VAR-201801-1066

Vulnerability from variot - Updated: 2024-11-23 21:39

A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack. VideoXpert is a video management solution designed for scalability, suitable for any size monitoring operation. Attackers can use the vulnerabilities to obtain sensitive information. PelcoVideoXpertEnterprise is an enterprise video management system. SchneiderElectricPelcoVideoXpertEnterprise has a directory traversal vulnerability. Information harvested may aid in launching further attacks. Versions prior to Pelco VideoXpert Enterprise 2.1 are vulnerable. The vulnerability existdue to the improper permissions, with the 'F' flag (full) for the'Users' group, for several binary files. The service is installedby default to start on system boot with LocalSystem privileges.Attackers can replace the binary with their rootkit, and on rebootthey get SYSTEM privileges.

VideoXpert services also suffer from an unquoted search path issueimpacting the 'VideoXpert Core' and 'VideoXpert Exports' servicesfor Windows deployed as part of the VideoXpert Setup bundle. A successful attempt would require the local user to be able to inserttheir code in the system root path undetected by the OS or other securityapplications where it could potentially be executed during applicationstartup or reboot. If successful, the local user’s code would executewith the elevated privileges of the application.Tested on: Microsoft Windows 7 Professional SP1 (EN)

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201801-1066",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "pelco videoxpert",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "2.1"
      },
      {
        "model": "pelco videoxpert",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": "enterprise 2.1"
      },
      {
        "model": "pelco videoxpert",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": "all versions"
      },
      {
        "model": "electric pelco videoxpert",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "2.0.41"
      },
      {
        "model": "electric pelco videoxpert",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "1.14.7"
      },
      {
        "model": "electric pelco videoxpert",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "1.12.105"
      },
      {
        "model": "electric pelco videoxpert enterprise",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "2.1"
      },
      {
        "model": "pelco videoxpert enterprise",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "2.0"
      },
      {
        "model": "pelco videoxpert enterprise",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "schneider electric",
        "version": "2.1"
      },
      {
        "model": "pelco videoxpert missing encryption of sensitive information",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "2.0.41"
      },
      {
        "model": "pelco videoxpert missing encryption of sensitive information",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "1.14.7"
      },
      {
        "model": "pelco videoxpert missing encryption of sensitive information",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "1.12.105"
      },
      {
        "model": "pelco videoxpert core admin portal directory traversal",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "2.0.41"
      },
      {
        "model": "pelco videoxpert core admin portal directory traversal",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "1.14.7"
      },
      {
        "model": "pelco videoxpert core admin portal directory traversal",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "1.12.105"
      },
      {
        "model": "pelco videoxpert privilege escalations",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "core software 1.12.105"
      },
      {
        "model": "pelco videoxpert privilege escalations",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "media gateway software 1.12.26"
      },
      {
        "model": "pelco videoxpert privilege escalations",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "schneider electric se",
        "version": "exports 1.12"
      }
    ],
    "sources": [
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "db": "BID",
        "id": "102338"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:schneider_electric:pelco_videoxpert",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability discovered by Gjoko Krstic",
    "sources": [
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-9964",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2017-9964",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2017-23308",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 4.9,
            "id": "CNVD-2017-38302",
            "impactScore": 7.8,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:N/C:P/I:C/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.6,
            "id": "CVE-2017-9964",
            "impactScore": 4.7,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-9964",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-9964",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-23308",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-38302",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201706-1084",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "ZSL",
            "id": "ZSL-2017-5420",
            "trust": 0.1,
            "value": "(3/5)"
          },
          {
            "author": "ZSL",
            "id": "ZSL-2017-5419",
            "trust": 0.1,
            "value": "(4/5)"
          },
          {
            "author": "ZSL",
            "id": "ZSL-2017-5418",
            "trust": 0.1,
            "value": "(3/5)"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack. VideoXpert is a video management solution designed for scalability, suitable for any size monitoring operation. Attackers can use the vulnerabilities to obtain sensitive information. PelcoVideoXpertEnterprise is an enterprise video management system. SchneiderElectricPelcoVideoXpertEnterprise has a directory traversal vulnerability.  Information harvested may aid in launching further attacks. \nVersions prior to Pelco VideoXpert Enterprise 2.1 are vulnerable. The vulnerability existdue to the improper permissions, with the \u0027F\u0027 flag (full) for the\u0027Users\u0027 group, for several binary files. The service is installedby default to start on system boot with LocalSystem privileges.Attackers can replace the binary with their rootkit, and on rebootthey get SYSTEM privileges.\u003cbr/\u003e\u003cbr/\u003eVideoXpert services also suffer from an unquoted search path issueimpacting the \u0027VideoXpert Core\u0027 and \u0027VideoXpert Exports\u0027 servicesfor Windows deployed as part of the VideoXpert Setup bundle. A successful attempt would require the local user to be able to inserttheir code in the system root path undetected by the OS or other securityapplications where it could potentially be executed during applicationstartup or reboot. If successful, the local user\u2019s code would executewith the elevated privileges of the application.Tested on: Microsoft Windows 7 Professional SP1 (EN)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-9964"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "db": "BID",
        "id": "102338"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      }
    ],
    "trust": 3.24
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.zeroscience.mk/codes/pelcovideoxpert_cookie.txt",
        "trust": 0.1,
        "type": "poc"
      },
      {
        "reference": "https://www.zeroscience.mk/codes/pelcovideoxpert_fd.txt",
        "trust": 0.1,
        "type": "poc"
      },
      {
        "reference": "https://www.zeroscience.mk/codes/pelcovideoxpert_eop.txt",
        "trust": 0.1,
        "type": "poc"
      }
    ],
    "sources": [
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "ICS CERT",
        "id": "ICSA-17-355-02",
        "trust": 3.6
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9964",
        "trust": 3.4
      },
      {
        "db": "BID",
        "id": "102338",
        "trust": 1.6
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2017-339-01",
        "trust": 1.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851",
        "trust": 0.8
      },
      {
        "db": "EXPLOIT-DB",
        "id": "42312",
        "trust": 0.7
      },
      {
        "db": "EXPLOITDB",
        "id": "42312",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302",
        "trust": 0.6
      },
      {
        "db": "NSFOCUS",
        "id": "38558",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2017122204",
        "trust": 0.3
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419",
        "trust": 0.2
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2018.0004",
        "trust": 0.1
      },
      {
        "db": "CXSECURITY",
        "id": "WLB-2017070079",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "143318",
        "trust": 0.1
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420",
        "trust": 0.1
      },
      {
        "db": "CXSECURITY",
        "id": "WLB-2017070077",
        "trust": 0.1
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9965",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "143317",
        "trust": 0.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "42311",
        "trust": 0.1
      },
      {
        "db": "CXSECURITY",
        "id": "WLB-2017070078",
        "trust": 0.1
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9966",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "143316",
        "trust": 0.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "42310",
        "trust": 0.1
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "db": "BID",
        "id": "102338"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "id": "VAR-201801-1066",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      }
    ],
    "trust": 2.047222233333333
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:39:52.905000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "VideoXpert Enterprise Video Management System",
        "trust": 0.8,
        "url": "https://www.pelco.com/video-management-system/videoxpert"
      },
      {
        "title": "SchneiderElectricPelcoVideoXpertEnterprise directory traversal vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/111989"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.6,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-355-02"
      },
      {
        "trust": 1.3,
        "url": "https://www.schneider-electric.com/en/download/document/sevd-2017-339-01/"
      },
      {
        "trust": 1.3,
        "url": "http://www.securityfocus.com/bid/102338"
      },
      {
        "trust": 0.9,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9964"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9964"
      },
      {
        "trust": 0.7,
        "url": "https://www.exploit-db.com/exploits/42312/"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/38558"
      },
      {
        "trust": 0.3,
        "url": "https://www.schneider-electric.com/b2b/en/support/cybersecurity/security-notifications.jsp"
      },
      {
        "trust": 0.3,
        "url": "https://download.schneider-electric.com/files?p_endoctype=technical+leaflet\u0026amp;p_file_id=8621588310\u0026amp;p_file_name=sevd-2017-339-01-+pelco+videoxpert+enterprise.pdf\u0026amp;p_reference=sevd-2017-339-01"
      },
      {
        "trust": 0.3,
        "url": "http://securityaffairs.co/wordpress/67108/hacking/pelco-videoxpert-flaws.html"
      },
      {
        "trust": 0.3,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2017122204"
      },
      {
        "trust": 0.3,
        "url": "http://www.isssource.com/schneider-clears-pelco-vulnerabilities/"
      },
      {
        "trust": 0.3,
        "url": "http://www.securityweek.com/schneider-electric-patches-flaws-pelco-video-management-system"
      },
      {
        "trust": 0.3,
        "url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
      },
      {
        "trust": 0.1,
        "url": "http://www.zeroscience.mk/en/vulnerabilities/zsl-2017-5419.php"
      },
      {
        "trust": 0.1,
        "url": "https://cxsecurity.com/issue/wlb-2017070079"
      },
      {
        "trust": 0.1,
        "url": "https://packetstormsecurity.com/files/143318"
      },
      {
        "trust": 0.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/129664"
      },
      {
        "trust": 0.1,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=2017-9964"
      },
      {
        "trust": 0.1,
        "url": "https://www.auscert.org.au/bulletins/56446"
      },
      {
        "trust": 0.1,
        "url": "https://www.exploit-db.com/exploits/42311/"
      },
      {
        "trust": 0.1,
        "url": "https://cxsecurity.com/issue/wlb-2017070077"
      },
      {
        "trust": 0.1,
        "url": "https://packetstormsecurity.com/files/143317"
      },
      {
        "trust": 0.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/129663"
      },
      {
        "trust": 0.1,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=2017-9965"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9965"
      },
      {
        "trust": 0.1,
        "url": "https://www.exploit-db.com/exploits/42310/"
      },
      {
        "trust": 0.1,
        "url": "https://packetstormsecurity.com/files/143316"
      },
      {
        "trust": 0.1,
        "url": "https://cxsecurity.com/issue/wlb-2017070078"
      },
      {
        "trust": 0.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/129662"
      },
      {
        "trust": 0.1,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=2017-9966"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-9966"
      }
    ],
    "sources": [
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "db": "BID",
        "id": "102338"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "db": "BID",
        "id": "102338"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-07-10T00:00:00",
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "date": "2017-07-10T00:00:00",
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "date": "2017-07-10T00:00:00",
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      },
      {
        "date": "2017-08-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "date": "2017-12-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "date": "2017-12-21T00:00:00",
        "db": "BID",
        "id": "102338"
      },
      {
        "date": "2018-01-30T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "date": "2017-06-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      },
      {
        "date": "2018-01-02T03:29:00.267000",
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-01-13T00:00:00",
        "db": "ZSL",
        "id": "ZSL-2017-5420"
      },
      {
        "date": "2018-01-13T00:00:00",
        "db": "ZSL",
        "id": "ZSL-2017-5419"
      },
      {
        "date": "2018-01-13T00:00:00",
        "db": "ZSL",
        "id": "ZSL-2017-5418"
      },
      {
        "date": "2017-08-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-23308"
      },
      {
        "date": "2017-12-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-38302"
      },
      {
        "date": "2017-12-21T00:00:00",
        "db": "BID",
        "id": "102338"
      },
      {
        "date": "2018-01-30T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "date": "2018-01-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      },
      {
        "date": "2024-11-21T03:37:15.877000",
        "db": "NVD",
        "id": "CVE-2017-9964"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Schneider Electric Pelco VideoXpert Enterprise Path traversal vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-011851"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "path traversal",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201706-1084"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.