VAR-201905-0115

Vulnerability from variot - Updated: 2024-11-23 21:37

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities: 1. An information-disclosure vulnerability 2. A cross-site-scripting vulnerability 3. A security vulnerability An attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of correct validation of client data in WEB applications

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0115",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi op",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi tp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.1"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi classic devices",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime professional update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic wincc runtime advanced update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic wincc update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic hmi ktp mobile update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort outdoor panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported these vulnerabilities to NCCIC.,Siemens ProductCERT",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6577",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.8,
            "id": "CVE-2019-6577",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.8,
            "id": "VHN-158012",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.3,
            "id": "CVE-2019-6577",
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6577",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6577",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-588",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158012",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities:\n1. An information-disclosure vulnerability\n2. A cross-site-scripting vulnerability\n3. A security vulnerability\nAn attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of correct validation of client data in WEB applications",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6577",
        "trust": 2.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-09",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "108412",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-804486",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588",
        "trust": 0.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-02",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1716.2",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-54365",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-158012",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "id": "VAR-201905-0115",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      }
    ],
    "trust": 0.7545892989999999
  },
  "last_update_date": "2024-11-23T21:37:16.753000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-804486",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "title": "Siemens SIMATIC Panels  and WinCC Fixes for cross-site scripting vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92738"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-80",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/108412"
      },
      {
        "trust": 1.9,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-09"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6577"
      },
      {
        "trust": 0.9,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-09"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6577"
      },
      {
        "trust": 0.6,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-wincc-multiple-vulnerabilities-29288"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/80946"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "date": "2019-05-14T20:29:04.623000",
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "date": "2019-05-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "date": "2024-11-21T04:46:44.267000",
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  SIMATIC Product cross-site scripting vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour