VAR-201902-0726
Vulnerability from variot - Updated: 2024-11-23 22:30The web interface on FASTGate Fastweb devices with firmware through 0.00.47_FW_200_Askey 2017-05-17 (software through 1.0.1b) exposed a CGI binary that is vulnerable to a command injection vulnerability that can be exploited to achieve remote code execution with root privileges. No authentication is required in order to trigger the vulnerability. FASTGate Fastweb The device firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201902-0726",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fastgate",
"scope": "lte",
"trust": 1.8,
"vendor": "fastweb",
"version": "1.0.1b"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:fastweb:fastgate_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
}
]
},
"cve": "CVE-2018-20122",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2018-20122",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-130897",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2018-20122",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-20122",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2018-20122",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-201902-816",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-130897",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-20122",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-130897"
},
{
"db": "VULMON",
"id": "CVE-2018-20122"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-816"
},
{
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The web interface on FASTGate Fastweb devices with firmware through 0.00.47_FW_200_Askey 2017-05-17 (software through 1.0.1b) exposed a CGI binary that is vulnerable to a command injection vulnerability that can be exploited to achieve remote code execution with root privileges. No authentication is required in order to trigger the vulnerability. FASTGate Fastweb The device firmware contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-20122"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"db": "VULHUB",
"id": "VHN-130897"
},
{
"db": "VULMON",
"id": "CVE-2018-20122"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-20122",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014614",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201902-816",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-130897",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-20122",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-130897"
},
{
"db": "VULMON",
"id": "CVE-2018-20122"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-816"
},
{
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"id": "VAR-201902-0726",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-130897"
}
],
"trust": 0.6625
},
"last_update_date": "2024-11-23T22:30:08.402000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "FASTGATE",
"trust": 0.8,
"url": "https://www.fastweb.it/adsl-fibra-ottica/dettagli/modem-fastweb-fastgate/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-130897"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://www.horizonsecurity.it/advisories/?a=12\u0026title=fastweb+fastgate+router+101b+remote+code+execution++cve201820122"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-20122"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-20122"
},
{
"trust": 0.1,
"url": "http://www.horizonsecurity.it/advisories/?a=12\u0026amp;title=fastweb+fastgate+router+101b+remote+code+execution++cve201820122"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-130897"
},
{
"db": "VULMON",
"id": "CVE-2018-20122"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-816"
},
{
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-130897"
},
{
"db": "VULMON",
"id": "CVE-2018-20122"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-816"
},
{
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-02-21T00:00:00",
"db": "VULHUB",
"id": "VHN-130897"
},
{
"date": "2019-02-21T00:00:00",
"db": "VULMON",
"id": "CVE-2018-20122"
},
{
"date": "2019-03-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"date": "2019-02-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201902-816"
},
{
"date": "2019-02-21T14:29:00.313000",
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-130897"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2018-20122"
},
{
"date": "2019-03-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014614"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201902-816"
},
{
"date": "2024-11-21T04:00:53.933000",
"db": "NVD",
"id": "CVE-2018-20122"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201902-816"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "FASTGate Fastweb Command injection vulnerability in device firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014614"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201902-816"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…