VAR-201908-1826

Vulnerability from variot - Updated: 2024-11-23 22:51

A vulnerability of remote credential disclosure was discovered in Advan VD-1 firmware versions up to 230. An attacker can export system configuration which is not encrypted to get the administrator’s account and password in plain text via cgibin/ExportSettings.cgi?Export=1 without any authentication. AndroVideo Advan VD-1 is a security camera from Taiwan's AndroVideo.

AndroVideo Advan VD-1 has a trust management issue vulnerability. AndroVideo Advan VD-1 is a security camera produced by AndroVideo Company in Taiwan, China. to attack affected components

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201908-1826",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "gv-vr360",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "geovision",
        "version": "1.10"
      },
      {
        "model": "vd 1",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "androvideo",
        "version": "230"
      },
      {
        "model": "gv-vd8700",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "geovision",
        "version": "1.01"
      },
      {
        "model": "advan vd-1",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "androvideo",
        "version": "230"
      },
      {
        "model": "gv-vd8700",
        "scope": null,
        "trust": 0.8,
        "vendor": "geovision",
        "version": null
      },
      {
        "model": "gv-vr360",
        "scope": null,
        "trust": 0.8,
        "vendor": "geovision",
        "version": null
      },
      {
        "model": "advan vd-1",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "androvideo",
        "version": "\u003c=230"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:androvideo:vd_1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:geovision:gv-vd8700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:geovision:gv-vr360_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      }
    ]
  },
  "cve": "CVE-2019-11064",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-11064",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-34625",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-142673",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-11064",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-11064",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-11064",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-11064",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-34625",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201908-2174",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-142673",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-11064",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-11064"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability of remote credential disclosure was discovered in Advan VD-1 firmware versions up to 230. An attacker can export system configuration which is not encrypted to get the administrator\u2019s account and password in plain text via cgibin/ExportSettings.cgi?Export=1 without any authentication. AndroVideo Advan VD-1 is a security camera from Taiwan\u0027s AndroVideo. \n\nAndroVideo Advan VD-1 has a trust management issue vulnerability. AndroVideo Advan VD-1 is a security camera produced by AndroVideo Company in Taiwan, China. to attack affected components",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-11064"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-11064"
      }
    ],
    "trust": 2.34
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-11064",
        "trust": 3.2
      },
      {
        "db": "TWCERT",
        "id": "TVN-201906005",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-142673",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-11064",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-11064"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "id": "VAR-201908-1826",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142673"
      }
    ],
    "trust": 1.4222222
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "IoT"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:51:40.486000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.androvideo.com/"
      },
      {
        "title": "GV-VR360",
        "trust": 0.8,
        "url": "http://www.geovision.com.tw/jp/product/GV-VR360"
      },
      {
        "title": "GV-VD8700",
        "trust": 0.8,
        "url": "http://www.geovision.com.tw/jp/product/GV-VD8700"
      },
      {
        "title": "Patch for AndroVideo Advan VD-1 Trust Management Issue Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/183549"
      },
      {
        "title": "AndroVideo Advan VD-1 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=97657"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-200",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-255",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://gist.github.com/keniver/f5155b42eb278ec0273b83565b64235b#file-androvideo-advan-vd-1-multiple-vulnerabilities-md"
      },
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-11064"
      },
      {
        "trust": 1.8,
        "url": "http://surl.twcert.org.tw/gcdqn"
      },
      {
        "trust": 1.8,
        "url": "https://tvn.twcert.org.tw/taiwanvn/tvn-201906005"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-11064"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/287.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-11064"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-11064"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-10-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "date": "2019-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "date": "2019-08-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-11064"
      },
      {
        "date": "2019-09-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "date": "2019-08-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      },
      {
        "date": "2019-08-29T01:15:11.087000",
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-10-11T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-34625"
      },
      {
        "date": "2020-10-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-142673"
      },
      {
        "date": "2020-10-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-11064"
      },
      {
        "date": "2019-09-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      },
      {
        "date": "2020-10-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      },
      {
        "date": "2024-11-21T04:20:28.083000",
        "db": "NVD",
        "id": "CVE-2019-11064"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Advan VD-1 Firmware vulnerabilities related to certificate and password management",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-008724"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201908-2174"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.