VAR-201908-1825
Vulnerability from variot - Updated: 2025-01-30 21:21A broken access control vulnerability in SmartHome app (Android versions up to 3.0.42_190515, ios versions up to 2.0.22) allows an attacker in the same local area network to list user accounts and control IoT devices that connect with its gateway (HG100) via http://[target]/smarthome/devicecontrol without any authentication. CVSS 3.0 base score 10 (Confidentiality, Integrity and Availability impacts). CVSS vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). SmartHome The application contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ASUS SmartHome is a smart home control management application from ASUS in Taiwan
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201908-1825",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smarthome",
"scope": "lt",
"trust": 1.0,
"vendor": "asus",
"version": "2.0.22"
},
{
"model": "smarthome",
"scope": "lt",
"trust": 1.0,
"vendor": "asus",
"version": "3.0.42_190515"
},
{
"model": "smarthome",
"scope": "eq",
"trust": 0.8,
"vendor": "asustek computer",
"version": "(android)"
},
{
"model": "smarthome",
"scope": "eq",
"trust": 0.8,
"vendor": "asustek computer",
"version": "(ios)"
},
{
"model": "smarthome for ios",
"scope": "lte",
"trust": 0.6,
"vendor": "asus",
"version": "\u003c=2.0.22"
},
{
"model": "smarthome for android \u003c=3.0.42 190515",
"scope": null,
"trust": 0.6,
"vendor": "asus",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:asus:smarthome",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
}
]
},
"cve": "CVE-2019-11063",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CVE-2019-11063",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2020-22303",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "VHN-142672",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:A/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2019-11063",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "twcert@cert.org.tw",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2019-11063",
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-11063",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "twcert@cert.org.tw",
"id": "CVE-2019-11063",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2019-11063",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2020-22303",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201908-2173",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-142672",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "VULHUB",
"id": "VHN-142672"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
},
{
"db": "NVD",
"id": "CVE-2019-11063"
},
{
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A broken access control vulnerability in SmartHome app (Android versions up to 3.0.42_190515, ios versions up to 2.0.22) allows an attacker in the same local area network to list user accounts and control IoT devices that connect with its gateway (HG100) via http://[target]/smarthome/devicecontrol without any authentication. CVSS 3.0 base score 10 (Confidentiality, Integrity and Availability impacts). CVSS vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). SmartHome The application contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ASUS SmartHome is a smart home control management application from ASUS in Taiwan",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-11063"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
},
{
"db": "VULHUB",
"id": "VHN-142672"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-11063",
"trust": 3.2
},
{
"db": "TWCERT",
"id": "TVN-201908014",
"trust": 2.3
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-22303",
"trust": 0.7
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173",
"trust": 0.7
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-142672",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "VULHUB",
"id": "VHN-142672"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
},
{
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"id": "VAR-201908-1825",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "VULHUB",
"id": "VHN-142672"
}
],
"trust": 1.8
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"home \u0026 office device",
"network device"
],
"sub_category": "smart home device",
"trust": 0.1
},
{
"category": [
"home \u0026 office device",
"network device"
],
"sub_category": "gateway",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CNVD",
"id": "CNVD-2020-22303"
}
]
},
"last_update_date": "2025-01-30T21:21:44.381000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ASUS SmartHome",
"trust": 0.8,
"url": "https://play.google.com/store/apps/details?id=com.asus.zhenaudi\u0026hl=en_US"
},
{
"title": "Patch for ASUS SmartHome Access Control Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/213459"
},
{
"title": "ASUS SmartHome Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=97656"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.1
},
{
"problemtype": "CWE-284",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-142672"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://tvn.twcert.org.tw/taiwanvn/tvn-201908014"
},
{
"trust": 1.7,
"url": "http://surl.twcert.org.tw/5lwqj"
},
{
"trust": 1.7,
"url": "https://github.com/tim124058/asus-smarthome-exploit/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-11063"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-11063"
},
{
"trust": 0.8,
"url": "https://twcert.org.tw/subpages/servethepublic/public_document_details.aspx?lang=en-us\u0026id=43"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "VULHUB",
"id": "VHN-142672"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
},
{
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "VULHUB",
"id": "VHN-142672"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
},
{
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"date": "2019-08-29T00:00:00",
"db": "VULHUB",
"id": "VHN-142672"
},
{
"date": "2019-09-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"date": "2019-08-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201908-2173"
},
{
"date": "2019-08-29T01:15:10.990000",
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-142672"
},
{
"date": "2019-09-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-008840"
},
{
"date": "2020-09-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201908-2173"
},
{
"date": "2024-11-21T04:20:27.973000",
"db": "NVD",
"id": "CVE-2019-11063"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "ASUS SmartHome Access Control Error Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-22303"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201908-2173"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.