VAR-201905-0600
Vulnerability from variot - Updated: 2024-11-23 22:33A vulnerability in the Secure Shell (SSH) authentication process of Cisco Small Business Switches software could allow an attacker to bypass client-side certificate authentication and revert to password authentication. The vulnerability exists because OpenSSH mishandles the authentication process. An attacker could exploit this vulnerability by attempting to connect to the device via SSH. A successful exploit could allow the attacker to access the configuration as an administrative user if the default credentials are not changed. There are no workarounds available; however, if client-side certificate authentication is enabled, disable it and use strong password authentication. Client-side certificate authentication is disabled by default. Cisco Small Business Switches There is an authorization vulnerability in the software.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. An attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may lead to further attacks. This issue is being tracked by Cisco bugs CSCvo28588, CSCvp35704
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201905-0600",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sx550x-12f",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg550x-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350-10mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf300-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-50fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-26fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350xg-24t",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-28mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-52mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-24mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350xg-24f",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf200-24fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-18",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-28p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sx550x-52",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-10pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-10sfp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350-28p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf500-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf550x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf350-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf500-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf200-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-52p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-26",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf550x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf200-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf300-48pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-28mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350xg-2f10",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-28",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-52",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-26",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-50p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf250-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-10",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-18",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-50hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350xg-48t",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-10fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500xg-8f8t",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf250-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-24ft",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg550x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-08p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-20",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500-52",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf500-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf250-48hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg355-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg550x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-26p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-50p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-10mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf250-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf500-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-26hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-50",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-10mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf350-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-24f",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500-52p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf200-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-28pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-28",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-28p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350-28",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-16ft",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-26p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-08hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf200-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-52mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf350-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350-28mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-50",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350-10",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf302-08p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "200 series smart switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "250 series smart switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "350 series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "350x series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "500 series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "small business 300 series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "small business series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "5002.4.0.92"
},
{
"model": "small business series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "5001.4.2.04"
},
{
"model": "small business series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "3001.4.2.04"
},
{
"model": "small business series smart switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "2001.4.2.04"
},
{
"model": "series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.4.5.71"
},
{
"model": "series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.3.0.130"
},
{
"model": "series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.2.5.68"
},
{
"model": "series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "350x2.4.5.71"
},
{
"model": "series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "3502.4.5.71"
},
{
"model": "series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "3502.3.0.130"
},
{
"model": "series smart switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "2502.4.5.71"
},
{
"model": "small business series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "5001.4.10.6"
},
{
"model": "small business series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "3001.4.10.6"
},
{
"model": "small business series smart switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "2001.4.10.6"
},
{
"model": "series stackable managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.5.0.78"
},
{
"model": "series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "350x2.5.0.78"
},
{
"model": "series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "3502.5.0.78"
},
{
"model": "series smart switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "2502.5.0.78"
}
],
"sources": [
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:cisco:200_series_smart_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:250_series_smart_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:small_business_350_series_managed_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:350x_series_managed_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:500_series_managed_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:small_business_300_series_managed_switches_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Katie Sexton and Jimi Sebree of Tenable Research.,Katie Sexton and Jimi Sebree of Tenable Research for reporting these vulnerabilities.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
],
"trust": 0.6
},
"cve": "CVE-2019-1859",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2019-1859",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ykramarz@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2019-1859",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2019-1859",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-1859",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "ykramarz@cisco.com",
"id": "CVE-2019-1859",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2019-1859",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201905-054",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2019-1859",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability in the Secure Shell (SSH) authentication process of Cisco Small Business Switches software could allow an attacker to bypass client-side certificate authentication and revert to password authentication. The vulnerability exists because OpenSSH mishandles the authentication process. An attacker could exploit this vulnerability by attempting to connect to the device via SSH. A successful exploit could allow the attacker to access the configuration as an administrative user if the default credentials are not changed. There are no workarounds available; however, if client-side certificate authentication is enabled, disable it and use strong password authentication. Client-side certificate authentication is disabled by default. Cisco Small Business Switches There is an authorization vulnerability in the software.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. \nAn attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may lead to further attacks. \nThis issue is being tracked by Cisco bugs CSCvo28588, CSCvp35704",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-1859"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "VULMON",
"id": "CVE-2019-1859"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-1859",
"trust": 2.8
},
{
"db": "BID",
"id": "108140",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2019.1536",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2019-1859",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"id": "VAR-201905-0600",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.4270171866666667
},
"last_update_date": "2024-11-23T22:33:55.680000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "cisco-sa-20190501-scbv",
"trust": 0.8,
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-scbv"
},
{
"title": "Multiple Cisco Product Authorization Issue Vulnerability Fixing Measures",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92197"
},
{
"title": "Cisco: Cisco Small Business Switches Secure Shell Certificate Authentication Bypass Vulnerability",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=cisco_security_advisories_and_alerts_ciscoproducts\u0026qid=cisco-sa-20190501-scbv"
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/cisco-critical-nexus-9000-flaw/144290/"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-285",
"trust": 1.8
},
{
"problemtype": "CWE-295",
"trust": 1.0
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.1,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190501-scbv"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-1859"
},
{
"trust": 0.9,
"url": "http://www.cisco.com/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-1859"
},
{
"trust": 0.7,
"url": "https://www.securityfocus.com/bid/108140"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/80182"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/295.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://threatpost.com/cisco-critical-nexus-9000-flaw/144290/"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-03T00:00:00",
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"date": "2019-05-01T00:00:00",
"db": "BID",
"id": "108140"
},
{
"date": "2019-06-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"date": "2019-05-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"date": "2019-05-03T17:29:01.500000",
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-10-13T00:00:00",
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"date": "2019-05-01T00:00:00",
"db": "BID",
"id": "108140"
},
{
"date": "2019-06-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"date": "2024-11-21T04:37:32.957000",
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco Small Business Switches Authorization vulnerabilities in software",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.