VAR-201909-1000
Vulnerability from variot - Updated: 2025-10-03 22:173S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. 3S-Smart Software Solutions CODESYS Control is a set of industrial control program programming software from Germany 3S-Smart Software Solutions. A code issue vulnerability exists in 3S-Smart Software Solutions CODESYS Control. The vulnerability originates from improper design or implementation during code development of a network system or product. The following products and versions are affected: CODESYS Control for BeagleBone 3.5.11.0 to 3.5.15.0, CODESYS Control for emPC-A / iMX6 3.5.11.0 to 3.5.15.0, and CODESYS Control for IOT2000 3.5.11.0 to 3.5. Version 15.0, CODESYS Control for Linux 3.5.11.0 to 3.5.15.0, CODESYS Control for PFC100 3.5.11.0 to 3.5.15.0, CODESYS Control for PFC200 3.5.11.0 to 3.5.15.0, CODESYS Control for Raspberry Pi Version 3.5.11.0 to 3.5.15.0, CODESYS Control RTE V3 3.5.11.0 to 3.5.15.0, CODESYS Control RTE V3 3.5.11.0 to 3.5.15.0 (for Beckhoff CX), CODESYS Control Win V3 3.5.11.0 Version to 3.5.15.0 (also part of CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit version 3.5.11.0 to 3.5.15.0
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201909-1000",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "software solutions codesys control rte",
"scope": "eq",
"trust": 1.2,
"vendor": "3s smart",
"version": "v3\u003e=3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "control for pfc100",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control for empc-a\\/imx6",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control for pfc100",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control win",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control win",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control for iot2000",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control for iot2000",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control for empc-a\\/imx6",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control for beaglebone",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "linux",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control for pfc200",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control rte",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control rte",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "runtime system toolkit",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control for beaglebone",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "linux",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control for pfc200",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "runtime system toolkit",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control for raspberry pi",
"scope": "gte",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.11.0"
},
{
"model": "control for raspberry pi",
"scope": "lt",
"trust": 1.0,
"vendor": "codesys",
"version": "3.5.15.0"
},
{
"model": "control runtime system toolkit",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control for raspberry pi sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control for iot2000 sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control for empc-a/imx6 sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control for beaglebone sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control rte sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control for linux sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control win sl",
"scope": "eq",
"trust": 0.8,
"vendor": "codesys",
"version": "3.5.11.0 to 3.5.15.0"
},
{
"model": "control for pfc200 sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "control for pfc100 sl",
"scope": null,
"trust": 0.8,
"vendor": "codesys",
"version": null
},
{
"model": "software solutions codesys control for beaglebone",
"scope": "gte",
"trust": 0.6,
"vendor": "3s smart",
"version": "3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control for empc-a/imx",
"scope": "gte",
"trust": 0.6,
"vendor": "3s smart",
"version": "63.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control for iot2000",
"scope": "gte",
"trust": 0.6,
"vendor": "3s smart",
"version": "3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control for linux",
"scope": "gte",
"trust": 0.6,
"vendor": "3s smart",
"version": "3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control for pfc100",
"scope": "gte",
"trust": 0.6,
"vendor": "3s smart",
"version": "3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control for pfc200",
"scope": "gte",
"trust": 0.6,
"vendor": "3s smart",
"version": "3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control for raspberry pi",
"scope": "gte",
"trust": 0.6,
"vendor": "3s smart",
"version": "3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control win",
"scope": "eq",
"trust": 0.6,
"vendor": "3s smart",
"version": "v3\u003e=3.5.11.0,\u003c=3.5.15.0"
},
{
"model": "software solutions codesys control runtime system toolkit",
"scope": "eq",
"trust": 0.6,
"vendor": "3s smart",
"version": "v3\u003e=3.5.11.0,\u003c=3.5.15.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control for beaglebone",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control for empc a imx6",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control for iot2000",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control for pfc100",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control for pfc200",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control for raspberry pi",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control rte",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "control win",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "linux",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "runtime system toolkit",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"cve": "CVE-2019-13542",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CVE-2019-13542",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-32460",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "0388bd06-7396-4425-9011-862e9649841c",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2019-13542",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-13542",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-13542",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2019-13542",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2019-32460",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201909-656",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c",
"trust": 0.2,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. 3S-Smart Software Solutions CODESYS Control is a set of industrial control program programming software from Germany 3S-Smart Software Solutions. \nA code issue vulnerability exists in 3S-Smart Software Solutions CODESYS Control. The vulnerability originates from improper design or implementation during code development of a network system or product. The following products and versions are affected: CODESYS Control for BeagleBone 3.5.11.0 to 3.5.15.0, CODESYS Control for emPC-A / iMX6 3.5.11.0 to 3.5.15.0, and CODESYS Control for IOT2000 3.5.11.0 to 3.5. Version 15.0, CODESYS Control for Linux 3.5.11.0 to 3.5.15.0, CODESYS Control for PFC100 3.5.11.0 to 3.5.15.0, CODESYS Control for PFC200 3.5.11.0 to 3.5.15.0, CODESYS Control for Raspberry Pi Version 3.5.11.0 to 3.5.15.0, CODESYS Control RTE V3 3.5.11.0 to 3.5.15.0, CODESYS Control RTE V3 3.5.11.0 to 3.5.15.0 (for Beckhoff CX), CODESYS Control Win V3 3.5.11.0 Version to 3.5.15.0 (also part of CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit version 3.5.11.0 to 3.5.15.0",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-13542"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-13542",
"trust": 4.0
},
{
"db": "ICS CERT",
"id": "ICSA-19-255-04",
"trust": 3.0
},
{
"db": "AUSCERT",
"id": "ESB-2019.3487",
"trust": 1.2
},
{
"db": "CNVD",
"id": "CNVD-2019-32460",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-25-273-04",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90492166",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-19-255-03",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-19-255-05",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-19-255-02",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-19-255-01",
"trust": 0.6
},
{
"db": "IVD",
"id": "0388BD06-7396-4425-9011-862E9649841C",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"id": "VAR-201909-1000",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
}
],
"trust": 1.8
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
}
]
},
"last_update_date": "2025-10-03T22:17:04.526000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.codesys.com/"
},
{
"title": "3S-Smart Software Solutions CODESYS Control Code Issue Vulnerability Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/181473"
},
{
"title": "CODESYS Control V3 runtime systems Fixes for code issue vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=98230"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-476",
"trust": 1.0
},
{
"problemtype": "NULL Pointer dereference (CWE-476) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-13542"
},
{
"trust": 1.2,
"url": "https://www.auscert.org.au/bulletins/esb-2019.3487/"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90492166/index.html"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-273-04"
},
{
"trust": 0.6,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-05"
},
{
"trust": 0.6,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-03"
},
{
"trust": 0.6,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-02"
},
{
"trust": 0.6,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-01"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-09-21T00:00:00",
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"date": "2019-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"date": "2019-09-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"date": "2019-09-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"date": "2019-09-17T19:15:10.757000",
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-32460"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201909-656"
},
{
"date": "2025-10-02T07:54:00",
"db": "JVNDB",
"id": "JVNDB-2019-009520"
},
{
"date": "2024-11-21T04:25:06.737000",
"db": "NVD",
"id": "CVE-2019-13542"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "3S-Smart Software Solutions CODESYS Control Code Issue Vulnerability",
"sources": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNVD",
"id": "CNVD-2019-32460"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Code problem",
"sources": [
{
"db": "IVD",
"id": "0388bd06-7396-4425-9011-862e9649841c"
},
{
"db": "CNNVD",
"id": "CNNVD-201909-656"
}
],
"trust": 0.8
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.