before 2.0.10 has a buffer error vulnerability. The vulnerability is caused by the lack of effective processing of large-length text in the software, which leads to a stack buffer overflow. Attackers can send large-size Authentication challenge texts to achieve client-side exploits

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2105",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "rtl8195am",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "realtek",
        "version": "2.0.10"
      },
      {
        "model": "rtl8195am",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "realtek semiconductor corp",
        "version": "rtl8195am  firmware  2.0.10"
      },
      {
        "model": "rtl8195am",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "realtek semiconductor corp",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "cve": "CVE-2021-39306",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2021-39306",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2021-39306",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-39306",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-39306",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-39306",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202112-2203",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-39306",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-39306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A stack buffer overflow was discovered on Realtek RTL8195AM device before 2.0.10, it exists in the client code when an attacker sends a big size Authentication challenge text in WEP security. Realtek RTL8195AM The device contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Realtek RTL8195AM is an IoT microcontroller from Taiwan Realtek Semiconductor (Realtek). \nThe Realtek RTL8195AM version before 2.0.10 has a buffer error vulnerability. The vulnerability is caused by the lack of effective processing of large-length text in the software, which leads to a stack buffer overflow. Attackers can send large-size Authentication challenge texts to achieve client-side exploits",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-39306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-39306"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-39306",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-39306",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-39306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "id": "VAR-202112-2105",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.20833333
  },
  "last_update_date": "2024-08-14T14:31:28.327000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page Security\u00a0Bulletin",
        "trust": 0.8,
        "url": "https://www.realtek.com/en/"
      },
      {
        "title": "Realtek RTL8195AM Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177015"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://www.realtek.com"
      },
      {
        "trust": 1.7,
        "url": "https://www.amebaiot.com/en/security_bulletin/cve-2021-39306/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-39306"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-39306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2021-39306"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-12-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-39306"
      },
      {
        "date": "2022-12-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "date": "2021-12-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      },
      {
        "date": "2021-12-22T19:15:11.373000",
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-01-04T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-39306"
      },
      {
        "date": "2022-12-28T03:13:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      },
      {
        "date": "2022-01-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      },
      {
        "date": "2022-01-04T18:49:37.060000",
        "db": "NVD",
        "id": "CVE-2021-39306"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Realtek\u00a0RTL8195AM\u00a0 Out-of-bounds write vulnerabilities in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-017048"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202112-2203"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour