VAR-202004-1696
Vulnerability from variot - Updated: 2024-11-23 21:51Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62. plural NETGEAR The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R7500, etc. are all products of NETGEAR. NETGEAR R7500 is a wireless router. NETGEAR D6100 is a wireless modem. NETGEAR WNDR3700 is a wireless router. The vulnerability stems from the fact that the network system or product performs an operation on the memory, and the data boundary is not correctly verified, resulting in an incorrect read and write operation to other associated memory locations. The attacker The vulnerability can be exploited to cause buffer overflow or heap overflow. This affects D6100 prior to 1.0.0.57, D7800 prior to 1.0.1.34, R7500 prior to 1.0.0.122, R7500v2 prior to 1.0.3.24, R7800 prior to 1.0.2.40, R9000 prior to 1.0.2.52, WNDR3700v4 prior to 1.0.2.92, WNDR4300 prior to 1.0.2.94, WNDR4300v2 prior to 1.0.0.50, WNDR4500v3 prior to 1.0.0.50, and WNR2000v5 prior to 1.0.0.62
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-1696",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "r7800",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.40"
},
{
"model": "r9000",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.52"
},
{
"model": "d6100",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.0.57"
},
{
"model": "r7500",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.0.122"
},
{
"model": "wndr4300",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.94"
},
{
"model": "d7800",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.1.34"
},
{
"model": "r7500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.3.24"
},
{
"model": "wndr4500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.50"
},
{
"model": "wndr4300",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.50"
},
{
"model": "wnr2000",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.62"
},
{
"model": "wndr3700",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.2.92"
},
{
"model": "d6100",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.57"
},
{
"model": "d7800",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.1.34"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.122"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.3.24"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.2.40"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.2.52"
},
{
"model": "wndr3700",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.2.92"
},
{
"model": "wndr4300",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.50"
},
{
"model": "wndr4300",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.2.94"
},
{
"model": "wndr4500",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.50"
},
{
"model": "wnr2000v5",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.0.62"
},
{
"model": "r7500v2",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.3.24"
},
{
"model": "wndr3700v4",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.2.92"
},
{
"model": "wndr4300v2",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.0.50"
},
{
"model": "wndr4500v3",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.0.50"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:netgear:d6100_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:d7800_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r7500_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r7800_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r9000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:wndr3700_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:wndr4300_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:wndr4500_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
}
]
},
"cve": "CVE-2018-21185",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CVE-2018-21185",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.1,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Adjacent Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.2,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2018-016378",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CNVD-2020-28245",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2018-21185",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "cve@mitre.org",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2018-21185",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.8,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2018-016378",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-21185",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "cve@mitre.org",
"id": "CVE-2018-21185",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "JVNDB-2018-016378",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2020-28245",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202004-2244",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2018-21185",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"db": "VULMON",
"id": "CVE-2018-21185"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2244"
},
{
"db": "NVD",
"id": "CVE-2018-21185"
},
{
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.57, D7800 before 1.0.1.34, R7500 before 1.0.0.122, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.2.52, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62. plural NETGEAR The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R7500, etc. are all products of NETGEAR. NETGEAR R7500 is a wireless router. NETGEAR D6100 is a wireless modem. NETGEAR WNDR3700 is a wireless router. The vulnerability stems from the fact that the network system or product performs an operation on the memory, and the data boundary is not correctly verified, resulting in an incorrect read and write operation to other associated memory locations. The attacker The vulnerability can be exploited to cause buffer overflow or heap overflow. This affects D6100 prior to 1.0.0.57, D7800 prior to 1.0.1.34, R7500 prior to 1.0.0.122, R7500v2 prior to 1.0.3.24, R7800 prior to 1.0.2.40, R9000 prior to 1.0.2.52, WNDR3700v4 prior to 1.0.2.92, WNDR4300 prior to 1.0.2.94, WNDR4300v2 prior to 1.0.0.50, WNDR4500v3 prior to 1.0.0.50, and WNR2000v5 prior to 1.0.0.62",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-21185"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"db": "VULMON",
"id": "CVE-2018-21185"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-21185",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-28245",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2244",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2018-21185",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"db": "VULMON",
"id": "CVE-2018-21185"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2244"
},
{
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"id": "VAR-202004-1696",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
}
],
"trust": 1.2809049927272729
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
}
]
},
"last_update_date": "2024-11-23T21:51:30.196000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security Advisory for Post-Authentication Stack Overflow on Some Routers and Gateways, PSV-2017-2610",
"trust": 0.8,
"url": "https://kb.netgear.com/000055173/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-Gateways-PSV-2017-2610"
},
{
"title": "Patch for Multiple NETGEAR product buffer overflow vulnerabilities (CNVD-2020-28245)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/217475"
},
{
"title": "Multiple NETGEAR Product Buffer Error Vulnerability Fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117337"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2244"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-21185"
},
{
"trust": 1.7,
"url": "https://kb.netgear.com/000055173/security-advisory-for-post-authentication-stack-overflow-on-some-routers-and-gateways-psv-2017-2610"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-21185"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"db": "VULMON",
"id": "CVE-2018-21185"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2244"
},
{
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"db": "VULMON",
"id": "CVE-2018-21185"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2244"
},
{
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-05-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"date": "2020-04-28T00:00:00",
"db": "VULMON",
"id": "CVE-2018-21185"
},
{
"date": "2020-06-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"date": "2020-04-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-2244"
},
{
"date": "2020-04-28T13:15:12.747000",
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-05-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-28245"
},
{
"date": "2020-05-06T00:00:00",
"db": "VULMON",
"id": "CVE-2018-21185"
},
{
"date": "2020-06-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016378"
},
{
"date": "2020-05-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-2244"
},
{
"date": "2024-11-21T04:03:07.177000",
"db": "NVD",
"id": "CVE-2018-21185"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-2244"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural NETGEAR Out-of-bounds write vulnerabilities in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016378"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-2244"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.