VAR-201508-0386
Vulnerability from variot - Updated: 2025-04-13 23:39Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. Wonderware System Platform is a system platform applied in multiple fields.
A fixed search path vulnerability exists in Schneider Electric's Wonderware InTouch, Application Server, Historian, and SuiteLink applications. Allows attackers to exploit this vulnerability to install and execute malicious code. Schneider Electric Wonderware System Platform is prone to a local arbitrary-code-execution vulnerability. An attacker can exploit this issue to execute arbitrary code within the context of the affected application or cause the application to crash, resulting in a denial-of-service condition. Wonderware System Platform 2014 R2 and prior are vulnerable. The platform provides visual configuration and deployment, secure data connectivity and communication, data storage and management, and more
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201508-0386",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wonderware system platform 2014",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "r2"
},
{
"model": "wonderware system platform 2014",
"scope": "lt",
"trust": 0.8,
"vendor": "schneider electric",
"version": "r2 patch 01"
},
{
"model": "electric wonderware system platform r2",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "2014"
},
{
"model": "wonderware system platform r2",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "2014"
},
{
"model": "wonderware system platform r2 patch",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "201401"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "BID",
"id": "75297"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
},
{
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:wonderware_system_platform_2014",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ivan Sanchez of WiseSecurity Team",
"sources": [
{
"db": "BID",
"id": "75297"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
}
],
"trust": 0.9
},
"cve": "CVE-2015-3940",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"id": "CVE-2015-3940",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2015-03940",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"id": "VHN-81901",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2015-3940",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2015-3940",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2015-03940",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201507-319",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-81901",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "VULHUB",
"id": "VHN-81901"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
},
{
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. Wonderware System Platform is a system platform applied in multiple fields. \n\nA fixed search path vulnerability exists in Schneider Electric\u0027s Wonderware InTouch, Application Server, Historian, and SuiteLink applications. Allows attackers to exploit this vulnerability to install and execute malicious code. Schneider Electric Wonderware System Platform is prone to a local arbitrary-code-execution vulnerability. \nAn attacker can exploit this issue to execute arbitrary code within the context of the affected application or cause the application to crash, resulting in a denial-of-service condition. \nWonderware System Platform 2014 R2 and prior are vulnerable. The platform provides visual configuration and deployment, secure data connectivity and communication, data storage and management, and more",
"sources": [
{
"db": "NVD",
"id": "CVE-2015-3940"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "BID",
"id": "75297"
},
{
"db": "VULHUB",
"id": "VHN-81901"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSA-15-169-02",
"trust": 3.4
},
{
"db": "NVD",
"id": "CVE-2015-3940",
"trust": 3.4
},
{
"db": "BID",
"id": "75297",
"trust": 2.6
},
{
"db": "SECTRACK",
"id": "1033179",
"trust": 1.1
},
{
"db": "SECTRACK",
"id": "1033180",
"trust": 1.1
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2015-03940",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-81901",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "VULHUB",
"id": "VHN-81901"
},
{
"db": "BID",
"id": "75297"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
},
{
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"id": "VAR-201508-0386",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "VULHUB",
"id": "VHN-81901"
}
],
"trust": 1.40833333
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
}
]
},
"last_update_date": "2025-04-13T23:39:05.781000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "LFSEC00000106",
"trust": 0.8,
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000106/"
},
{
"title": "Patch for Schneider Electric Wonderware System Platform has an unknown vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/60021"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-81901"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-169-02"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/75297"
},
{
"trust": 1.7,
"url": "http://iom.invensys.com/en/pdflibrary/security_bulletin_lfsec00000106.pdf"
},
{
"trust": 1.1,
"url": "http://www.securitytracker.com/id/1033179"
},
{
"trust": 1.1,
"url": "http://www.securitytracker.com/id/1033180"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-3940"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-3940"
},
{
"trust": 0.6,
"url": "https://gcsresource.invensys.com/tracking/confirmdownload.aspx?id=21913"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
},
{
"trust": 0.3,
"url": "http://software.schneider-electric.com/products/wonderware/hmi-and-supervisory-control/system-platform/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "VULHUB",
"id": "VHN-81901"
},
{
"db": "BID",
"id": "75297"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
},
{
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"db": "VULHUB",
"id": "VHN-81901"
},
{
"db": "BID",
"id": "75297"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
},
{
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-06-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"date": "2015-08-04T00:00:00",
"db": "VULHUB",
"id": "VHN-81901"
},
{
"date": "2015-06-19T00:00:00",
"db": "BID",
"id": "75297"
},
{
"date": "2015-08-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"date": "2015-06-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201507-319"
},
{
"date": "2015-08-04T01:59:00.107000",
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-06-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-03940"
},
{
"date": "2016-12-24T00:00:00",
"db": "VULHUB",
"id": "VHN-81901"
},
{
"date": "2015-06-19T00:00:00",
"db": "BID",
"id": "75297"
},
{
"date": "2015-08-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-003986"
},
{
"date": "2015-08-04T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201507-319"
},
{
"date": "2025-04-12T10:46:40.837000",
"db": "NVD",
"id": "CVE-2015-3940"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "75297"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Wonderware System Platform Vulnerability gained in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-003986"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201507-319"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.