VAR-201806-1136

Vulnerability from variot - Updated: 2024-11-23 23:02

Emerson Liebert IntelliSlot Web Card devices allow remote attackers to reconfigure access control via the config/configUser.htm or config/configTelnet.htm URI. EmersonLiebertIntelliSlotWebCarddevices is an intelligent network card product from Emerson Electric. A security vulnerability exists in the EmersonLiebert IntelliSlotWebCard device

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201806-1136",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "liebert intellislot",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "vertiv",
        "version": null
      },
      {
        "model": "liebert intellislot",
        "scope": null,
        "trust": 0.8,
        "vendor": "vertiv",
        "version": null
      },
      {
        "model": "liebert liebert intellislot web card devices",
        "scope": null,
        "trust": 0.6,
        "vendor": "emerson",
        "version": null
      },
      {
        "model": "liebert intellislot",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "vertivco",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:vertivco:liebert_intellislot_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      }
    ]
  },
  "cve": "CVE-2018-12922",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-12922",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-12418",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-122930",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-12922",
            "impactScore": 3.6,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2018-12922",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-12922",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-12922",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-12418",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201806-1409",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-122930",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "db": "VULHUB",
        "id": "VHN-122930"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Emerson Liebert IntelliSlot Web Card devices allow remote attackers to reconfigure access control via the config/configUser.htm or config/configTelnet.htm URI. EmersonLiebertIntelliSlotWebCarddevices is an intelligent network card product from Emerson Electric. A security vulnerability exists in the EmersonLiebert IntelliSlotWebCard device",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-12922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "db": "VULHUB",
        "id": "VHN-122930"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-12922",
        "trust": 3.1
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-97372",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-122930",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "db": "VULHUB",
        "id": "VHN-122930"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "id": "VAR-201806-1136",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "db": "VULHUB",
        "id": "VHN-122930"
      }
    ],
    "trust": 1.7
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      }
    ]
  },
  "last_update_date": "2024-11-23T23:02:08.169000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.vertivco.com/en-us/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-732",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-284",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-122930"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.seebug.org/vuldb/ssvid-97372"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-12922"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-12922"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "db": "VULHUB",
        "id": "VHN-122930"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "db": "VULHUB",
        "id": "VHN-122930"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-07-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "date": "2018-06-28T00:00:00",
        "db": "VULHUB",
        "id": "VHN-122930"
      },
      {
        "date": "2018-09-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "date": "2018-06-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      },
      {
        "date": "2018-06-28T11:29:00.303000",
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-07-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-12418"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-122930"
      },
      {
        "date": "2018-09-06T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      },
      {
        "date": "2024-11-21T03:46:07.063000",
        "db": "NVD",
        "id": "CVE-2018-12922"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Emerson Liebert IntelliSlot Web Card Device access control vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-007045"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "lack of information",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201806-1409"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…