VAR-201908-0067
Vulnerability from variot - Updated: 2024-11-23 22:16All versions up to V1.1.10P3T18 of ZTE ZXHN F670 product are impacted by command injection vulnerability. Due to insufficient parameter validation check, an authorized user can exploit this vulnerability to take control of user router system. ZTE ZXHN F670 Contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ZTE ZXHN F670 is a modem from China ZTE Corporation (ZTE). An attacker could exploit the vulnerability to execute an illegal command. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201908-0067",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "zxhn f670",
"scope": "lte",
"trust": 1.8,
"vendor": "zte",
"version": "1.1.10p3t18"
},
{
"model": "zxhn f670 \u003c=1.1.10p3t18",
"scope": null,
"trust": 0.6,
"vendor": "zte",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:zte:zxhn_f670_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Egor Dimitrenko and Alexandr Shvetsov at Positive Technologies",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
}
],
"trust": 0.6
},
"cve": "CVE-2019-3417",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2019-3417",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-41898",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-154852",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2019-3417",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "psirt@zte.com.cn",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.7,
"id": "CVE-2019-3417",
"impactScore": 5.8,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-3417",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-3417",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "psirt@zte.com.cn",
"id": "CVE-2019-3417",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2019-3417",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-41898",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201908-1108",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-154852",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "VULHUB",
"id": "VHN-154852"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
},
{
"db": "NVD",
"id": "CVE-2019-3417"
},
{
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "All versions up to V1.1.10P3T18 of ZTE ZXHN F670 product are impacted by command injection vulnerability. Due to insufficient parameter validation check, an authorized user can exploit this vulnerability to take control of user router system. ZTE ZXHN F670 Contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ZTE ZXHN F670 is a modem from China ZTE Corporation (ZTE). An attacker could exploit the vulnerability to execute an illegal command. This vulnerability stems from the fact that the network system or product does not correctly filter special elements in the process of constructing executable commands from external input data",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-3417"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "VULHUB",
"id": "VHN-154852"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-3417",
"trust": 3.1
},
{
"db": "ZTE",
"id": "1010163",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201908-1108",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-41898",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-154852",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "VULHUB",
"id": "VHN-154852"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
},
{
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"id": "VAR-201908-0067",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "VULHUB",
"id": "VHN-154852"
}
],
"trust": 1.35217394
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
}
]
},
"last_update_date": "2024-11-23T22:16:56.119000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Two Vulnerabilities in ZTE ZXHN F670 Product",
"trust": 0.8,
"url": "http://support.zte.com.cn/support/news/LoopholeInfoDetail.aspx?newsId=1010163"
},
{
"title": "Patch for ZTE ZXHN F670 Command Injection Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/191429"
},
{
"title": "ZTE ZXHN F670 Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=96773"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-154852"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-3417"
},
{
"trust": 1.7,
"url": "http://support.zte.com.cn/support/news/loopholeinfodetail.aspx?newsid=1010163"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3417"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "VULHUB",
"id": "VHN-154852"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
},
{
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "VULHUB",
"id": "VHN-154852"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
},
{
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-11-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"date": "2019-08-15T00:00:00",
"db": "VULHUB",
"id": "VHN-154852"
},
{
"date": "2019-08-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"date": "2019-08-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201908-1108"
},
{
"date": "2019-08-15T15:15:16.500000",
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-11-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"date": "2023-03-03T00:00:00",
"db": "VULHUB",
"id": "VHN-154852"
},
{
"date": "2019-08-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-008356"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201908-1108"
},
{
"date": "2024-11-21T04:42:03.537000",
"db": "NVD",
"id": "CVE-2019-3417"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "ZTE ZXHN F670 Command Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-41898"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-008356"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201908-1108"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.