Vulnerability from variot - Updated: 2024-11-23 21:37The Quest Kace K1000 Appliance, versions prior to 9.0.270, allows an authenticated, remote attacker with least privileges ('User Console Only' role) to potentially exploit multiple Blind SQL Injection vulnerabilities to retrieve sensitive information from the database or copy the entire database. An authenticated remote attacker could leverage Blind SQL injections to obtain sensitive data. The Quest Kace System Management (K1000) Appliance contains multiple vulnerabilities, including a blind SQL injection vulnerability and a stored cross site scripting vulnerability. It also suffers from misconfigurations in the cross-origin resource sharing (CORS) mechanism and improperly validates source communications. QuestSoftwareKaceK1000Appliance is a system management device from QuestSoftware, USA. This product is mainly used for software license management, patch and endpoint security management, software distribution and server monitoring
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201906-1118",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "kace systems management appliance",
"scope": "lt",
"trust": 1.8,
"vendor": "quest",
"version": "9.0.270"
},
{
"model": null,
"scope": null,
"trust": 0.8,
"vendor": "quest kace",
"version": null
},
{
"model": "software kace k1000 appliance",
"scope": "lt",
"trust": 0.6,
"vendor": "quest",
"version": "9.0.270"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#877837"
},
{
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:quest:kace_systems_management_appliance",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
}
]
},
"cve": "CVE-2018-5404",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2018-5404",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-21112",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2018-5404",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-5404",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2018-5404",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2019-21112",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201906-043",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
},
{
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Quest Kace K1000 Appliance, versions prior to 9.0.270, allows an authenticated, remote attacker with least privileges (\u0027User Console Only\u0027 role) to potentially exploit multiple Blind SQL Injection vulnerabilities to retrieve sensitive information from the database or copy the entire database. An authenticated remote attacker could leverage Blind SQL injections to obtain sensitive data. The Quest Kace System Management (K1000) Appliance contains multiple vulnerabilities, including a blind SQL injection vulnerability and a stored cross site scripting vulnerability. It also suffers from misconfigurations in the cross-origin resource sharing (CORS) mechanism and improperly validates source communications. QuestSoftwareKaceK1000Appliance is a system management device from QuestSoftware, USA. This product is mainly used for software license management, patch and endpoint security management, software distribution and server monitoring",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-5404"
},
{
"db": "CERT/CC",
"id": "VU#877837"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "CNVD",
"id": "CNVD-2019-21112"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-5404",
"trust": 3.8
},
{
"db": "CERT/CC",
"id": "VU#877837",
"trust": 3.8
},
{
"db": "JVN",
"id": "JVNVU91210160",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-21112",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201906-043",
"trust": 0.6
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#877837"
},
{
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
},
{
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"id": "VAR-201906-1118",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-21112"
}
],
"trust": 1.2666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-21112"
}
]
},
"last_update_date": "2024-11-23T21:37:12.158000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.quest.com/"
},
{
"title": "QuestSoftwareKaceK1000ApplianceSQL injection vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/166971"
},
{
"title": "Quest Software Kace K1000 Appliance SQL Repair measures for injecting vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93135"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-89",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://support.quest.com/kb/288310/cert-coordination-center-report-update"
},
{
"trust": 3.0,
"url": "https://www.kb.cert.org/vuls/id/877837/"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-5404"
},
{
"trust": 1.6,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5404"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5405"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5406"
},
{
"trust": 0.8,
"url": "https://support.quest.com/kace-systems-management-appliance/9.1/download-new-releaseshttps://support.quest.com/https://support.quest.com/kb/288310/cert-coordination-center-report-update"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91210160/index.html"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#877837"
},
{
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
},
{
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#877837"
},
{
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
},
{
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-06-01T00:00:00",
"db": "CERT/CC",
"id": "VU#877837"
},
{
"date": "2019-07-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"date": "2019-06-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"date": "2019-06-03T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-043"
},
{
"date": "2019-06-03T19:29:01.593000",
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-06-03T00:00:00",
"db": "CERT/CC",
"id": "VU#877837"
},
{
"date": "2019-07-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"date": "2019-06-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015568"
},
{
"date": "2019-06-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-043"
},
{
"date": "2024-11-21T04:08:45.120000",
"db": "NVD",
"id": "CVE-2018-5404"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Quest Software Kace K1000 Appliance SQL Injection Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-21112"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SQL injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-043"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.