VAR-201507-0047
Vulnerability from variot - Updated: 2025-04-13 23:36Siemens SICAM MIC devices with firmware before 2404 allow remote attackers to bypass authentication and obtain administrative access via unspecified HTTP requests. Siemens SICAM MIC is an energy automation modular remote control unit belonging to the SICAM RTU product family. Siemens SICAM MIC is prone to a remote authentication-bypass vulnerability. An attacker can exploit this issue to bypass the authentication mechanism and perform unauthorized actions. This may aid in further attacks. Versions prior to Siemens SICAM MIC 2404 are vulnerable. The equipment is mainly used in the energy industry
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201507-0047",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "sicam mic",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "2403"
},
{
"model": "sicam mic",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "sicam mic",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "v2404"
},
{
"model": "sicam mic",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "2404"
},
{
"model": "sicam mic",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2403"
},
{
"model": "sicam mic",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "sicam mic",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "2404"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "sicam mic",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "BID",
"id": "75904"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-636"
},
{
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/h:siemens:sicam_mic",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:sicam_mic_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Philippe Oechslin from Objectif S\u00e9curit\u00e9",
"sources": [
{
"db": "BID",
"id": "75904"
}
],
"trust": 0.3
},
"cve": "CVE-2015-5386",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CVE-2015-5386",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CNVD-2015-04832",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "822c9e88-2351-11e6-abef-000c29c66e3d",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "VHN-83347",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2015-5386",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2015-5386",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2015-04832",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201507-636",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-83347",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "VULHUB",
"id": "VHN-83347"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-636"
},
{
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SICAM MIC devices with firmware before 2404 allow remote attackers to bypass authentication and obtain administrative access via unspecified HTTP requests. Siemens SICAM MIC is an energy automation modular remote control unit belonging to the SICAM RTU product family. Siemens SICAM MIC is prone to a remote authentication-bypass vulnerability. \nAn attacker can exploit this issue to bypass the authentication mechanism and perform unauthorized actions. This may aid in further attacks. \nVersions prior to Siemens SICAM MIC 2404 are vulnerable. The equipment is mainly used in the energy industry",
"sources": [
{
"db": "NVD",
"id": "CVE-2015-5386"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "BID",
"id": "75904"
},
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-83347"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2015-5386",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-15-195-01",
"trust": 2.8
},
{
"db": "SIEMENS",
"id": "SSA-632547",
"trust": 2.0
},
{
"db": "BID",
"id": "75904",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201507-636",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2015-04832",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846",
"trust": 0.8
},
{
"db": "IVD",
"id": "822C9E88-2351-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-83347",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "VULHUB",
"id": "VHN-83347"
},
{
"db": "BID",
"id": "75904"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-636"
},
{
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"id": "VAR-201507-0047",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "VULHUB",
"id": "VHN-83347"
}
],
"trust": 1.5011904500000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
}
]
},
"last_update_date": "2025-04-13T23:36:27.423000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-632547",
"trust": 0.8,
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-632547.pdf"
},
{
"title": "Siemens SICAM MIC authentication bypass vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/61281"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-83347"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-195-01"
},
{
"trust": 2.0,
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-632547.pdf"
},
{
"trust": 1.4,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-5386"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-5386"
},
{
"trust": 0.3,
"url": "http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/substation-automation/remote-terminal-units/pages/sicam-mic.aspx"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "VULHUB",
"id": "VHN-83347"
},
{
"db": "BID",
"id": "75904"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-636"
},
{
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"db": "VULHUB",
"id": "VHN-83347"
},
{
"db": "BID",
"id": "75904"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-636"
},
{
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-07-27T00:00:00",
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"date": "2015-07-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"date": "2015-07-16T00:00:00",
"db": "VULHUB",
"id": "VHN-83347"
},
{
"date": "2015-07-15T00:00:00",
"db": "BID",
"id": "75904"
},
{
"date": "2015-07-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"date": "2015-07-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201507-636"
},
{
"date": "2015-07-16T19:59:04.660000",
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-07-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-04832"
},
{
"date": "2015-07-17T00:00:00",
"db": "VULHUB",
"id": "VHN-83347"
},
{
"date": "2015-07-15T00:00:00",
"db": "BID",
"id": "75904"
},
{
"date": "2015-07-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-003846"
},
{
"date": "2015-07-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201507-636"
},
{
"date": "2025-04-12T10:46:40.837000",
"db": "NVD",
"id": "CVE-2015-5386"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201507-636"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SICAM MIC Authentication Bypass Vulnerability",
"sources": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04832"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation",
"sources": [
{
"db": "IVD",
"id": "822c9e88-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-636"
}
],
"trust": 0.8
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.