VAR-202110-1807
Vulnerability from variot - Updated: 2025-08-20 23:06NETGEAR Multiple Routers httpd Missing Authentication for Critical Function Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of multiple NETGEAR routers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the httpd service, which listens on TCP port 80 by default. The issue results from the lack of authentication prior to allowing access to system configuration information. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-13708
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202110-1807",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "rax75",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.5.132"
},
{
"model": "rax35v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "r7960p",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.4.2.84"
},
{
"model": "ex3800",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.94"
},
{
"model": "r6400",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.1.76"
},
{
"model": "r7100lg",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.72"
},
{
"model": "v6510-1fxaus",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.80"
},
{
"model": "rax80",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.5.132"
},
{
"model": "xr300",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.3.68"
},
{
"model": "raxe500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.8.70"
},
{
"model": "ex3700",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.94"
},
{
"model": "rs400",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.5.1.80"
},
{
"model": "r6700v3",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.120"
},
{
"model": "wndr3400v3",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.1.42"
},
{
"model": "d6400",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.108"
},
{
"model": "rax38v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "r8000p",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.4.2.84"
},
{
"model": "r6400v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.120"
},
{
"model": "d6220",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.76"
},
{
"model": "ms80",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.1.6.10"
},
{
"model": "rax48",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "wnr3500lv2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.2.0.70"
},
{
"model": "xr1000",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.64"
},
{
"model": "rax50",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "r8500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.2.156"
},
{
"model": "rax40v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "r8000",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.76"
},
{
"model": "r6900p",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.3.3.148"
},
{
"model": "dc112a",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.62"
},
{
"model": "mr60",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.1.6.122"
},
{
"model": "ex7500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.1.76"
},
{
"model": "rax43",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "ex7000",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.1.106"
},
{
"model": "d7000v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.76"
},
{
"model": "dgn2200v4",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.126"
},
{
"model": "r7000",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.11.128"
},
{
"model": "ms60",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.1.6.122"
},
{
"model": "ex6120",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.66"
},
{
"model": "r7900p",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.4.2.84"
},
{
"model": "rax15",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "rax45",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "lax20",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.1.6.30"
},
{
"model": "rax50s",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "rax42",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "r7850",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.5.76"
},
{
"model": "raxe450",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.8.70"
},
{
"model": "ex6130",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.46"
},
{
"model": "r7000p",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.3.3.148"
},
{
"model": "rax20",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.4.100"
},
{
"model": "r8300",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.2.156"
},
{
"model": "mr80",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.1.6.10"
},
{
"model": "rax200",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.5.132"
},
{
"model": "d6220",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ex3700",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "xr300",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ex6120",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ms60",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ex7500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "xr1000",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ex6130",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "r6400",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "d6400",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "lax20",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "mr80",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "dc112a",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ex3800",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ex7000",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "d7000v2",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "dgn2200v4",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "ms80",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "mr60",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "v6510-1fxaus",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "multiple routers",
"scope": null,
"trust": 0.7,
"vendor": "netgear",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sungur Labs",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"db": "CNNVD",
"id": "CNNVD-202110-2191"
}
],
"trust": 1.3
},
"cve": "CVE-2021-34983",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "zdi-disclosures@trendmicro.com",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2021-34983",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2021-021935",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2021-34983",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "zdi-disclosures@trendmicro.com",
"id": "CVE-2021-34983",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2021-021935",
"trust": 0.8,
"value": "Medium"
},
{
"author": "ZDI",
"id": "CVE-2021-34983",
"trust": 0.7,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202110-2191",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"db": "CNNVD",
"id": "CNNVD-202110-2191"
},
{
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "NETGEAR Multiple Routers httpd Missing Authentication for Critical Function Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of multiple NETGEAR routers. Authentication is not required to exploit this vulnerability. \n\nThe specific flaw exists within the httpd service, which listens on TCP port 80 by default. The issue results from the lack of authentication prior to allowing access to system configuration information. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. Was ZDI-CAN-13708",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-34983"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"db": "ZDI",
"id": "ZDI-21-1275"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-34983",
"trust": 3.9
},
{
"db": "ZDI",
"id": "ZDI-21-1275",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2021-021935",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-13708",
"trust": 0.7
},
{
"db": "CNNVD",
"id": "CNNVD-202110-2191",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"db": "CNNVD",
"id": "CNNVD-202110-2191"
},
{
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"id": "VAR-202110-1807",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.42902259035714285
},
"last_update_date": "2025-08-20T23:06:15.645000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "NETGEAR has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://kb.netgear.com/000064313/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Extenders-Routers-and-DSL-Modem-Routers-PSV-2021-0159"
},
{
"title": "Netgear NETGEAR Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=167951"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"db": "CNNVD",
"id": "CNNVD-202110-2191"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.0
},
{
"problemtype": "Lack of authentication for critical features (CWE-306) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://kb.netgear.com/000064313/security-advisory-for-pre-authentication-buffer-overflow-on-some-extenders-routers-and-dsl-modem-routers-psv-2021-0159"
},
{
"trust": 2.4,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-1275/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-34983"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"db": "CNNVD",
"id": "CNNVD-202110-2191"
},
{
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"db": "CNNVD",
"id": "CNNVD-202110-2191"
},
{
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-10-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"date": "2025-08-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"date": "2021-10-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202110-2191"
},
{
"date": "2024-05-07T23:15:13.573000",
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-10-29T00:00:00",
"db": "ZDI",
"id": "ZDI-21-1275"
},
{
"date": "2025-08-18T05:10:00",
"db": "JVNDB",
"id": "JVNDB-2021-021935"
},
{
"date": "2021-11-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202110-2191"
},
{
"date": "2025-08-14T01:40:56.983000",
"db": "NVD",
"id": "CVE-2021-34983"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerability related to lack of authentication for important functions in multiple NETGEAR products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-021935"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202110-2191"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…