VAR-201903-0364

Vulnerability from variot - Updated: 2024-11-23 21:37

The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to authenticated command injection via crafted HTTP request sent by a remote, authenticated attacker to /GponForm/device_Form?script/. Alcatel Lucent I-240W-Q GPON ONT Has a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. GPON (Gigabit-CapablePON) technology is the latest generation of broadband passive optical integrated access standard based on ITU-TG.984.x standard. It has many advantages such as high bandwidth, high efficiency, large coverage, rich user interface, etc. Operators are regarded as the ideal technology to realize broadband and integrated transformation of access network services. GPONHomeGateway is a router provided by ISPs for users. A remote command execution vulnerability exists in the GPON router that an attacker can use to execute arbitrary commands. Nokia Alcatel Lucent I-240W-Q GPON ONT is an optical network interruption device of Nokia Corporation of Finland

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201903-0364",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "i-240w-q gpon ont",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "nokia",
        "version": "3fe54567bozj19"
      },
      {
        "model": "networks gpon home gateway",
        "scope": null,
        "trust": 0.6,
        "vendor": "dasan",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:nokia:i-240w-q_gpon_ont_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      }
    ]
  },
  "cve": "CVE-2019-3920",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2019-3920",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-06036",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "VHN-155355",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2019-3920",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-3920",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-3920",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-3920",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-06036",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201903-080",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-155355",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "db": "VULHUB",
        "id": "VHN-155355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 is vulnerable to authenticated command injection via crafted HTTP request sent by a remote, authenticated attacker to /GponForm/device_Form?script/. Alcatel Lucent I-240W-Q GPON ONT Has a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. GPON (Gigabit-CapablePON) technology is the latest generation of broadband passive optical integrated access standard based on ITU-TG.984.x standard. It has many advantages such as high bandwidth, high efficiency, large coverage, rich user interface, etc. Operators are regarded as the ideal technology to realize broadband and integrated transformation of access network services. GPONHomeGateway is a router provided by ISPs for users. A remote command execution vulnerability exists in the GPON router that an attacker can use to execute arbitrary commands. Nokia Alcatel Lucent I-240W-Q GPON ONT is an optical network interruption device of Nokia Corporation of Finland",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-3920"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "db": "VULHUB",
        "id": "VHN-155355"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-3920",
        "trust": 3.1
      },
      {
        "db": "TENABLE",
        "id": "TRA-2019-09",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-080",
        "trust": 0.7
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-978",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-155355",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "db": "VULHUB",
        "id": "VHN-155355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "id": "VAR-201903-0364",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "db": "VULHUB",
        "id": "VHN-155355"
      }
    ],
    "trust": 1.7
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:37:36.510000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.nokia.com/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-155355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.tenable.com/security/research/tra-2019-09"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3920"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3920"
      },
      {
        "trust": 0.6,
        "url": "https://www.seebug.org/vuldb/ssvid-978"
      },
      {
        "trust": 0.6,
        "url": "https://www.zoomeye.org/searchresult?q=%22gpon%20home%20gateway%"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "db": "VULHUB",
        "id": "VHN-155355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "db": "VULHUB",
        "id": "VHN-155355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-03-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "date": "2019-03-05T00:00:00",
        "db": "VULHUB",
        "id": "VHN-155355"
      },
      {
        "date": "2019-04-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "date": "2019-03-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      },
      {
        "date": "2019-03-05T21:29:00.413000",
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-04-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-06036"
      },
      {
        "date": "2022-12-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-155355"
      },
      {
        "date": "2019-04-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      },
      {
        "date": "2019-03-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      },
      {
        "date": "2024-11-21T04:42:51.970000",
        "db": "NVD",
        "id": "CVE-2019-3920"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Alcatel Lucent I-240W-Q GPON ONT Command injection vulnerability in some firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-002215"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201903-080"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…