VAR-202007-1228

Vulnerability from variot - Updated: 2024-11-23 22:05

TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a resource management error vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan's Mitsubishi Electric.

CoreOS Y and previous versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a resource management error vulnerability. Attackers can use this vulnerability to obtain sensitive information

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1228",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "coreos",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": "y"
      },
      {
        "model": "gt23 model",
        "scope": null,
        "trust": 0.8,
        "vendor": "mitsubishi electric",
        "version": null
      },
      {
        "model": "gt25 model",
        "scope": null,
        "trust": 0.8,
        "vendor": "mitsubishi electric",
        "version": null
      },
      {
        "model": "gt27 model",
        "scope": null,
        "trust": 0.8,
        "vendor": "mitsubishi electric",
        "version": null
      },
      {
        "model": "electric gt27 model",
        "scope": null,
        "trust": 0.6,
        "vendor": "mitsubishi",
        "version": null
      },
      {
        "model": "electric gt25 model",
        "scope": null,
        "trust": 0.6,
        "vendor": "mitsubishi",
        "version": null
      },
      {
        "model": "electric gt23 model",
        "scope": null,
        "trust": 0.6,
        "vendor": "mitsubishi",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:mitsubishielectric:gt23_model",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:mitsubishielectric:gt25_model",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:mitsubishielectric:gt27_model",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      }
    ]
  },
  "cve": "CVE-2020-5600",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-5600",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-46798",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-5600",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-006469",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-5600",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "IPA",
            "id": "JVNDB-2020-006469",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-46798",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202007-308",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a resource management error vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan\u0027s Mitsubishi Electric. \n\r\n\r\nCoreOS Y and previous versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a resource management error vulnerability. Attackers can use this vulnerability to obtain sensitive information",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-5600"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-5600",
        "trust": 3.0
      },
      {
        "db": "JVN",
        "id": "JVNVU95413676",
        "trust": 2.4
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-189-02",
        "trust": 2.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469",
        "trust": 1.4
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.2312",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "id": "VAR-202007-1228",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      }
    ],
    "trust": 1.54642855
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:05:45.626000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "GOT2000\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3051\u308bTCP/IP\u30b9\u30bf\u30c3\u30af\u306e\u8907\u6570\u306e\u8106\u5f31\u6027",
        "trust": 0.8,
        "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-005.pdf"
      },
      {
        "title": "Patch for Resource management errors and vulnerabilities in multiple Mitsubishi Electric products (CNVD-2020-46798)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/231124"
      },
      {
        "title": "Multiple Mitsubishi Electric Product resource management error vulnerability fixes",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=124077"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-476",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-384",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-399",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-88",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-284",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.0,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02"
      },
      {
        "trust": 1.6,
        "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-005_en.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://jvn.jp/en/vu/jvnvu95413676/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5598"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5599"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5600"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5595"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5596"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5597"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu95413676/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-006469.html"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5600"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.2312/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "date": "2020-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "date": "2020-07-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      },
      {
        "date": "2020-07-07T09:15:10.450000",
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-46798"
      },
      {
        "date": "2020-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      },
      {
        "date": "2020-07-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      },
      {
        "date": "2024-11-21T05:34:20.490000",
        "db": "NVD",
        "id": "CVE-2020-5600"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Made by Mitsubishi Electric  GOT2000 Of the series  TCP/IP Multiple vulnerabilities in functionality",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006469"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-308"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour