Vulnerability from variot - Updated: 2024-11-23 22:17A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany's Siemens (Siemens) company HMI software for control and monitoring of machines and equipment.
The webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities: 1. An open-redirection vulnerability 2. A directory-traversal vulnerability Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201812-0344",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc runtime",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi mp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi op",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi comfort panels",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic wincc \\",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi tp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi comfort panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime advanced",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi classic devices",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi comfort outdoor panels 7\" \u0026 15\" update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort panels 4\"-22\" update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi ktp mobile panels update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime advanced update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime professional update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "simatic wincc runtime",
"version": "*"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "1319"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime advanced sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced sp1 upd5",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v135"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v12"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v120"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v110"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v15"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v136"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v10"
},
{
"model": "simatic hmi ktp mobile panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "22"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic hmi comfort panels sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic hmi comfort panels sp1 upd5",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi classic devices",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc runtime professional update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime advanced update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi ktp mobile panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort outdoor panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi comfort panels",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi mp",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi op",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi comfort outdoor panels",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp400f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp700",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp700f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp900",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp900f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi tp",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Hosni Tounsi from Carthage Red Team",
"sources": [
{
"db": "BID",
"id": "105922"
}
],
"trust": 0.3
},
"cve": "CVE-2018-13813",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2018-13813",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-24247",
"impactScore": 6.9,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1",
"impactScore": 6.9,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-123910",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2018-13813",
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-13813",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-13813",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2018-24247",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201811-483",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-123910",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany\u0027s Siemens (Siemens) company HMI software for control and monitoring of machines and equipment. \n\nThe webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities:\n1. An open-redirection vulnerability\n2. A directory-traversal vulnerability\nRemote attackers may use a specially crafted request with directory-traversal sequences (\u0027../\u0027) to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-123910"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-13813",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-233109",
"trust": 2.3
},
{
"db": "ICS CERT",
"id": "ICSA-18-317-08",
"trust": 2.3
},
{
"db": "BID",
"id": "105922",
"trust": 2.0
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2018-24247",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526",
"trust": 0.8
},
{
"db": "IVD",
"id": "E30112C1-39AB-11E9-9EAE-000C29342CB1",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-123910",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"id": "VAR-201812-0344",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
}
],
"trust": 1.59438617
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
}
]
},
"last_update_date": "2024-11-23T22:17:14.847000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-233109",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
},
{
"title": "Patch for Multiple Siemens products open redirection vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/176377"
},
{
"title": "Multiple Siemens Product security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86884"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-601",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
},
{
"trust": 2.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-08"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/105922"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13813"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-13813"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-11-29T00:00:00",
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"date": "2018-11-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"date": "2018-12-13T00:00:00",
"db": "VULHUB",
"id": "VHN-123910"
},
{
"date": "2018-11-14T00:00:00",
"db": "BID",
"id": "105922"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"date": "2018-11-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-483"
},
{
"date": "2018-12-13T16:29:00.320000",
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-08-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-123910"
},
{
"date": "2018-11-14T00:00:00",
"db": "BID",
"id": "105922"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-483"
},
{
"date": "2024-11-21T03:48:07.380000",
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural SIMATIC Open redirect vulnerability in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation error",
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
],
"trust": 1.1
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.