VAR-202007-1235
Vulnerability from variot - Updated: 2024-11-23 21:35A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions >= V2.2 < V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation. SIMATIC S7-200 SMART CPU Is vulnerable to a resource exhaustion.Denial of service (DoS) It may be put in a state. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) of Germany's Siemens (Siemens) company used in small and medium-sized automation systems. Attackers can use vulnerabilities to cause denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202007-1235",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic s7-200 smart st cpu",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2.2"
},
{
"model": "simatic s7-200 smart sr cpu",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.5.1"
},
{
"model": "simatic s7-200 smart st cpu",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.5.1"
},
{
"model": "simatic s7-200 smart sr cpu",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2.2"
},
{
"model": "simatic s7-200 smart",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-200 smart",
"scope": "lt",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "simatic s7-200 smart firmware 2.2 that\u0027s all 2.5.1"
},
{
"model": "simatic s7-200 smart cpu family",
"scope": "gte",
"trust": 0.6,
"vendor": "siemens",
"version": "v2.2,\u003cv2.5.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"cve": "CVE-2020-7584",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-7584",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-40865",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2020-7584",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2020-7584",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-7584",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2020-7584",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2020-40865",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202007-582",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions \u003e= V2.2 \u003c V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation. SIMATIC S7-200 SMART CPU Is vulnerable to a resource exhaustion.Denial of service (DoS) It may be put in a state. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) of Germany\u0027s Siemens (Siemens) company used in small and medium-sized automation systems. Attackers can use vulnerabilities to cause denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7584"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNVD",
"id": "CNVD-2020-40865"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-7584",
"trust": 3.0
},
{
"db": "SIEMENS",
"id": "SSA-589181",
"trust": 2.2
},
{
"db": "ICS CERT",
"id": "ICSA-20-196-06",
"trust": 1.4
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-40865",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.2387",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"id": "VAR-202007-1235",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
}
],
"trust": 1.37777775
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
}
]
},
"last_update_date": "2024-11-23T21:35:29.652000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-589181",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
},
{
"title": "Patch for Denial of Service Vulnerability in Siemens SIMATIC S7-200 Smart CPU Series",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/226103"
},
{
"title": "SIMATIC S7-200 SMART SR CPU and ST CPU Remediation of resource management error vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=124357"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-400",
"trust": 1.0
},
{
"problemtype": "Resource exhaustion (CWE-400) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-7584"
},
{
"trust": 1.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-06"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-incomming-connection-32814"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.2387/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"date": "2020-08-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"date": "2020-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"date": "2020-07-14T14:15:18.650000",
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-40865"
},
{
"date": "2020-09-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007898"
},
{
"date": "2020-07-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202007-582"
},
{
"date": "2024-11-21T05:37:25.200000",
"db": "NVD",
"id": "CVE-2020-7584"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC\u00a0S7-200\u00a0SMART\u00a0CPU\u00a0 Resource Depletion Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007898"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "resource management error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202007-582"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.