VAR-201903-0646
Vulnerability from variot - Updated: 2024-11-23 22:21A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version. Schneider Electric OFS Contains a vulnerability related to uncontrolled search path elements.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Schneider Electric OPC Factory Server (OFS) is a data communication editing software. The software supports important information access, open page design, transparent architecture and interoperability, etc., to enable users to obtain good processes and communication effects.
Schneider Electric OFS has security vulnerabilities in loading DLLs, allowing remote attackers to use the vulnerabilities to submit special files and load them to execute arbitrary code
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0646",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "opc factory server",
"scope": "eq",
"trust": 2.1,
"vendor": "schneider electric",
"version": "3.5"
},
{
"model": "electric opc factory server sp6",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "3.5"
},
{
"model": "opc factory server",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "3.4"
},
{
"model": "opc factory server sp6",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "3.5"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "BID",
"id": "74772"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:opc_factory_server",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ivan Sanchez from Nullcode Team",
"sources": [
{
"db": "BID",
"id": "74772"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
}
],
"trust": 0.9
},
"cve": "CVE-2015-1014",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"id": "CVE-2015-1014",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2015-03451",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"id": "VHN-78974",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.3,
"id": "CVE-2015-1014",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2015-1014",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2015-1014",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2015-03451",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201505-506",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-78974",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "VULHUB",
"id": "VHN-78974"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
},
{
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version. Schneider Electric OFS Contains a vulnerability related to uncontrolled search path elements.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Schneider Electric OPC Factory Server (OFS) is a data communication editing software. The software supports important information access, open page design, transparent architecture and interoperability, etc., to enable users to obtain good processes and communication effects. \n\nSchneider Electric OFS has security vulnerabilities in loading DLLs, allowing remote attackers to use the vulnerabilities to submit special files and load them to execute arbitrary code",
"sources": [
{
"db": "NVD",
"id": "CVE-2015-1014"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "BID",
"id": "74772"
},
{
"db": "VULHUB",
"id": "VHN-78974"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2015-1014",
"trust": 3.4
},
{
"db": "ICS CERT",
"id": "ICSA-15-141-01",
"trust": 2.8
},
{
"db": "BID",
"id": "74772",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2015-03451",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-78974",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "VULHUB",
"id": "VHN-78974"
},
{
"db": "BID",
"id": "74772"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
},
{
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"id": "VAR-201903-0646",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "VULHUB",
"id": "VHN-78974"
}
],
"trust": 1.49166665
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
}
]
},
"last_update_date": "2024-11-23T22:21:45.328000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.schneider-electric.us/en/"
},
{
"title": "Patch for Schneider Electric OPC Factory Server DLL Load Arbitrary Code Execution Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/59058"
},
{
"title": "Schneider Electric OPC Factory Server Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=90843"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-427",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-78974"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-141-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2015-1014"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-1014"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/74772"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/products/ww/en/2400-industrial-communication/2450-software-for-networks/547-opc-factory-server/"
},
{
"trust": 0.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-141-01#footnoteb_0dado2g"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "VULHUB",
"id": "VHN-78974"
},
{
"db": "BID",
"id": "74772"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
},
{
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"db": "VULHUB",
"id": "VHN-78974"
},
{
"db": "BID",
"id": "74772"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
},
{
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-05-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"date": "2019-03-25T00:00:00",
"db": "VULHUB",
"id": "VHN-78974"
},
{
"date": "2015-05-21T00:00:00",
"db": "BID",
"id": "74772"
},
{
"date": "2019-05-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"date": "2015-05-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201505-506"
},
{
"date": "2019-03-25T19:29:00.337000",
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-05-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03451"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-78974"
},
{
"date": "2015-05-21T00:00:00",
"db": "BID",
"id": "74772"
},
{
"date": "2019-05-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-008253"
},
{
"date": "2019-10-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201505-506"
},
{
"date": "2024-11-21T02:24:29.743000",
"db": "NVD",
"id": "CVE-2015-1014"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "74772"
},
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric OFS Vulnerabilities in uncontrolled search path elements",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-008253"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201505-506"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.