VAR-201905-1113

Vulnerability from variot - Updated: 2024-11-23 22:44

iBall Baton iB-WRB302N20122017 devices have improper access control over the UART interface, allowing physical attackers to discover Wi-Fi credentials (plain text) and the web-console password (base64) via the debugging console. iBall Baton The device contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. iBallBatoniB-WRB302N is a wireless router from iBall India. A trust management issue vulnerability exists in the iBallBatoniB-WRB302N20122017 release. The vulnerability stems from the lack of an effective trust management mechanism in network systems or products. An attacker can attack an affected component with a default password or hard-coded password, hard-coded certificate, and so on. to attack affected components

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-1113",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ib-wrb302n",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "iball",
        "version": "ib-wrb302n20122017"
      },
      {
        "model": "300m 2 port wireless n broadband router",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "iball",
        "version": "ib-wrb302n20122017"
      },
      {
        "model": "baton ib-wrb302n ib-wrb302n20122017",
        "scope": null,
        "trust": 0.6,
        "vendor": "iball",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:iball:300m_2-port_wireless-n_broadband_router_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      }
    ]
  },
  "cve": "CVE-2018-20008",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-20008",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2019-16607",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "VHN-130771",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2018-20008",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Physical",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.8,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-20008",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-20008",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-20008",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-16607",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-1044",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-130771",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "db": "VULHUB",
        "id": "VHN-130771"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1044"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "iBall Baton iB-WRB302N20122017 devices have improper access control over the UART interface, allowing physical attackers to discover Wi-Fi credentials (plain text) and the web-console password (base64) via the debugging console. iBall Baton The device contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. iBallBatoniB-WRB302N is a wireless router from iBall India. A trust management issue vulnerability exists in the iBallBatoniB-WRB302N20122017 release. The vulnerability stems from the lack of an effective trust management mechanism in network systems or products. An attacker can attack an affected component with a default password or hard-coded password, hard-coded certificate, and so on. to attack affected components",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-20008"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "db": "VULHUB",
        "id": "VHN-130771"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-20008",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1044",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-130771",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "db": "VULHUB",
        "id": "VHN-130771"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1044"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "id": "VAR-201905-1113",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "db": "VULHUB",
        "id": "VHN-130771"
      }
    ],
    "trust": 1.7
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:44:59.063000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "300M 2-Port Wireless-N Broadband Router",
        "trust": 0.8,
        "url": "https://www.iball.co.in/Product/300M-2-Port-Wireless-N-Broadband-Router/11209"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-312",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-732",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-255",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-130771"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://payatu.com/ibaton-routers-responsible-disclosure/"
      },
      {
        "trust": 1.7,
        "url": "https://www.iball.co.in/category/baton/283"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-20008"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-20008"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "db": "VULHUB",
        "id": "VHN-130771"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1044"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "db": "VULHUB",
        "id": "VHN-130771"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1044"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-06-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "date": "2019-05-28T00:00:00",
        "db": "VULHUB",
        "id": "VHN-130771"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "date": "2019-05-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-1044"
      },
      {
        "date": "2019-05-28T21:29:00.327000",
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-06-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-16607"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-130771"
      },
      {
        "date": "2019-06-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-1044"
      },
      {
        "date": "2024-11-21T04:00:44.493000",
        "db": "NVD",
        "id": "CVE-2018-20008"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "iBall Baton Vulnerabilities related to certificate and password management in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-015522"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1044"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…