VAR-201805-0837
Vulnerability from variot - Updated: 2025-01-30 20:33SimpliSafe Original has Unencrypted Sensor Transmissions, which allows physically proximate attackers to obtain potentially sensitive information about the specific times when alarm-system events occur. SimpliSafe Original Contains an information disclosure vulnerability.Information may be obtained. SimpliSafe Original is a home security management system. The system includes video surveillance and intrusion alarms, among other things. A security flaw exists in SimpliSafe Original, which stems from the program not encrypting the messages passed. An attacker in physical proximity could exploit this vulnerability to obtain sensitive information
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201805-0837",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "u9k-wt1000",
"scope": "eq",
"trust": 1.6,
"vendor": "simplisafe",
"version": null
},
{
"model": "u9k-es1000",
"scope": "eq",
"trust": 1.6,
"vendor": "simplisafe",
"version": null
},
{
"model": "u9k-ms1000",
"scope": "eq",
"trust": 1.6,
"vendor": "simplisafe",
"version": null
},
{
"model": "u9k-kr1",
"scope": "eq",
"trust": 1.6,
"vendor": "simplisafe",
"version": null
},
{
"model": "u9k-es1000",
"scope": null,
"trust": 0.8,
"vendor": "simplisafe",
"version": null
},
{
"model": "u9k-kr1",
"scope": null,
"trust": 0.8,
"vendor": "simplisafe",
"version": null
},
{
"model": "u9k-ms1000",
"scope": null,
"trust": 0.8,
"vendor": "simplisafe",
"version": null
},
{
"model": "u9k-wt1000",
"scope": null,
"trust": 0.8,
"vendor": "simplisafe",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-845"
},
{
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:simplisafe:u9k-es1000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:simplisafe:u9k-kr1_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:simplisafe:u9k-ms1000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:simplisafe:u9k-wt1000_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
}
]
},
"cve": "CVE-2018-11399",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"id": "CVE-2018-11399",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.9,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"id": "VHN-121254",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:L/AC:M/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.7,
"id": "CVE-2018-11399",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-11399",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2018-11399",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-201805-845",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-121254",
"trust": 0.1,
"value": "LOW"
},
{
"author": "VULMON",
"id": "CVE-2018-11399",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-121254"
},
{
"db": "VULMON",
"id": "CVE-2018-11399"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-845"
},
{
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SimpliSafe Original has Unencrypted Sensor Transmissions, which allows physically proximate attackers to obtain potentially sensitive information about the specific times when alarm-system events occur. SimpliSafe Original Contains an information disclosure vulnerability.Information may be obtained. SimpliSafe Original is a home security management system. The system includes video surveillance and intrusion alarms, among other things. A security flaw exists in SimpliSafe Original, which stems from the program not encrypting the messages passed. An attacker in physical proximity could exploit this vulnerability to obtain sensitive information",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11399"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"db": "VULHUB",
"id": "VHN-121254"
},
{
"db": "VULMON",
"id": "CVE-2018-11399"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-11399",
"trust": 2.7
},
{
"db": "JVNDB",
"id": "JVNDB-2018-005270",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201805-845",
"trust": 0.7
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-121254",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-11399",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-121254"
},
{
"db": "VULMON",
"id": "CVE-2018-11399"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-845"
},
{
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"id": "VAR-201805-0837",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-121254"
}
],
"trust": 0.02
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"embedded device"
],
"sub_category": "smart home sensor",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-01-30T20:33:18.470000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://simplisafe.com/home-security-shop-simplisafe-original"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-319",
"trust": 1.1
},
{
"problemtype": "CWE-200",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-121254"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.simpleorsecure.net/simplisafe-security-advisory/"
},
{
"trust": 1.8,
"url": "https://simplisafe.com/files/pdf/simplisafe_advisory_8-17-18.pdf"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11399"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-11399"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/319.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-121254"
},
{
"db": "VULMON",
"id": "CVE-2018-11399"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-845"
},
{
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-121254"
},
{
"db": "VULMON",
"id": "CVE-2018-11399"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"db": "CNNVD",
"id": "CNNVD-201805-845"
},
{
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-05-24T00:00:00",
"db": "VULHUB",
"id": "VHN-121254"
},
{
"date": "2018-05-24T00:00:00",
"db": "VULMON",
"id": "CVE-2018-11399"
},
{
"date": "2018-07-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"date": "2018-05-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201805-845"
},
{
"date": "2018-05-24T05:29:00.210000",
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-03T00:00:00",
"db": "VULHUB",
"id": "VHN-121254"
},
{
"date": "2019-10-03T00:00:00",
"db": "VULMON",
"id": "CVE-2018-11399"
},
{
"date": "2018-07-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-005270"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201805-845"
},
{
"date": "2024-11-21T03:43:16.910000",
"db": "NVD",
"id": "CVE-2018-11399"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201805-845"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SimpliSafe Original Vulnerable to information disclosure",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-005270"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201805-845"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…