VAR-201802-1279
Vulnerability from variot - Updated: 2024-11-23 22:45Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device. eQ-3 AG Homematic CCU2 Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The eQ-3AGHomematicCCU2 is a central control unit for the German eQ-3 company that controls smart home devices. An attacker could exploit the vulnerability to create or overwrite any file or install malware on the device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201802-1279",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "homematic central control unit ccu2",
"scope": "lte",
"trust": 1.0,
"vendor": "eq 3",
"version": "2.29.22"
},
{
"model": "homematic zentrale ccu2",
"scope": "lte",
"trust": 0.8,
"vendor": "eq 3",
"version": "2.29.2"
},
{
"model": "ag homematic ccu2",
"scope": "lte",
"trust": 0.6,
"vendor": "eq 3",
"version": "\u003c=2.29.22"
},
{
"model": "homematic central control unit ccu2",
"scope": "eq",
"trust": 0.6,
"vendor": "eq 3",
"version": "2.29.22"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-554"
},
{
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:eq-3:homematic_central_control_unit_ccu2_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
}
]
},
"cve": "CVE-2018-7299",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CVE-2018-7299",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "CNVD-2018-05829",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.2,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 5.1,
"id": "VHN-137331",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:A/AC:L/AU:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2018-7299",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-7299",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-7299",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2018-05829",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201802-554",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-137331",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"db": "VULHUB",
"id": "VHN-137331"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-554"
},
{
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Remote Code Execution in the addon installation process in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows authenticated attackers to create or overwrite arbitrary files or install malicious software on the device. eQ-3 AG Homematic CCU2 Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The eQ-3AGHomematicCCU2 is a central control unit for the German eQ-3 company that controls smart home devices. An attacker could exploit the vulnerability to create or overwrite any file or install malware on the device",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-7299"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"db": "VULHUB",
"id": "VHN-137331"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-7299",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2018-05829",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201802-554",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-137331",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"db": "VULHUB",
"id": "VHN-137331"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-554"
},
{
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"id": "VAR-201802-1279",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"db": "VULHUB",
"id": "VHN-137331"
}
],
"trust": 1.7
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05829"
}
]
},
"last_update_date": "2024-11-23T22:45:26.158000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "HomeMatic Zentrale CCU2",
"trust": 0.8,
"url": "http://www.eq-3.de/produkte/homematic/zentralen-und-gateways/homematic-zentrale-ccu-2.html"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-137331"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "http://atomic111.github.io/article/homematic-ccu2-untrusted_addon"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7299"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-7299"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"db": "VULHUB",
"id": "VHN-137331"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-554"
},
{
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"db": "VULHUB",
"id": "VHN-137331"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-554"
},
{
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"date": "2018-02-22T00:00:00",
"db": "VULHUB",
"id": "VHN-137331"
},
{
"date": "2018-04-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"date": "2018-03-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201802-554"
},
{
"date": "2018-02-22T19:29:05.420000",
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-05829"
},
{
"date": "2019-10-03T00:00:00",
"db": "VULHUB",
"id": "VHN-137331"
},
{
"date": "2018-04-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-002465"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201802-554"
},
{
"date": "2024-11-21T04:11:57.743000",
"db": "NVD",
"id": "CVE-2018-7299"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201802-554"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "eQ-3 AG Homematic CCU2 Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-002465"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201802-554"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…