VAR-201904-0089
Vulnerability from variot - Updated: 2024-11-23 21:24In various firmware versions of Lenovo System x, the integrated management module II (IMM2)'s first failure data capture (FFDC) includes the web server's private key in the generated log file for support. plural Lenovo System x The product contains a vulnerability related to information disclosure from log files.Information may be obtained. LenovoFlexSystemx240M4 and so on are all servers of China Lenovo. A security vulnerability exists in several Lenovo products that originated from the FFDC recording the private key of the web server in a log file. An attacker could exploit the vulnerability to disclose information. There are security vulnerabilities in several Lenovo products. The following products are affected: Lenovo Flex System x240 M4; Flex System x240 M5; Flex System x280 X6; Flex System x440 M4; Flex System x480 X6; Flex System x880; NeXtScale nx360 M5; (ThinkAgile CX2200/4200/4600); System x3650 M5; System x3750 M4; System x3850 X6; System x3950 X6; BladeCenter HS22; BladeCenter HS23; BladeCenter HS23E; Flex System x220 M4; System x280 M4; Flex System x440 M4; Flex System x480 M4; Flex System x880 M4; iDataPlex dx360 M4; iDataPlex dx360 M4 Water Cooled; x3300 M4; System x3500 M4; System x3530 M4; System x3550 M4; System x3630 M4; System x3650 M4;
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201904-0089",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "nextscale nx360 m5",
"scope": null,
"trust": 1.4,
"vendor": "lenovo",
"version": null
},
{
"model": "system x3250 m6",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "system x3500 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3650 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x240 m5",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "bladecenter hs22",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x222 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3300 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3250 m5",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x220 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "idataplex dx360 m4 water cooled",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3550 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3650 m4 bd",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3950 x6",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "nextscale nx360 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3530 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "bladecenter hs23",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3650 m4 hd",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3500 m5",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "system x3950 x6",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "flex system x240 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3650 m5",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "flex system x880 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3630 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3550 m5",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "flex system x240 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "flex system x440 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x480 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3250 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "nextscale nx360 m5",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "system x3750 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x280 x6",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "idataplex dx360 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x480 x6",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "system x3850 x6",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "system x3100 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x440 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "flex system x280 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3100 m5",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "system x3750 m4",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "bladecenter hs23e",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x880",
"scope": "lt",
"trust": 1.0,
"vendor": "lenovo",
"version": "5.30"
},
{
"model": "system x3850 x6",
"scope": "lt",
"trust": 1.0,
"vendor": "ibm",
"version": "7.20"
},
{
"model": "flex system x240 m4",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "flex system x240 m5",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "flex system x280 x6",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "flex system x440 m4",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "flex system x480 x6",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "flex system x880",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "system x3250 m6",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "system x3500 m5",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "system x3550 m5",
"scope": null,
"trust": 0.8,
"vendor": "lenovo",
"version": null
},
{
"model": "flex system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x240"
},
{
"model": "flex system m5",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x240"
},
{
"model": "flex system",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x280x6"
},
{
"model": "flex system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x440"
},
{
"model": "flex system",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x480x6"
},
{
"model": "flex system",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x880"
},
{
"model": "system m6",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3250"
},
{
"model": "system m5",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3500"
},
{
"model": "system m5",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3550"
},
{
"model": "system m5",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3650"
},
{
"model": "system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3750"
},
{
"model": "system",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3850x6"
},
{
"model": "system",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3950x6"
},
{
"model": "bladecenter hs22",
"scope": null,
"trust": 0.6,
"vendor": "lenovo",
"version": null
},
{
"model": "bladecenter hs23e",
"scope": null,
"trust": 0.6,
"vendor": "lenovo",
"version": null
},
{
"model": "flex system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x220"
},
{
"model": "flex system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x222"
},
{
"model": "flex system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x480"
},
{
"model": "flex system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x880"
},
{
"model": "idataplex dx360 m4",
"scope": null,
"trust": 0.6,
"vendor": "lenovo",
"version": null
},
{
"model": "idataplex dx360 m4 water cooled",
"scope": null,
"trust": 0.6,
"vendor": "lenovo",
"version": null
},
{
"model": "nextscale nx360 m4",
"scope": null,
"trust": 0.6,
"vendor": "lenovo",
"version": null
},
{
"model": "system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3100"
},
{
"model": "system m5",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3100"
},
{
"model": "system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3250"
},
{
"model": "system m5",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3250"
},
{
"model": "system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3300"
},
{
"model": "system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3500"
},
{
"model": "system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3550"
},
{
"model": "system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3630"
},
{
"model": "system m4 bd",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3650"
},
{
"model": "system m4 hd",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x3650"
},
{
"model": "flex system m4",
"scope": "eq",
"trust": 0.6,
"vendor": "lenovo",
"version": "x280"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:lenovo:flex_system_x240_m4_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:flex_system_x240_m5_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:flex_system_x280_x6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:flex_system_x440_m4_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:flex_system_x480_x6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:flex_system_x880_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:nextscale_nx360_m5_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:system_x3250_m6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:system_x3500_m5_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:lenovo:system_x3550_m5_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
}
]
},
"cve": "CVE-2019-6157",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2019-6157",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-13089",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-157592",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2019-6157",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "psirt@lenovo.com",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2019-6157",
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-6157",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "psirt@lenovo.com",
"id": "CVE-2019-6157",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2019-6157",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-13089",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201904-947",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-157592",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "VULHUB",
"id": "VHN-157592"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-947"
},
{
"db": "NVD",
"id": "CVE-2019-6157"
},
{
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "In various firmware versions of Lenovo System x, the integrated management module II (IMM2)\u0027s first failure data capture (FFDC) includes the web server\u0027s private key in the generated log file for support. plural Lenovo System x The product contains a vulnerability related to information disclosure from log files.Information may be obtained. LenovoFlexSystemx240M4 and so on are all servers of China Lenovo. A security vulnerability exists in several Lenovo products that originated from the FFDC recording the private key of the web server in a log file. An attacker could exploit the vulnerability to disclose information. There are security vulnerabilities in several Lenovo products. The following products are affected: Lenovo Flex System x240 M4; Flex System x240 M5; Flex System x280 X6; Flex System x440 M4; Flex System x480 X6; Flex System x880; NeXtScale nx360 M5; (ThinkAgile CX2200/4200/4600); System x3650 M5; System x3750 M4; System x3850 X6; System x3950 X6; BladeCenter HS22; BladeCenter HS23; BladeCenter HS23E; Flex System x220 M4; System x280 M4; Flex System x440 M4; Flex System x480 M4; Flex System x880 M4; iDataPlex dx360 M4; iDataPlex dx360 M4 Water Cooled; x3300 M4; System x3500 M4; System x3530 M4; System x3550 M4; System x3630 M4; System x3650 M4;",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-6157"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "VULHUB",
"id": "VHN-157592"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-6157",
"trust": 3.1
},
{
"db": "LENOVO",
"id": "LEN-25667",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201904-947",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-13089",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2019.1427",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-157592",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "VULHUB",
"id": "VHN-157592"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-947"
},
{
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"id": "VAR-201904-0089",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "VULHUB",
"id": "VHN-157592"
}
],
"trust": 1.4043650806666665
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
}
]
},
"last_update_date": "2024-11-23T21:24:47.112000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "LEN-25667",
"trust": 0.8,
"url": "https://support.lenovo.com/jp/ja/solutions/len-25667"
},
{
"title": "Patches for several Lenovo product information disclosure vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/160245"
},
{
"title": "Multiple Lenovo Product security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=91767"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-947"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-532",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-157592"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-6157"
},
{
"trust": 1.7,
"url": "https://support.lenovo.com/solutions/len-25667"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6157"
},
{
"trust": 0.6,
"url": "http://www.ibm.com/support/docview.wss"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/79722"
},
{
"trust": 0.6,
"url": "https://www-01.ibm.com/support/docview.wss?uid=ibm10882394"
},
{
"trust": 0.6,
"url": "https://support.lenovo.com/us/en/solutions/len-25667"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "VULHUB",
"id": "VHN-157592"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-947"
},
{
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"db": "VULHUB",
"id": "VHN-157592"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"db": "CNNVD",
"id": "CNNVD-201904-947"
},
{
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"date": "2019-04-22T00:00:00",
"db": "VULHUB",
"id": "VHN-157592"
},
{
"date": "2019-05-31T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"date": "2019-04-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-947"
},
{
"date": "2019-04-22T16:29:02.037000",
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-05-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-13089"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-157592"
},
{
"date": "2019-05-31T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004354"
},
{
"date": "2019-10-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201904-947"
},
{
"date": "2024-11-21T04:46:02.860000",
"db": "NVD",
"id": "CVE-2019-6157"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-947"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Lenovo System x Vulnerability related to information leakage from log files in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004354"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "log information leak",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201904-947"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.