VAR-202004-1711
Vulnerability from variot - Updated: 2024-11-23 22:41Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40 and R9000 before 1.0.3.6. NETGEAR R7800 and R9000 The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Both NETGEAR R9000 and NETGEAR R7800 are wireless routers from NETGEAR. The vulnerability stems from the fact that when the network system or product performs operations on the memory, the data boundary is not correctly verified, resulting in incorrect read and write operations to other associated memory locations. Attackers can use this vulnerability to cause buffer overflow or heap overflow. This affects R7800 prior to 1.0.2.40 and R9000 prior to 1.0.3.6
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-1711",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "r7800",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.40"
},
{
"model": "r9000",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.3.6"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.2.40"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.3.6"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.16"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.28"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.30"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.32"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.36"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.38"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.4"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.30"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.40"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.52"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"db": "VULMON",
"id": "CVE-2018-21200"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:netgear:r7800_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r9000_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
}
]
},
"cve": "CVE-2018-21200",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CVE-2018-21200",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.1,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Adjacent Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.2,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2018-016349",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CNVD-2021-46352",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2018-21200",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "cve@mitre.org",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2018-21200",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.8,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2018-016349",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-21200",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "cve@mitre.org",
"id": "CVE-2018-21200",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "JVNDB-2018-016349",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-46352",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202004-2266",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2018-21200",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"db": "VULMON",
"id": "CVE-2018-21200"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2266"
},
{
"db": "NVD",
"id": "CVE-2018-21200"
},
{
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40 and R9000 before 1.0.3.6. NETGEAR R7800 and R9000 The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Both NETGEAR R9000 and NETGEAR R7800 are wireless routers from NETGEAR. The vulnerability stems from the fact that when the network system or product performs operations on the memory, the data boundary is not correctly verified, resulting in incorrect read and write operations to other associated memory locations. Attackers can use this vulnerability to cause buffer overflow or heap overflow. This affects R7800 prior to 1.0.2.40 and R9000 prior to 1.0.3.6",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-21200"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"db": "VULMON",
"id": "CVE-2018-21200"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-21200",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-46352",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2266",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2018-21200",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"db": "VULMON",
"id": "CVE-2018-21200"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2266"
},
{
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"id": "VAR-202004-1711",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
}
],
"trust": 1.0224239549999998
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
}
]
},
"last_update_date": "2024-11-23T22:41:06.337000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security Advisory for Post-Authentication Stack Overflow on Some Routers, PSV-2017-2592",
"trust": 0.8,
"url": "https://kb.netgear.com/000055149/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-PSV-2017-2592"
},
{
"title": "Patch for NETGEAR R9000 and R7800 buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/275826"
},
{
"title": "NETGEAR R9000 and R7800 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117358"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2266"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-21200"
},
{
"trust": 1.7,
"url": "https://kb.netgear.com/000055149/security-advisory-for-post-authentication-stack-overflow-on-some-routers-psv-2017-2592"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-21200"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"db": "VULMON",
"id": "CVE-2018-21200"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2266"
},
{
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"db": "VULMON",
"id": "CVE-2018-21200"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2266"
},
{
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-06-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"date": "2020-04-28T00:00:00",
"db": "VULMON",
"id": "CVE-2018-21200"
},
{
"date": "2020-06-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"date": "2020-04-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-2266"
},
{
"date": "2020-04-28T16:15:13.217000",
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-07-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-46352"
},
{
"date": "2020-05-01T00:00:00",
"db": "VULMON",
"id": "CVE-2018-21200"
},
{
"date": "2020-06-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016349"
},
{
"date": "2020-05-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-2266"
},
{
"date": "2024-11-21T04:03:09.540000",
"db": "NVD",
"id": "CVE-2018-21200"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-2266"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "NETGEAR R7800 and R9000 Out-of-bounds write vulnerabilities in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016349"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-2266"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.