VAR-201812-0346

Vulnerability from variot - Updated: 2024-11-23 22:37

A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known. SIMATIC S7-1200 and SIMATIC S7-1500 Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens SIMATIC S7-1200 and SIMATIC S7-1500 are programmable logic controllers (PLCs) from Siemens AG in small and medium-sized automation systems. Siemens SIMATIC S7 is prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0346",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "2.6"
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.8.3"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.7"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.6"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.5.0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.6"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "BID",
        "id": "105928"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Younes Dragoni of Nozomi Networks",
    "sources": [
      {
        "db": "BID",
        "id": "105928"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-13815",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-13815",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-25436",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-123912",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-13815",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-13815",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-13815",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-25436",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201811-486",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-123912",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123912"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions \u003c V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known. SIMATIC S7-1200 and SIMATIC S7-1500 Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens SIMATIC S7-1200 and SIMATIC S7-1500 are programmable logic controllers (PLCs) from Siemens AG in small and medium-sized automation systems. Siemens SIMATIC S7 is prone to a denial-of-service vulnerability. \nRemote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-13815"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "BID",
        "id": "105928"
      },
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123912"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-13815",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-317-05",
        "trust": 2.3
      },
      {
        "db": "BID",
        "id": "105928",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-584286",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "7D80FC81-463F-11E9-8E8E-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-98855",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-123912",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123912"
      },
      {
        "db": "BID",
        "id": "105928"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "id": "VAR-201812-0346",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123912"
      }
    ],
    "trust": 1.567001695
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:37:57.648000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-584286",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf"
      },
      {
        "title": "Patch for SiemensSIMATICS7-1200 and SIMATICS7-1500 denial of service vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/147357"
      },
      {
        "title": "Siemens SIMATIC S7-1200  and SIMATIC S7-1500 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86887"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-410",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123912"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-05"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/105928"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13815"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13815"
      },
      {
        "trust": 0.3,
        "url": "http://www.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123912"
      },
      {
        "db": "BID",
        "id": "105928"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123912"
      },
      {
        "db": "BID",
        "id": "105928"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-14T00:00:00",
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123912"
      },
      {
        "date": "2018-11-13T00:00:00",
        "db": "BID",
        "id": "105928"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      },
      {
        "date": "2018-12-13T16:29:00.383000",
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-25436"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123912"
      },
      {
        "date": "2018-11-13T00:00:00",
        "db": "BID",
        "id": "105928"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      },
      {
        "date": "2024-11-21T03:48:07.740000",
        "db": "NVD",
        "id": "CVE-2018-13815"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SIMATIC S7-1200 and  SIMATIC S7-1500 Vulnerable to resource exhaustion",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014528"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Resource management error",
    "sources": [
      {
        "db": "IVD",
        "id": "7d80fc81-463f-11e9-8e8e-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-486"
      }
    ],
    "trust": 0.8
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…