VAR-202004-1364
Vulnerability from variot - Updated: 2024-11-23 22:37Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R7000, etc. are all products of NETGEAR. NETGEAR R7000 is a wireless router. NETGEAR D3600 is a wireless modem. NETGEAR WNDR3700 is a wireless router.
Injection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-1364",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "r6100",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.1.16"
},
{
"model": "r7000",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.9.10"
},
{
"model": "r7000p",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.2.0.22"
},
{
"model": "r6900p",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.2.0.22"
},
{
"model": "d6100",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.0.57"
},
{
"model": "d3600",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.0.68"
},
{
"model": "d6000",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.0.68"
},
{
"model": "r7100lg",
"scope": "lt",
"trust": 1.6,
"vendor": "netgear",
"version": "1.0.0.40"
},
{
"model": "wndr4300",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.2.90"
},
{
"model": "wnr2000",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.58"
},
{
"model": "wndr4500",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.48"
},
{
"model": "wndr4300",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.0.48"
},
{
"model": "wndr3700",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.2.88"
},
{
"model": "d3600",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.68"
},
{
"model": "d6000",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.68"
},
{
"model": "d6100",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.57"
},
{
"model": "r6100",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.1.16"
},
{
"model": "r6900p",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.2.0.22"
},
{
"model": "r7000",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.9.10"
},
{
"model": "r7000p",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.2.0.22"
},
{
"model": "r7100lg",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.0.40"
},
{
"model": "wndr3700",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.2.88"
},
{
"model": "wndr4300",
"scope": "eq",
"trust": 0.8,
"vendor": "netgear",
"version": "1.0.2.90"
},
{
"model": "wnr2000v5",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.0.58"
},
{
"model": "wndr4500v3",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.0.48"
},
{
"model": "wndr4300v2",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.0.48"
},
{
"model": "wndr3700v4",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.2.88"
},
{
"model": "wndr4300v1",
"scope": "lt",
"trust": 0.6,
"vendor": "netgear",
"version": "1.0.2.90"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:netgear:d3600_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:d6000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:d6100_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r6100_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r6900p_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r7000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r7000p_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:r7100lg_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:wndr3700_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:netgear:wndr4300_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
}
]
},
"cve": "CVE-2017-18762",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"id": "CVE-2017-18762",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Adjacent Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2017-014903",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"id": "CNVD-2021-59159",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2017-18762",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "cve@mitre.org",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2017-18762",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2017-014903",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-18762",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "cve@mitre.org",
"id": "CVE-2017-18762",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "JVNDB-2017-014903",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2021-59159",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202004-1907",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-1907"
},
{
"db": "NVD",
"id": "CVE-2017-18762"
},
{
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R7000, etc. are all products of NETGEAR. NETGEAR R7000 is a wireless router. NETGEAR D3600 is a wireless modem. NETGEAR WNDR3700 is a wireless router. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-18762"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "CNVD",
"id": "CNVD-2021-59159"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-18762",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-59159",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202004-1907",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-1907"
},
{
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"id": "VAR-202004-1364",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
}
],
"trust": 1.2312351814285714
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
}
]
},
"last_update_date": "2024-11-23T22:37:25.063000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security Advisory for Pre-Authentication Command Injection on Some Routers and Gateways, PSV-2017-2451",
"trust": 0.8,
"url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
},
{
"title": "Patch for Injection vulnerabilities in multiple NETGEAR products (CNVD-2021-59159)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/284336"
},
{
"title": "Multiple NETGEAR Fixing measures for product injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117243"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-1907"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-74",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-18762"
},
{
"trust": 1.6,
"url": "https://kb.netgear.com/000051483/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-gateways-psv-2017-2451"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-18762"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-1907"
},
{
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-1907"
},
{
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-08-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"date": "2020-05-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"date": "2020-04-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-1907"
},
{
"date": "2020-04-22T16:15:11.373000",
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-08-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-59159"
},
{
"date": "2020-05-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014903"
},
{
"date": "2020-04-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-1907"
},
{
"date": "2024-11-21T03:20:51.437000",
"db": "NVD",
"id": "CVE-2017-18762"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-1907"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural NETGEAR Injection vulnerabilities in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014903"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-1907"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.