VAR-202003-1445
Vulnerability from variot - Updated: 2024-11-23 22:44A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service. IGSS There is a vulnerability in the lack of authentication for critical features.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric IGSS. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.The specific flaw exists within the IGSSupdateservice service, which listens on TCP port 12414 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of SYSTEM. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Monitoring System) system for monitoring and controlling industrial processes by Schneider Electric (France).
Schneider Electric IGSS (Interactive Graphical SCADA System) 14 and earlier versions (using IGSSupdate service) have access control error vulnerabilities. The vulnerability stems from network systems or products that do not properly restrict access to resources from unauthorized roles
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202003-1445",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "interactive graphical scada system",
"scope": "gte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "14.0"
},
{
"model": "interactive graphical scada system",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "14.0.0.20009"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "14"
},
{
"model": "igss",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "interactive graphical scada system",
"version": "*"
},
{
"model": "electric igss",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=14"
}
],
"sources": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:interactive_graphical_scada_system",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Anonymous",
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-370"
}
],
"trust": 0.7
},
"cve": "CVE-2020-7479",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2020-7479",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.6,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-003179",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CNVD-2020-19888",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "74948927-d328-4f80-9f7c-7522889db29e",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-185604",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2020-7479",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-003179",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2020-7479",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-7479",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "JVNDB-2020-003179",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2020-7479",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2020-19888",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202003-1340",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-185604",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "VULHUB",
"id": "VHN-185604"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
},
{
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service. IGSS There is a vulnerability in the lack of authentication for critical features.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. This vulnerability allows local attackers to escalate privileges on affected installations of Schneider Electric IGSS. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.The specific flaw exists within the IGSSupdateservice service, which listens on TCP port 12414 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to escalate privileges and execute code in the context of SYSTEM. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Monitoring System) system for monitoring and controlling industrial processes by Schneider Electric (France). \n\r\n\r\nSchneider Electric IGSS (Interactive Graphical SCADA System) 14 and earlier versions (using IGSSupdate service) have access control error vulnerabilities. The vulnerability stems from network systems or products that do not properly restrict access to resources from unauthorized roles",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7479"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "VULHUB",
"id": "VHN-185604"
}
],
"trust": 3.42
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-7479",
"trust": 4.4
},
{
"db": "ZDI",
"id": "ZDI-20-370",
"trust": 2.4
},
{
"db": "SCHNEIDER",
"id": "SEVD-2020-070-01",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-20-084-02",
"trust": 1.4
},
{
"db": "CNVD",
"id": "CNVD-2020-19888",
"trust": 1.3
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340",
"trust": 1.3
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-9758",
"trust": 0.7
},
{
"db": "NSFOCUS",
"id": "46227",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.1085",
"trust": 0.6
},
{
"db": "IVD",
"id": "47CF2633-AF46-4636-89D7-2C1A2EDBC992",
"trust": 0.2
},
{
"db": "IVD",
"id": "74948927-D328-4F80-9F7C-7522889DB29E",
"trust": 0.2
},
{
"db": "IVD",
"id": "E2497741-9C48-468F-B5ED-39AD38F987AE",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-185604",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "VULHUB",
"id": "VHN-185604"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
},
{
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"id": "VAR-202003-1445",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "VULHUB",
"id": "VHN-185604"
}
],
"trust": 2.3
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 1.2
}
],
"sources": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
}
]
},
"last_update_date": "2024-11-23T22:44:38.143000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2020-070-01",
"trust": 0.8,
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/"
},
{
"title": "Schneider Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-084-02"
},
{
"title": "Patch for Schneider Electric Interactive Graphical SCADA System Access Control Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/211413"
},
{
"title": "Schneider Electric Interactive Graphical SCADA System Fixes for access control error vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=112782"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-185604"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.1,
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-084-02"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-7479"
},
{
"trust": 1.7,
"url": "https://www.se.com/ww/en/download/document/sevd-2020-070-01/"
},
{
"trust": 1.7,
"url": "https://www.zerodayinitiative.com/advisories/zdi-20-370/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7479"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/46227"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.1085/"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "VULHUB",
"id": "VHN-185604"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
},
{
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "VULHUB",
"id": "VHN-185604"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
},
{
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-03-23T00:00:00",
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"date": "2020-03-23T00:00:00",
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"date": "2020-03-23T00:00:00",
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"date": "2020-04-03T00:00:00",
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"date": "2020-03-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"date": "2020-03-23T00:00:00",
"db": "VULHUB",
"id": "VHN-185604"
},
{
"date": "2020-04-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"date": "2020-03-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202003-1340"
},
{
"date": "2020-03-23T20:15:12.450000",
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-03T00:00:00",
"db": "ZDI",
"id": "ZDI-20-370"
},
{
"date": "2020-03-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"date": "2022-10-06T00:00:00",
"db": "VULHUB",
"id": "VHN-185604"
},
{
"date": "2020-06-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003179"
},
{
"date": "2020-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202003-1340"
},
{
"date": "2024-11-21T05:37:13.673000",
"db": "NVD",
"id": "CVE-2020-7479"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Interactive Graphical SCADA System Access Control Error Vulnerability",
"sources": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "CNVD",
"id": "CNVD-2020-19888"
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
}
],
"trust": 1.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Access control error",
"sources": [
{
"db": "IVD",
"id": "47cf2633-af46-4636-89d7-2c1a2edbc992"
},
{
"db": "IVD",
"id": "74948927-d328-4f80-9f7c-7522889db29e"
},
{
"db": "IVD",
"id": "e2497741-9c48-468f-b5ed-39ad38f987ae"
},
{
"db": "CNNVD",
"id": "CNNVD-202003-1340"
}
],
"trust": 1.2
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.