VAR-202004-1683
Vulnerability from variot - Updated: 2024-11-23 22:29Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, R6700 before 1.0.1.30, R6700v2 before 1.2.0.16, R6800 before 1.2.0.16, R6900 before 1.0.1.30, R6900P before 1.2.0.22, R6900v2 before 1.2.0.16, R7000 before 1.0.9.12, R7000P before 1.2.0.22, R7500v2 before 1.0.3.20, R7800 before 1.0.2.44, R8300 before 1.0.2.106, R8500 before 1.0.2.106, and R9000 before 1.0.2.52. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR D7800, etc. are all products of NETGEAR. NETGEAR D7800 is a wireless modem. NETGEAR D7000 is a wireless modem. NETGEAR R6900 is a wireless router. The vulnerability stems from the fact that the network system or product does not correctly filter the special characters, commands, etc. in the process of constructing the executable command of the operating system by external input data. Attackers can use this vulnerability to execute illegal operating system commands. This affects D7000 prior to 1.0.1.60, D7800 prior to 1.0.1.34, D8500 prior to 1.0.3.39, R6700 prior to 1.0.1.30, R6700v2 prior to 1.2.0.16, R6800 prior to 1.2.0.16, R6900 prior to 1.0.1.30, R6900P prior to 1.2.0.22, R6900v2 prior to 1.2.0.16, R7000 prior to 1.0.9.12, R7000P prior to 1.2.0.22, R7500v2 prior to 1.0.3.20, R7800 prior to 1.0.2.44, R8300 prior to 1.0.2.106, R8500 prior to 1.0.2.106, and R9000 prior to 1.0.2.52
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-1683",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "r9000",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.52"
},
{
"model": "r8500",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.106"
},
{
"model": "r8300",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.106"
},
{
"model": "r7000p",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.2.0.22"
},
{
"model": "r6900p",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.2.0.22"
},
{
"model": "d7800",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.1.34"
},
{
"model": "d7000",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.1.60"
},
{
"model": "d8500",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.3.39"
},
{
"model": "r6700",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.1.30"
},
{
"model": "r6800",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "r6900",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.1.30"
},
{
"model": "r7000",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.9.12"
},
{
"model": "r7800",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.2.44"
},
{
"model": "r7500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.3.20"
},
{
"model": "r6700",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "r6900",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.9,
"vendor": "netgear",
"version": "1.0.1.30"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.9,
"vendor": "netgear",
"version": "1.0.1.30"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.1.60"
},
{
"model": "d7800",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.1.34"
},
{
"model": "d8500",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.3.39"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "r6900p",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.2.0.22"
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.9.12"
},
{
"model": "r7500v2",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.3.20"
},
{
"model": "r6700v2",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "r6900v2",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.2.0.16"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.38"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.44"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.51"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.52"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.53"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.74"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.50"
},
{
"model": "d7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.52"
},
{
"model": "d7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.22"
},
{
"model": "d7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.24"
},
{
"model": "d7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.28"
},
{
"model": "d7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.30"
},
{
"model": "d7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.31"
},
{
"model": "d8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "d8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.3.27"
},
{
"model": "d8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.3.28"
},
{
"model": "d8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.3.29"
},
{
"model": "d8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.3.35"
},
{
"model": "d8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.3.36"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.14"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.16"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.20"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.22"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.26"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.36"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.44"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.46"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.48"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.6"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.8"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.32"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.52"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.66"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.4.84"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.1.0.38"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.1.0.42"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.1.1.20"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.2"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.4"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.12"
},
{
"model": "r6700",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.14"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.10"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.1.0.38"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.1.0.42"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.2"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.4"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.12"
},
{
"model": "r6800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.14"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.14"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.16"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.20"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.22"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.26"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.28"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.34"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.44"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.46"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.48"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.4"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.8"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.1.0.42"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.2"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.4"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.12"
},
{
"model": "r6900",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.2.0.14"
},
{
"model": "r6900p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r6900p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.56"
},
{
"model": "r6900p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.58"
},
{
"model": "r6900p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.62"
},
{
"model": "r6900p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.16"
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.7.2 1.1.93"
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.7.10"
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.9.4"
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.9.6"
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.9.10"
},
{
"model": "r7000p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r7000p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.56"
},
{
"model": "r7000p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.58"
},
{
"model": "r7000p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.62"
},
{
"model": "r7000p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.86"
},
{
"model": "r7000p",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.1.16"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.108"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.110"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.112"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.116"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.118"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.122"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.124"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.0.130"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.3.10"
},
{
"model": "r7500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.3.16"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.16"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.28"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.30"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.32"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.36"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.38"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.40"
},
{
"model": "r7800",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.42"
},
{
"model": "r8300",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r8300",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.74"
},
{
"model": "r8300",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.86"
},
{
"model": "r8300",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.94"
},
{
"model": "r8300",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.100 1.0.82"
},
{
"model": "r8300",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.104"
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.74"
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.86"
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.94"
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.100"
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.100 1.0.82"
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.104"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": null
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.4"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.30"
},
{
"model": "r9000",
"scope": "eq",
"trust": 0.1,
"vendor": "netgear",
"version": "1.0.2.40"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"db": "VULMON",
"id": "CVE-2018-21225"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:netgear:d7000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:d7800_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:d8500_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r6700_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r6800_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r6900_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r6900p_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r7000_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
}
]
},
"cve": "CVE-2018-21225",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CVE-2018-21225",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.1,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Adjacent Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.2,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2018-016333",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CNVD-2021-48931",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2018-21225",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "cve@mitre.org",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2018-21225",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.8,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2018-016333",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-21225",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "cve@mitre.org",
"id": "CVE-2018-21225",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "JVNDB-2018-016333",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-48931",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202004-2320",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2018-21225",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"db": "VULMON",
"id": "CVE-2018-21225"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2320"
},
{
"db": "NVD",
"id": "CVE-2018-21225"
},
{
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7000 before 1.0.1.60, D7800 before 1.0.1.34, D8500 before 1.0.3.39, R6700 before 1.0.1.30, R6700v2 before 1.2.0.16, R6800 before 1.2.0.16, R6900 before 1.0.1.30, R6900P before 1.2.0.22, R6900v2 before 1.2.0.16, R7000 before 1.0.9.12, R7000P before 1.2.0.22, R7500v2 before 1.0.3.20, R7800 before 1.0.2.44, R8300 before 1.0.2.106, R8500 before 1.0.2.106, and R9000 before 1.0.2.52. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR D7800, etc. are all products of NETGEAR. NETGEAR D7800 is a wireless modem. NETGEAR D7000 is a wireless modem. NETGEAR R6900 is a wireless router. The vulnerability stems from the fact that the network system or product does not correctly filter the special characters, commands, etc. in the process of constructing the executable command of the operating system by external input data. Attackers can use this vulnerability to execute illegal operating system commands. This affects D7000 prior to 1.0.1.60, D7800 prior to 1.0.1.34, D8500 prior to 1.0.3.39, R6700 prior to 1.0.1.30, R6700v2 prior to 1.2.0.16, R6800 prior to 1.2.0.16, R6900 prior to 1.0.1.30, R6900P prior to 1.2.0.22, R6900v2 prior to 1.2.0.16, R7000 prior to 1.0.9.12, R7000P prior to 1.2.0.22, R7500v2 prior to 1.0.3.20, R7800 prior to 1.0.2.44, R8300 prior to 1.0.2.106, R8500 prior to 1.0.2.106, and R9000 prior to 1.0.2.52",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-21225"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"db": "VULMON",
"id": "CVE-2018-21225"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-21225",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-48931",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2320",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2018-21225",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"db": "VULMON",
"id": "CVE-2018-21225"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2320"
},
{
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"id": "VAR-202004-1683",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
}
],
"trust": 1.088492554117647
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
}
]
},
"last_update_date": "2024-11-23T22:29:38.672000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security Advisory for Post-Authentication Command Injection on Some Routers and Gateways, PSV-2017-2160",
"trust": 0.8,
"url": "https://kb.netgear.com/000055112/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2160"
},
{
"title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-48931)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/277341"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-21225"
},
{
"trust": 1.7,
"url": "https://kb.netgear.com/000055112/security-advisory-for-post-authentication-command-injection-on-some-routers-and-gateways-psv-2017-2160"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-21225"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"db": "VULMON",
"id": "CVE-2018-21225"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2320"
},
{
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"db": "VULMON",
"id": "CVE-2018-21225"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-2320"
},
{
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-07-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"date": "2020-04-28T00:00:00",
"db": "VULMON",
"id": "CVE-2018-21225"
},
{
"date": "2020-06-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"date": "2020-04-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-2320"
},
{
"date": "2020-04-28T17:15:13.163000",
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-07-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-48931"
},
{
"date": "2020-05-04T00:00:00",
"db": "VULMON",
"id": "CVE-2018-21225"
},
{
"date": "2020-06-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016333"
},
{
"date": "2020-05-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-2320"
},
{
"date": "2024-11-21T04:03:13.433000",
"db": "NVD",
"id": "CVE-2018-21225"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-2320"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural NETGEAR On the device OS Command injection vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016333"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-2320"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.