VAR-201905-0656
Vulnerability from variot - Updated: 2024-11-23 23:01The Billion 5200W-T TCLinux Fw $7.3.8.0 v008 130603 router distributed by TrueOnline has three user accounts with default passwords, including two hardcoded service accounts: one with the username true and password true, and another with the username user3 and and a long password consisting of a repetition of the string 0123456789. These accounts can be used to login to the web interface, exploit authenticated command injections, and change router settings for malicious purposes. Billion 5200W-T Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Billion Electric 5200W-T is a wireless router produced by British company Billion Electric. A trust management issue vulnerability exists in the Billion 5200W-T using firmware version 7.3.8.0. This vulnerability stems from the lack of an effective trust management mechanism in network systems or products. Attackers can use default passwords or hard-coded passwords, hard-coded certificates, etc. to attack affected components
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201905-0656",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "5200w-t",
"scope": "eq",
"trust": 1.0,
"vendor": "billion",
"version": "7.3.8.0"
},
{
"model": "5200w-t",
"scope": null,
"trust": 0.8,
"vendor": "billion",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:billion:5200w-t_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
}
]
},
"cve": "CVE-2017-18373",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2017-18373",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "VHN-109489",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2017-18373",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-18373",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-18373",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201905-078",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-109489",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-109489"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-078"
},
{
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Billion 5200W-T TCLinux Fw $7.3.8.0 v008 130603 router distributed by TrueOnline has three user accounts with default passwords, including two hardcoded service accounts: one with the username true and password true, and another with the username user3 and and a long password consisting of a repetition of the string 0123456789. These accounts can be used to login to the web interface, exploit authenticated command injections, and change router settings for malicious purposes. Billion 5200W-T Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Billion Electric 5200W-T is a wireless router produced by British company Billion Electric. A trust management issue vulnerability exists in the Billion 5200W-T using firmware version 7.3.8.0. This vulnerability stems from the lack of an effective trust management mechanism in network systems or products. Attackers can use default passwords or hard-coded passwords, hard-coded certificates, etc. to attack affected components",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-18373"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"db": "VULHUB",
"id": "VHN-109489"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-18373",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014434",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201905-078",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-109489",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-109489"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-078"
},
{
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"id": "VAR-201905-0656",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-109489"
}
],
"trust": 0.01
},
"last_update_date": "2024-11-23T23:01:50.385000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.billion.com.tw/index.aspx"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-109489"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://seclists.org/fulldisclosure/2017/jan/40"
},
{
"trust": 1.7,
"url": "https://raw.githubusercontent.com/pedrib/poc/master/advisories/zyxel_trueonline.txt"
},
{
"trust": 1.7,
"url": "https://ssd-disclosure.com/index.php/archives/2910"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-18373"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-18373"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-109489"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-078"
},
{
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-109489"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-078"
},
{
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-02T00:00:00",
"db": "VULHUB",
"id": "VHN-109489"
},
{
"date": "2019-05-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"date": "2019-05-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-078"
},
{
"date": "2019-05-02T17:29:01.363000",
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-03T00:00:00",
"db": "VULHUB",
"id": "VHN-109489"
},
{
"date": "2019-05-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-014434"
},
{
"date": "2019-05-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-078"
},
{
"date": "2024-11-21T03:19:57.680000",
"db": "NVD",
"id": "CVE-2017-18373"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-078"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Billion 5200W-T Vulnerabilities related to the use of hard-coded credentials",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-014434"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-078"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.