VAR-202102-0394

Vulnerability from variot - Updated: 2024-11-23 22:11

Sensitive Cookie in HTTPS Session Without 'Secure' Attribute vulnerability in (GTA) GoToAppliance of Secomea GateManager could allow an attacker to gain access to sensitive cookies. This issue affects: Secomea GateManager all versions prior to 9.3. plural GateManager The product contains a vulnerability regarding the lack of encryption of critical data.Information may be obtained. Secomea GateManager is a remote access server product of Secomea, Denmark

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0394",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "gatemanager 9250",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "secomea",
        "version": "*"
      },
      {
        "model": "gatemanager 8250",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "secomea",
        "version": "9.3"
      },
      {
        "model": "gatemanager 4260",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "secomea",
        "version": "*"
      },
      {
        "model": "gatemanager 4250",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "secomea",
        "version": "*"
      },
      {
        "model": "gatemanager 4250",
        "scope": null,
        "trust": 0.8,
        "vendor": "b r industrial automation",
        "version": null
      },
      {
        "model": "gatemanager 4260",
        "scope": null,
        "trust": 0.8,
        "vendor": "b r industrial automation",
        "version": null
      },
      {
        "model": "gatemanager 8250",
        "scope": null,
        "trust": 0.8,
        "vendor": "b r industrial automation",
        "version": null
      },
      {
        "model": "gatemanager 9250",
        "scope": null,
        "trust": 0.8,
        "vendor": "b r industrial automation",
        "version": null
      },
      {
        "model": "gatemanager",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "secomea",
        "version": "9.3"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "cve": "CVE-2020-29024",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-29024",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-18013",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-29024",
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2020-29024",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-29024",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "VulnerabilityReporting@secomea.com",
            "id": "CVE-2020-29024",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-29024",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-18013",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202102-1220",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute vulnerability in (GTA) GoToAppliance of Secomea GateManager could allow an attacker to gain access to sensitive cookies. This issue affects: Secomea GateManager all versions prior to 9.3. plural GateManager The product contains a vulnerability regarding the lack of encryption of critical data.Information may be obtained. Secomea GateManager is a remote access server product of Secomea, Denmark",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-29024",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "id": "VAR-202102-0394",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      }
    ],
    "trust": 0.9183760599999999
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:11:08.018000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "RD-2418",
        "trust": 0.8,
        "url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
      },
      {
        "title": "Patch for Secomea GateManager has an unspecified vulnerability (CNVD-2021-18013)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/253276"
      },
      {
        "title": "HTTPS  and Secomea GateManager Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=142417"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-311",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-614",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of encryption of critical data (CWE-311) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29024"
      },
      {
        "trust": 1.6,
        "url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "date": "2021-04-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "date": "2021-02-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      },
      {
        "date": "2021-02-16T16:15:12.800000",
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-18013"
      },
      {
        "date": "2021-04-02T05:27:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      },
      {
        "date": "2021-03-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      },
      {
        "date": "2024-11-21T05:23:32.413000",
        "db": "NVD",
        "id": "CVE-2020-29024"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0GateManager\u00a0 Vulnerability in lack of encryption of critical data in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-011436"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-1220"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…