VAR-202101-0139

Vulnerability from variot - Updated: 2024-11-23 20:33

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0139",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-300x408\u003cv4.1.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-15800",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2020-15800",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02595",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-15800",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-15800",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-15800",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-15800",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02595",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-915",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-15800",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-139628",
        "trust": 2.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-05",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0127",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "id": "VAR-202101-0139",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ],
    "trust": 1.2641418511111109
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ]
  },
  "last_update_date": "2024-11-23T20:33:26.845000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-139628",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "title": "Patch for Scalance X Products heap buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/244021"
      },
      {
        "title": "Siemens SCALANCE X-200IRT Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138843"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15800"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0127/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "date": "2021-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "date": "2021-01-12T21:15:16.480000",
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "date": "2021-10-01T08:52:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      },
      {
        "date": "2024-11-21T05:06:12.450000",
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Out-of-bounds write vulnerability in switch family",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.