VAR-202009-0589
Vulnerability from variot - Updated: 2025-06-05 23:07Philips Clinical Collaboration Platform, Versions 12.2.1 and prior,
does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources. Clinical Collaboration Platform Is Philips This is a medical image information system provided by the company. Clinical Collaboration Platform Is vulnerable to several vulnerabilities: * Cross-site request forgery (CWE-352) - CVE-2020-14506 *Web Improperly invalidating scripts in page tag attributes (CWE-83) - CVE-2020-14525 * Malfunction of protection mechanism (CWE-693) - CVE-2020-16198 * Algorithm downgrade (CWE-757) - CVE-2020-16200 * Environmental setting (CWE-16) - CVE-2020-16247The expected impact depends on each vulnerability, but it may be affected as follows. * When a user who logs in to the product accesses a specially crafted page, he / she is forced to perform an unintended operation. - CVE-2020-14506 * Arbitrary script is executed by the user who logged in to the product - CVE-2020-14525 * Authentication is bypassed and unauthorized access is made by an adjacent third party - CVE-2020-16198 * Adjacent third parties cause resource exhaustion and disrupt service operations (DoS) Be in a state - CVE-2020-16200 * Unauthorized access to sensitive information by a third party - CVE-2020-16247. Attackers can use this vulnerability to exhaust available resources
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202009-0589",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "clinical collaboration platform",
"scope": "lte",
"trust": 1.0,
"vendor": "philips",
"version": "12.2.1"
},
{
"model": "clinical collaboration platform",
"scope": "eq",
"trust": 0.8,
"vendor": "philips",
"version": "12.2.1"
},
{
"model": "clinical collaboration platform",
"scope": "lte",
"trust": 0.6,
"vendor": "philips",
"version": "\u003c=12.2.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:philips:clinical_collaboration_platform",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
}
]
},
"cve": "CVE-2020-16200",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CVE-2020-16200",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.0,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2020-52880",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "VHN-169255",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2020-16200",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA score",
"availabilityImpact": "None",
"baseScore": 3.4,
"baseSeverity": "Low",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2020-008764",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "IPA score",
"availabilityImpact": "None",
"baseScore": 3.5,
"baseSeverity": "Low",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2020-008764",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "High",
"attackVector": "Adjacent Network",
"author": "IPA score",
"availabilityImpact": "Low",
"baseScore": 5.0,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2020-008764",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-008764",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 6.8,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-008764",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "IPA",
"id": "JVNDB-2020-008764",
"trust": 2.4,
"value": "Medium"
},
{
"author": "IPA",
"id": "JVNDB-2020-008764",
"trust": 1.6,
"value": "Low"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2020-16200",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "ics-cert@hq.dhs.gov",
"id": "CVE-2020-16200",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2020-52880",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-169255",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "VULHUB",
"id": "VHN-169255"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "NVD",
"id": "CVE-2020-16200"
},
{
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, \n\ndoes not properly control the allocation and maintenance of a limited \nresource, thereby enabling an attacker to influence the amount of \nresources consumed, eventually leading to the exhaustion of available \nresources. Clinical Collaboration Platform Is Philips This is a medical image information system provided by the company. Clinical Collaboration Platform Is vulnerable to several vulnerabilities: * Cross-site request forgery (CWE-352) - CVE-2020-14506 *Web Improperly invalidating scripts in page tag attributes (CWE-83) - CVE-2020-14525 * Malfunction of protection mechanism (CWE-693) - CVE-2020-16198 * Algorithm downgrade (CWE-757) - CVE-2020-16200 * Environmental setting (CWE-16) - CVE-2020-16247The expected impact depends on each vulnerability, but it may be affected as follows. * When a user who logs in to the product accesses a specially crafted page, he / she is forced to perform an unintended operation. - CVE-2020-14506 * Arbitrary script is executed by the user who logged in to the product - CVE-2020-14525 * Authentication is bypassed and unauthorized access is made by an adjacent third party - CVE-2020-16198 * Adjacent third parties cause resource exhaustion and disrupt service operations (DoS) Be in a state - CVE-2020-16200 * Unauthorized access to sensitive information by a third party - CVE-2020-16247. Attackers can use this vulnerability to exhaust available resources",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-16200"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "VULHUB",
"id": "VHN-169255"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSMA-20-261-01",
"trust": 2.5
},
{
"db": "NVD",
"id": "CVE-2020-16200",
"trust": 2.5
},
{
"db": "JVN",
"id": "JVNVU94803567",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-52880",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-169255",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "VULHUB",
"id": "VHN-169255"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"id": "VAR-202009-0589",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "VULHUB",
"id": "VHN-169255"
}
],
"trust": 1.4
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
}
]
},
"last_update_date": "2025-06-05T23:07:39.495000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Product Security ",
"trust": 0.8,
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"title": "Patch for Philips Clinical Collaboration Platform algorithm downgrade vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/234886"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-757",
"trust": 1.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-169255"
},
{
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01"
},
{
"trust": 1.0,
"url": "https://www.philips.com/a-w/security/security-advisories/product-security-2020.html#2020_archive"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-16200"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-16247"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14506"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14525"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-16198"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu94803567"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "VULHUB",
"id": "VHN-169255"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"db": "VULHUB",
"id": "VHN-169255"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-09-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"date": "2020-09-18T00:00:00",
"db": "VULHUB",
"id": "VHN-169255"
},
{
"date": "2020-09-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"date": "2020-09-18T18:15:17.037000",
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-09-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-52880"
},
{
"date": "2020-09-25T00:00:00",
"db": "VULHUB",
"id": "VHN-169255"
},
{
"date": "2020-09-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-008764"
},
{
"date": "2025-06-04T22:15:23.680000",
"db": "NVD",
"id": "CVE-2020-16200"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philips Made Clinical Collaboration Platform Multiple vulnerabilities in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-008764"
}
],
"trust": 0.8
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.