VAR-201809-0169

Vulnerability from variot - Updated: 2024-11-23 23:02

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service). VIVOTEK FD8177 The device contains a command injection vulnerability.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. VIVOTEKFD8177 is a network camera product from Vivotek. There is a security vulnerability in VIVOTEK FD8177 prior to XXXXXX-VVTK-xx06a

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0169",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "camera",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "vivotek",
        "version": null
      },
      {
        "model": "camera",
        "scope": null,
        "trust": 0.8,
        "vendor": "vivotek",
        "version": null
      },
      {
        "model": "fd8177 \u003cxxxxxx-vvtk-xx06a",
        "scope": null,
        "trust": 0.6,
        "vendor": "vivotek",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/h:vivotek:camera",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      }
    ]
  },
  "cve": "CVE-2018-14770",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2018-14770",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2019-06203",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "VHN-124963",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2018-14770",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-14770",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-14770",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-06203",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-208",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-124963",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124963"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service). VIVOTEK FD8177 The device contains a command injection vulnerability.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. VIVOTEKFD8177 is a network camera product from Vivotek. There is a security vulnerability in VIVOTEK FD8177 prior to XXXXXX-VVTK-xx06a",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-14770"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124963"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-14770",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-124963",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124963"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "id": "VAR-201809-0169",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124963"
      }
    ],
    "trust": 1.6391892
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:02:01.531000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "VVTK-SA-2018-003",
        "trust": 0.8,
        "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
      },
      {
        "title": "Cybersecurity",
        "trust": 0.8,
        "url": "https://www.vivotek.com/website/support/cybersecurity/"
      },
      {
        "title": "Patch for VIVOTEKFD8177 Command Injection Vulnerability (CNVD-2019-06203)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/155265"
      },
      {
        "title": "VIVOTEK FD8177 Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84544"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-77",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-124963"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://www.vivotek.com/website/support/cybersecurity/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14770"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14770"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124963"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "db": "VULHUB",
        "id": "VHN-124963"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-03-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "date": "2018-09-05T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124963"
      },
      {
        "date": "2018-12-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "date": "2018-09-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      },
      {
        "date": "2018-09-05T21:29:00.780000",
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-03-06T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-06203"
      },
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-124963"
      },
      {
        "date": "2018-12-11T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      },
      {
        "date": "2020-10-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      },
      {
        "date": "2024-11-21T03:49:45.070000",
        "db": "NVD",
        "id": "CVE-2018-14770"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "VIVOTEK FD8177 Command injection vulnerabilities in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-010298"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-208"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.