VAR-201807-1854
Vulnerability from variot - Updated: 2024-11-23 22:17In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation. SchneiderElectricPelcoSarixProfessional1stgenerationcameras is an IP camera device from Schneider Electric, France. A security vulnerability exists in Schneider Electric PelcoSarix Professional1stgenerationcameras using firmware prior to 3.29.69
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201807-1854",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "imps110-1",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "ibp1110-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp1110-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp519-1e",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "ibp219-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "ibp319-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "ibp519-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imps110-1e",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp219-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp319-1",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp519-1",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp219-1e",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp319-1e",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "ibps110-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp1110-1",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp519-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp319-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp219-1",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imps110-1er",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "imp1110-1e",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "pelco sarix pro 1 st generation",
"scope": "lt",
"trust": 0.8,
"vendor": "schneider electric",
"version": "3.29.69"
},
{
"model": "electric pelco sarix professional 1st generation cameras",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "3.29.69"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:schneider_electric:pelco_sarix_professional_1st_generation_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
}
]
},
"cve": "CVE-2018-7781",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2018-7781",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-05104",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2018-7781",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-7781",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-7781",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-05104",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201807-145",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-145"
},
{
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation. SchneiderElectricPelcoSarixProfessional1stgenerationcameras is an IP camera device from Schneider Electric, France. A security vulnerability exists in Schneider Electric PelcoSarix Professional1stgenerationcameras using firmware prior to 3.29.69",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-7781"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "CNVD",
"id": "CNVD-2019-05104"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-7781",
"trust": 3.0
},
{
"db": "SCHNEIDER",
"id": "SEVD-2018-114-01",
"trust": 2.2
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-05104",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201807-145",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-145"
},
{
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"id": "VAR-201807-1854",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
}
]
},
"last_update_date": "2024-11-23T22:17:25.547000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2018-114-01",
"trust": 0.8,
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2018-114-01+Pelco+Sarix+Pro1.pdf\u0026p_Doc_Ref=SEVD-2018-114-01"
},
{
"title": "SchneiderElectricPelcoSarixProfessional1stgenerationcameras privilege escalation vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/154305"
},
{
"title": "Schneider Electric Pelco Sarix Professional 1st generation cameras Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=81714"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-145"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-311",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://www.schneider-electric.com/en/download/document/sevd-2018-114-01/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7781"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-7781"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-145"
},
{
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"db": "CNNVD",
"id": "CNNVD-201807-145"
},
{
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-02-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"date": "2018-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"date": "2018-07-04T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201807-145"
},
{
"date": "2018-07-03T14:29:01.383000",
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-02-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-05104"
},
{
"date": "2018-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-007800"
},
{
"date": "2019-10-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201807-145"
},
{
"date": "2024-11-21T04:12:43.390000",
"db": "NVD",
"id": "CVE-2018-7781"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201807-145"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Pelco Sarix Professional 1st generation Vulnerabilities related to authorization, authority, and access control in camera firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-007800"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201807-145"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…