VAR-201905-0600
Vulnerability from variot - Updated: 2024-11-23 22:33A vulnerability in the Secure Shell (SSH) authentication process of Cisco Small Business Switches software could allow an attacker to bypass client-side certificate authentication and revert to password authentication. The vulnerability exists because OpenSSH mishandles the authentication process. An attacker could exploit this vulnerability by attempting to connect to the device via SSH. A successful exploit could allow the attacker to access the configuration as an administrative user if the default credentials are not changed. There are no workarounds available; however, if client-side certificate authentication is enabled, disable it and use strong password authentication. Client-side certificate authentication is disabled by default. Cisco Small Business Switches There is an authorization vulnerability in the software.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. An attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may lead to further attacks. This issue is being tracked by Cisco bugs CSCvo28588, CSCvp35704
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201905-0600",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sx550x-12f",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg550x-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350-10mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf300-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-50fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-26fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350xg-24t",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-28mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-52mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-24mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350xg-24f",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf200-24fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-18",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-28p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sx550x-52",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-10pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-10sfp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350-28p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf500-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf550x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf350-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf500-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf200-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-52p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-26",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf550x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf200-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf300-48pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-28mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350xg-2f10",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-28",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-52",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-26",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-50p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf250-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg300-10",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-18",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-50hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350xg-48t",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-10fp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500xg-8f8t",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf250-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-24ft",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg550x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-08p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-20",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg550x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500-52",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf500-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf250-48hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg355-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-24mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg550x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-26p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg200-50p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-10mpp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf250-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf302-08mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf500-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg250-26hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-48p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-50",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-10mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf350-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-24f",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500-52p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf200-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-28pp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf300-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-28",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg500-28p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350-28",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sx550x-16ft",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-26p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf550x-24p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg250-08hp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sf200-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-52mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf350-48mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg350-28mp",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-50",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350x-24",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg200-08",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg350-10",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "2.5.0.78"
},
{
"model": "sg500x-48",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sg300-10p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "sf302-08p",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.4.10.6"
},
{
"model": "200 series smart switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "250 series smart switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "350 series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "350x series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "500 series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "small business 300 series managed switch",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "small business series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "5002.4.0.92"
},
{
"model": "small business series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "5001.4.2.04"
},
{
"model": "small business series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "3001.4.2.04"
},
{
"model": "small business series smart switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "2001.4.2.04"
},
{
"model": "series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.4.5.71"
},
{
"model": "series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.3.0.130"
},
{
"model": "series stackable managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.2.5.68"
},
{
"model": "series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "350x2.4.5.71"
},
{
"model": "series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "3502.4.5.71"
},
{
"model": "series managed switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "3502.3.0.130"
},
{
"model": "series smart switches",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "2502.4.5.71"
},
{
"model": "small business series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "5001.4.10.6"
},
{
"model": "small business series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "3001.4.10.6"
},
{
"model": "small business series smart switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "2001.4.10.6"
},
{
"model": "series stackable managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "550x2.5.0.78"
},
{
"model": "series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "350x2.5.0.78"
},
{
"model": "series managed switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "3502.5.0.78"
},
{
"model": "series smart switches",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "2502.5.0.78"
}
],
"sources": [
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:cisco:200_series_smart_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:250_series_smart_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:small_business_350_series_managed_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:350x_series_managed_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:500_series_managed_switches_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:cisco:small_business_300_series_managed_switches_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Katie Sexton and Jimi Sebree of Tenable Research.,Katie Sexton and Jimi Sebree of Tenable Research for reporting these vulnerabilities.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
],
"trust": 0.6
},
"cve": "CVE-2019-1859",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2019-1859",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ykramarz@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2019-1859",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2019-1859",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-1859",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "ykramarz@cisco.com",
"id": "CVE-2019-1859",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2019-1859",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201905-054",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2019-1859",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability in the Secure Shell (SSH) authentication process of Cisco Small Business Switches software could allow an attacker to bypass client-side certificate authentication and revert to password authentication. The vulnerability exists because OpenSSH mishandles the authentication process. An attacker could exploit this vulnerability by attempting to connect to the device via SSH. A successful exploit could allow the attacker to access the configuration as an administrative user if the default credentials are not changed. There are no workarounds available; however, if client-side certificate authentication is enabled, disable it and use strong password authentication. Client-side certificate authentication is disabled by default. Cisco Small Business Switches There is an authorization vulnerability in the software.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. \nAn attacker can exploit this issue to bypass the authentication mechanism and gain unauthorized access. This may lead to further attacks. \nThis issue is being tracked by Cisco bugs CSCvo28588, CSCvp35704",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-1859"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "VULMON",
"id": "CVE-2019-1859"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-1859",
"trust": 2.8
},
{
"db": "BID",
"id": "108140",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2019.1536",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2019-1859",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"id": "VAR-201905-0600",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.4270171866666667
},
"last_update_date": "2024-11-23T22:33:55.680000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "cisco-sa-20190501-scbv",
"trust": 0.8,
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-scbv"
},
{
"title": "Multiple Cisco Product Authorization Issue Vulnerability Fixing Measures",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92197"
},
{
"title": "Cisco: Cisco Small Business Switches Secure Shell Certificate Authentication Bypass Vulnerability",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=cisco_security_advisories_and_alerts_ciscoproducts\u0026qid=cisco-sa-20190501-scbv"
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/cisco-critical-nexus-9000-flaw/144290/"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-285",
"trust": 1.8
},
{
"problemtype": "CWE-295",
"trust": 1.0
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.1,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20190501-scbv"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-1859"
},
{
"trust": 0.9,
"url": "http://www.cisco.com/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-1859"
},
{
"trust": 0.7,
"url": "https://www.securityfocus.com/bid/108140"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/80182"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/295.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://threatpost.com/cisco-critical-nexus-9000-flaw/144290/"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"db": "BID",
"id": "108140"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-03T00:00:00",
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"date": "2019-05-01T00:00:00",
"db": "BID",
"id": "108140"
},
{
"date": "2019-06-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"date": "2019-05-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"date": "2019-05-03T17:29:01.500000",
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-10-13T00:00:00",
"db": "VULMON",
"id": "CVE-2019-1859"
},
{
"date": "2019-05-01T00:00:00",
"db": "BID",
"id": "108140"
},
{
"date": "2019-06-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004454"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-054"
},
{
"date": "2024-11-21T04:37:32.957000",
"db": "NVD",
"id": "CVE-2019-1859"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco Small Business Switches Authorization vulnerabilities in software",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004454"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-054"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.