VAR-202011-1248
Vulnerability from variot - Updated: 2024-11-23 21:51Uncontrolled resource consumption vulnerability in Ethernet Port on MELSEC iQ-R, Q and L series CPU modules (R 00/01/02 CPU firmware versions '20' and earlier, R 04/08/16/32/120 (EN) CPU firmware versions '52' and earlier, R 08/16/32/120 SFCPU firmware versions '22' and earlier, R 08/16/32/120 PCPU all versions, R 08/16/32/120 PSFCPU all versions, R 16/32/64 MTCPU all versions, Q03 UDECPU, Q 04/06/10/13/20/26/50/100 UDEHCPU serial number '22081' and earlier , Q 03/04/06/13/26 UDVCPU serial number '22031' and earlier, Q 04/06/13/26 UDPVCPU serial number '22031' and earlier, Q 172/173 DCPU all versions, Q 172/173 DSCPU all versions, Q 170 MCPU all versions, Q 170 MSCPU all versions, L 02/06/26 CPU (-P) and L 26 CPU - (P) BT all versions) allows a remote unauthenticated attacker to stop the Ethernet communication functions of the products via a specially crafted packet, which may lead to a denial of service (DoS) condition . Provided by Mitsubishi Electric Corporation MELSEC iQ-R , Q and L Of the series CPU The unit has a resource exhaustion vulnerability. (CWE-400) exists. This vulnerability information is provided by the developer for the purpose of dissemination to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developer.When a packet crafted by a remote third party is received, Ethernet Communications disrupt service operations (DoS) may become a state. A reset is required for recovery
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202011-1248",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "melsec q-q10udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec q-q13udpvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec iq-r01cpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "20"
},
{
"model": "melsec iq-r32pcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec iq-r120encpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "52"
},
{
"model": "melsec iq-r08psfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q06udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec iq-r08encpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "52"
},
{
"model": "melsec q-q03udvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec q-q04udvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec q-q26udvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec iq-r32psfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q03udecpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec l26cpu-pbt",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q173dscpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q173dcpu-s1",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec l06cpu-p",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q13udvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec iq-r120psfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q04udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec q-q13udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec iq-r120pcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q26udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec iq-r04encpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "52"
},
{
"model": "melsec q-q100udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec q-qmr-mq100",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec l26cpu-p",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec iq-r16encpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "52"
},
{
"model": "melsec iq-r00cpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "20"
},
{
"model": "melsec q-q04udpvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec iq-r32mtcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q170mscpu-s1",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q26udpvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec q-q172dcpu-s1",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec l02cpu-p",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec iq-r32sfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22"
},
{
"model": "melsec q-q172dscpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q06udpvcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22031"
},
{
"model": "melsec iq-r08pcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec iq-r16sfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22"
},
{
"model": "melsec iq-r02cpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "20"
},
{
"model": "melsec q-q50udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec iq-r32encpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "52"
},
{
"model": "melsec iq-r64mtcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec iq-r16mtcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec iq-r08sfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22"
},
{
"model": "melsec iq-r16psfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q170mcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec iq-r120sfcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22"
},
{
"model": "melsec iq-r16pcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": null
},
{
"model": "melsec q-q20udehcpu",
"scope": "eq",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "22081"
},
{
"model": "melsec l \u30b7\u30ea\u30fc\u30ba",
"scope": null,
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": null
},
{
"model": "melsec q \u30b7\u30ea\u30fc\u30ba",
"scope": null,
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": null
},
{
"model": "melsec iq-r \u30b7\u30ea\u30fc\u30ba",
"scope": null,
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mitsubishi Electric reported this vulnerability to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
}
],
"trust": 0.6
},
"cve": "CVE-2020-5652",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-5652",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2020-5652",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-009428",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-5652",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "IPA",
"id": "JVNDB-2020-009428",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202010-1668",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
},
{
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Uncontrolled resource consumption vulnerability in Ethernet Port on MELSEC iQ-R, Q and L series CPU modules (R 00/01/02 CPU firmware versions \u002720\u0027 and earlier, R 04/08/16/32/120 (EN) CPU firmware versions \u002752\u0027 and earlier, R 08/16/32/120 SFCPU firmware versions \u002722\u0027 and earlier, R 08/16/32/120 PCPU all versions, R 08/16/32/120 PSFCPU all versions, R 16/32/64 MTCPU all versions, Q03 UDECPU, Q 04/06/10/13/20/26/50/100 UDEHCPU serial number \u002722081\u0027 and earlier , Q 03/04/06/13/26 UDVCPU serial number \u002722031\u0027 and earlier, Q 04/06/13/26 UDPVCPU serial number \u002722031\u0027 and earlier, Q 172/173 DCPU all versions, Q 172/173 DSCPU all versions, Q 170 MCPU all versions, Q 170 MSCPU all versions, L 02/06/26 CPU (-P) and L 26 CPU - (P) BT all versions) allows a remote unauthenticated attacker to stop the Ethernet communication functions of the products via a specially crafted packet, which may lead to a denial of service (DoS) condition . Provided by Mitsubishi Electric Corporation MELSEC iQ-R , Q and L Of the series CPU The unit has a resource exhaustion vulnerability. (CWE-400) exists. This vulnerability information is provided by the developer for the purpose of dissemination to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developer.When a packet crafted by a remote third party is received, Ethernet Communications disrupt service operations (DoS) may become a state. A reset is required for recovery",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-5652"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "VULMON",
"id": "CVE-2020-5652"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-5652",
"trust": 3.3
},
{
"db": "JVN",
"id": "JVNVU96558207",
"trust": 2.5
},
{
"db": "ICS CERT",
"id": "ICSA-20-303-01",
"trust": 1.4
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009428",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2020.3753",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202010-1668",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-5652",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2020-5652"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
},
{
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"id": "VAR-202011-1248",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2024-11-23T21:51:08.688000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "MELSEC\u00a0iQ-R , Q\u00a0 and \u00a0L\u00a0 series \u00a0CPU\u00a0 Of the unit \u00a0Ethernet\u00a0 Denial of service on port \u00a0(DoS)\u00a0 Vulnerability",
"trust": 0.8,
"url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-013.pdf"
},
{
"title": "Multiple Mitsubishi Electric Product resource management error vulnerability fixes",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=133994"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-400",
"trust": 1.0
},
{
"problemtype": "Resource exhaustion (CWE-400) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://jvn.jp/vu/jvnvu96558207/index.html"
},
{
"trust": 1.7,
"url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-013.pdf"
},
{
"trust": 1.7,
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-013_en.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-5652"
},
{
"trust": 1.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-303-01"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu96558207"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.3753/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2020-5652"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
},
{
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2020-5652"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
},
{
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-02T00:00:00",
"db": "VULMON",
"id": "CVE-2020-5652"
},
{
"date": "2020-11-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"date": "2020-10-29T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-1668"
},
{
"date": "2020-11-02T21:15:33.697000",
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-19T00:00:00",
"db": "VULMON",
"id": "CVE-2020-5652"
},
{
"date": "2024-09-06T06:44:00",
"db": "JVNDB",
"id": "JVNDB-2020-009428"
},
{
"date": "2022-01-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202010-1668"
},
{
"date": "2024-11-21T05:34:25.693000",
"db": "NVD",
"id": "CVE-2020-5652"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Made by Mitsubishi Electric \u00a0MELSEC\u00a0iQ-R , Q\u00a0 and \u00a0L\u00a0 Resource exhaustion vulnerability in the series",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009428"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "resource management error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202010-1668"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.