VAR-201903-0361
Vulnerability from variot - Updated: 2024-11-23 21:37The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 allows a remote, unauthenticated attacker to enable telnetd on the router via a crafted HTTP request. Alcatel Lucent I-240W-Q GPON ONT There is an access control vulnerability in the firmware.Information may be tampered with. GPON (Gigabit-CapablePON) technology is the latest generation of broadband passive optical integrated access standard based on ITU-TG.984.x standard. It has many advantages such as high bandwidth, high efficiency, large coverage, rich user interface, etc. Operators are regarded as the ideal technology to realize broadband and integrated transformation of access network services. GPONHomeGateway is a router provided by ISPs for users. The GPON router has a remote unauthenticated enable/disable Telnet service vulnerability that can be exploited by an attacker to enable/disable the Telnet service without authentication. Nokia Alcatel Lucent I-240W-Q GPON ONT is an optical network interruption device of Nokia Corporation of Finland. A security vulnerability exists in Nokia Alcatel Lucent I-240W-Q GPON ONTs using firmware version 3FE54567BOZJ19
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0361",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "i-240w-q gpon ont",
"scope": "eq",
"trust": 1.8,
"vendor": "nokia",
"version": "3fe54567bozj19"
},
{
"model": "networks gpon home gateway",
"scope": null,
"trust": 0.6,
"vendor": "dasan",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:nokia:i-240w-q_gpon_ont_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
}
]
},
"cve": "CVE-2019-3917",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2019-3917",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-06040",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-155352",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2019-3917",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-3917",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-3917",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2019-3917",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-06040",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201903-077",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-155352",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"db": "VULHUB",
"id": "VHN-155352"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-077"
},
{
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Alcatel Lucent I-240W-Q GPON ONT using firmware version 3FE54567BOZJ19 allows a remote, unauthenticated attacker to enable telnetd on the router via a crafted HTTP request. Alcatel Lucent I-240W-Q GPON ONT There is an access control vulnerability in the firmware.Information may be tampered with. GPON (Gigabit-CapablePON) technology is the latest generation of broadband passive optical integrated access standard based on ITU-TG.984.x standard. It has many advantages such as high bandwidth, high efficiency, large coverage, rich user interface, etc. Operators are regarded as the ideal technology to realize broadband and integrated transformation of access network services. GPONHomeGateway is a router provided by ISPs for users. The GPON router has a remote unauthenticated enable/disable Telnet service vulnerability that can be exploited by an attacker to enable/disable the Telnet service without authentication. Nokia Alcatel Lucent I-240W-Q GPON ONT is an optical network interruption device of Nokia Corporation of Finland. A security vulnerability exists in Nokia Alcatel Lucent I-240W-Q GPON ONTs using firmware version 3FE54567BOZJ19",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-3917"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"db": "VULHUB",
"id": "VHN-155352"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-3917",
"trust": 3.1
},
{
"db": "TENABLE",
"id": "TRA-2019-09",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201903-077",
"trust": 0.7
},
{
"db": "SEEBUG",
"id": "SSVID-978",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2019-06040",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-155352",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"db": "VULHUB",
"id": "VHN-155352"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-077"
},
{
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"id": "VAR-201903-0361",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"db": "VULHUB",
"id": "VHN-155352"
}
],
"trust": 1.7
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06040"
}
]
},
"last_update_date": "2024-11-23T21:37:36.417000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.nokia.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-425",
"trust": 1.1
},
{
"problemtype": "CWE-306",
"trust": 1.0
},
{
"problemtype": "CWE-284",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-155352"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.tenable.com/security/research/tra-2019-09"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-3917"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-3917"
},
{
"trust": 0.6,
"url": "https://www.seebug.org/vuldb/ssvid-978"
},
{
"trust": 0.6,
"url": "https://www.zoomeye.org/searchresult?q=%22gpon%20home%20gateway%"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"db": "VULHUB",
"id": "VHN-155352"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-077"
},
{
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"db": "VULHUB",
"id": "VHN-155352"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-077"
},
{
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"date": "2019-03-05T00:00:00",
"db": "VULHUB",
"id": "VHN-155352"
},
{
"date": "2019-04-04T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"date": "2019-03-05T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-077"
},
{
"date": "2019-03-05T21:29:00.290000",
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-04-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-06040"
},
{
"date": "2020-10-19T00:00:00",
"db": "VULHUB",
"id": "VHN-155352"
},
{
"date": "2019-04-04T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-002212"
},
{
"date": "2020-10-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-077"
},
{
"date": "2024-11-21T04:42:51.600000",
"db": "NVD",
"id": "CVE-2019-3917"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-077"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Alcatel Lucent I-240W-Q GPON ONT Vulnerabilities related to access control in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-002212"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-077"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.