VAR-202104-0672
Vulnerability from variot - Updated: 2024-08-14 15:27Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions. Dell Unisphere for PowerMax Exists in a vulnerability related to incorrect resource movement between regions.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). A security vulnerability exists in PowerMax that could allow an attacker to bypass restrictions through Dell Unisphere's PowerMax monitoring role to escalate privileges
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202104-0672",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "solutions enabler",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.1.6"
},
{
"model": "unisphere for powermax virtual appliance",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.1.0"
},
{
"model": "solutions enabler virtual appliance",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.1.1"
},
{
"model": "solutions enabler",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.0"
},
{
"model": "powermax os",
"scope": "eq",
"trust": 1.0,
"vendor": "dell",
"version": "5978"
},
{
"model": "solutions enabler virtual appliance",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.0"
},
{
"model": "unisphere for powermax virtual appliance",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.1.6"
},
{
"model": "unisphere for powermax virtual appliance",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "9.1.0.26"
},
{
"model": "unisphere for powermax",
"scope": "gte",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.1.0"
},
{
"model": "unisphere for powermax",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "9.1.0.26"
},
{
"model": "solutions enabler",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "9.1.0.15"
},
{
"model": "unisphere for powermax",
"scope": "lte",
"trust": 1.0,
"vendor": "dell",
"version": "9.2.1.6"
},
{
"model": "solutions enabler virtual appliance",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "9.1.0.15"
},
{
"model": "dell unisphere for powermax",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell unisphere for powermax virtual appliance",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell solutions enabler",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell solutions enabler virtual appliance",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell powermax os",
"scope": null,
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"cve": "CVE-2021-21531",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2021-21531",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-379935",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-21531",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2021-21531",
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-21531",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-21531",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2021-21531",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2021-21531",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202103-1551",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-379935",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2021-21531",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-379935"
},
{
"db": "VULMON",
"id": "CVE-2021-21531"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-1551"
},
{
"db": "NVD",
"id": "CVE-2021-21531"
},
{
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Unisphere for PowerMax versions prior to 9.2.1.6 contain an Authorization Bypass Vulnerability. A local authenticated malicious user with monitor role may exploit this vulnerability to perform unauthorized actions. Dell Unisphere for PowerMax Exists in a vulnerability related to incorrect resource movement between regions.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. DELL Dell EMC Unisphere for PowerMax is a set of graphical management tools for PowerMax storage arrays developed by Dell (DELL). A security vulnerability exists in PowerMax that could allow an attacker to bypass restrictions through Dell Unisphere\u0027s PowerMax monitoring role to escalate privileges",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-21531"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "VULHUB",
"id": "VHN-379935"
},
{
"db": "VULMON",
"id": "CVE-2021-21531"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-21531",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2021-006445",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202103-1551",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-379935",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2021-21531",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-379935"
},
{
"db": "VULMON",
"id": "CVE-2021-21531"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-1551"
},
{
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"id": "VAR-202104-0672",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-379935"
}
],
"trust": 0.58051947
},
"last_update_date": "2024-08-14T15:27:47.088000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "DSA-2021-063",
"trust": 0.8,
"url": "https://www.dell.com/support/kbdoc/000184565"
},
{
"title": "PowerMax Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145434"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-1551"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-669",
"trust": 1.1
},
{
"problemtype": "CWE-602",
"trust": 1.0
},
{
"problemtype": "Incorrect resource movement between regions (CWE-669) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-379935"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.dell.com/support/kbdoc/000184565"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-21531"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/dell-unisphere-for-powermax-privilege-escalation-via-monitor-role-34946"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/669.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-379935"
},
{
"db": "VULMON",
"id": "CVE-2021-21531"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-1551"
},
{
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-379935"
},
{
"db": "VULMON",
"id": "CVE-2021-21531"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-1551"
},
{
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-30T00:00:00",
"db": "VULHUB",
"id": "VHN-379935"
},
{
"date": "2021-04-30T00:00:00",
"db": "VULMON",
"id": "CVE-2021-21531"
},
{
"date": "2022-01-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"date": "2021-03-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-1551"
},
{
"date": "2021-04-30T21:15:08.673000",
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-05-10T00:00:00",
"db": "VULHUB",
"id": "VHN-379935"
},
{
"date": "2021-05-10T00:00:00",
"db": "VULMON",
"id": "CVE-2021-21531"
},
{
"date": "2022-01-06T08:32:00",
"db": "JVNDB",
"id": "JVNDB-2021-006445"
},
{
"date": "2021-05-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-1551"
},
{
"date": "2021-05-10T14:07:37.923000",
"db": "NVD",
"id": "CVE-2021-21531"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-1551"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u00a0Unisphere\u00a0for\u00a0PowerMax\u00a0 Vulnerability regarding incorrect resource movement between regions in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-006445"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-1551"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.