VAR-201708-1538
Vulnerability from variot - Updated: 2025-04-20 23:23An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device. NOTE: the vendor reports that only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected. ** Unsettled ** This case has not been confirmed as a vulnerability. The vendor has disputed this vulnerability. For details, see NVD of Current Description Please Confirm. https://nvd.nist.gov/vuln/detail/CVE-2017-9856Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SMASolarTechnologyinverter is a photovoltaic inverter device from SMA Germany
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201708-1538",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sunny central storage 720",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 760",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 800",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 500",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 1000",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 2200",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 2500-ev",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 850",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 900",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy storage 2.5",
"scope": "eq",
"trust": 1.6,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 630cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 3600tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny tripower 5000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 3000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 4.0",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 500cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 3.6",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny tripower 25000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny tripower 12000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 2200",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 2.5",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 800cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central storage 630",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny tripower 60",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 5.0",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 720cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 760cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 3.0",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny tripower core1",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 900cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny tripower 20000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 4000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 1.5",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 3600",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 5000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 5000",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 1000cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny central 850cp xt",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny tripower 15000tl",
"scope": "eq",
"trust": 1.0,
"vendor": "sma",
"version": null
},
{
"model": "sunny boy 1.5",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 2.5",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 3.0",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 3.6",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 3000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 3600",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 3600tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 4.0",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 4000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 5.0",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 5000",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy 5000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny boy storage 2.5",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 1000cp xt",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 2200",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 500cp",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 630cp",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 720cp xt",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 760cp xt",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 800cp xt",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 850cp xt",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central 900cp xt",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 1000",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 2200",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 2500-ev",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 500",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 630",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 720",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 760",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 800",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 850",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny central storage 900",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny tripower 12000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny tripower 15000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny tripower 20000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny tripower 25000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny tripower 5000tl",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny tripower 60",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "sunny tripower core1",
"scope": null,
"trust": 0.8,
"vendor": "sma solar",
"version": null
},
{
"model": "solar technology inverter",
"scope": null,
"trust": 0.6,
"vendor": "sma",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-204"
},
{
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_1.5_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_2.5_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_3.0_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_3.6_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_3000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_3600_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_3600tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_4.0_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_4000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_5.0_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_5000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_5000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_boy_storage_2.5_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_1000cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_2200_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_500cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_630cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_720cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_760cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_800cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_850cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_900cp_xt_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_1000_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_2200_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_2500-ev_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_500_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_630_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_720_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_760_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_800_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_850_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_central_storage_900_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_tripower_12000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_tripower_15000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_tripower_20000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_tripower_25000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_tripower_5000tl_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_tripower_60_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:sma_solar_technology_ag:sunny_tripower_core1_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
}
]
},
"cve": "CVE-2017-9856",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2017-9856",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-27847",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-118059",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2017-9856",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "NONE",
"baseScore": 3.4,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.6,
"id": "CVE-2017-9856",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-9856",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2017-9856",
"trust": 1.0,
"value": "LOW"
},
{
"author": "NVD",
"id": "CVE-2017-9856",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2017-27847",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201708-204",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-118059",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"db": "VULHUB",
"id": "VHN-118059"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-204"
},
{
"db": "NVD",
"id": "CVE-2017-9856"
},
{
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are \"encrypted\" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device. NOTE: the vendor reports that only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected. ** Unsettled ** This case has not been confirmed as a vulnerability. The vendor has disputed this vulnerability. For details, see NVD of Current Description Please Confirm. https://nvd.nist.gov/vuln/detail/CVE-2017-9856Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SMASolarTechnologyinverter is a photovoltaic inverter device from SMA Germany",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-9856"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"db": "VULHUB",
"id": "VHN-118059"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-9856",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201708-204",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2017-27847",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-118059",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"db": "VULHUB",
"id": "VHN-118059"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-204"
},
{
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"id": "VAR-201708-1538",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"db": "VULHUB",
"id": "VHN-118059"
}
],
"trust": 1.7
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-27847"
}
]
},
"last_update_date": "2025-04-20T23:23:37.578000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Statement on Cyber Security",
"trust": 0.8,
"url": "https://www.sma.de/en/statement-on-cyber-security.html"
},
{
"title": "WHITEPAPER CYBER SECURITY",
"trust": 0.8,
"url": "https://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1732_07.pdf"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-256",
"trust": 1.0
},
{
"problemtype": "CWE-310",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-118059"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://horusscenario.com/cve-information/"
},
{
"trust": 1.7,
"url": "http://www.sma.de/en/statement-on-cyber-security.html"
},
{
"trust": 1.7,
"url": "http://www.sma.de/fileadmin/content/global/specials/documents/cyber-security/whitepaper-cyber-security-aen1732_07.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9856"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-9856"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"db": "VULHUB",
"id": "VHN-118059"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-204"
},
{
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"db": "VULHUB",
"id": "VHN-118059"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-204"
},
{
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"date": "2017-08-05T00:00:00",
"db": "VULHUB",
"id": "VHN-118059"
},
{
"date": "2017-09-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"date": "2017-08-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-204"
},
{
"date": "2017-08-05T17:29:00.583000",
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-27847"
},
{
"date": "2019-10-03T00:00:00",
"db": "VULHUB",
"id": "VHN-118059"
},
{
"date": "2017-09-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-006908"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-204"
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2017-9856"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201708-204"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural SMA Solar Technology Cryptographic vulnerabilities in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-006908"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "encryption problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201708-204"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.