Vulnerability from variot - Updated: 2025-04-13 23:02A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. Siemens SIPROTEC 4 and SIPROTEC Compact Device EN100 Module firmware has a service disruption (DoS) There are vulnerabilities that are put into a state. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. http://cwe.mitre.org/data/definitions/19.htmlBy a third party UDP port 50000 Denial of service via the above crafted packets (DoS) There is a possibility of being put into a state. The SIPROTEC 4 and SIPROTEC devices offer a wide range of integrated protection, control, measurement and power substation automation functions; the EN100 module is used for IEC 61850 communication. The EN100 module for multiple Siemens SIPROTEC products are prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device. EN100 is one of the multi-format encoder modules
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201507-0039",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "siprotec",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "4.24"
},
{
"model": "siprotec 4",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "siprotec compact",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "siprotec",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "4.25"
},
{
"model": "siprotec",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v4.24"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "siprotec",
"version": "4.24"
},
{
"model": "siprotec compact",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "siprotec 7ut686",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "siprotec 7sj686",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "siprotec 7sj66",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "siprotec 7sd686",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "siprotec",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "40"
},
{
"model": "profinet io",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "modbus tcp",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "iec",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "1040"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.9"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.8"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.7"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.6"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.5"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.4"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.3"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.24"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.23"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.22"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.21"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.20"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.2"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.19"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.18"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.17"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.16"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.15"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.14"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.13"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.12"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.11"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.10"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.1"
},
{
"model": "en100",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4.0"
},
{
"model": "dnp3 tcp",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "profinet io",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "1.4.1"
},
{
"model": "en100",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "4.25"
}
],
"sources": [
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "BID",
"id": "75948"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
},
{
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/h:siemens:siprotec_4",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:siprotec_compact",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:siprotec_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "M. Can Kurnaz",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
}
],
"trust": 0.6
},
"cve": "CVE-2015-5374",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2015-5374",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2015-04733",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-83335",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2015-5374",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2015-5374",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2015-04733",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201507-644",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-83335",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2015-5374",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "VULHUB",
"id": "VHN-83335"
},
{
"db": "VULMON",
"id": "CVE-2015-5374"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
},
{
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. Siemens SIPROTEC 4 and SIPROTEC Compact Device EN100 Module firmware has a service disruption (DoS) There are vulnerabilities that are put into a state. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. http://cwe.mitre.org/data/definitions/19.htmlBy a third party UDP port 50000 Denial of service via the above crafted packets (DoS) There is a possibility of being put into a state. The SIPROTEC 4 and SIPROTEC devices offer a wide range of integrated protection, control, measurement and power substation automation functions; the EN100 module is used for IEC 61850 communication. The EN100 module for multiple Siemens SIPROTEC products are prone to a denial-of-service vulnerability. \nRemote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device. EN100 is one of the multi-format encoder modules",
"sources": [
{
"db": "NVD",
"id": "CVE-2015-5374"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "BID",
"id": "75948"
},
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-83335"
},
{
"db": "VULMON",
"id": "CVE-2015-5374"
}
],
"trust": 2.97
},
"exploit_availability": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"reference": "https://www.scap.org.cn/vuln/vhn-83335",
"trust": 0.1,
"type": "unknown"
},
{
"reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=44103",
"trust": 0.1,
"type": "exploit"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-83335"
},
{
"db": "VULMON",
"id": "CVE-2015-5374"
}
]
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2015-5374",
"trust": 3.9
},
{
"db": "ICS CERT",
"id": "ICSA-17-187-03",
"trust": 2.3
},
{
"db": "ICS CERT",
"id": "ICSA-15-202-01",
"trust": 2.3
},
{
"db": "SIEMENS",
"id": "SSA-732541",
"trust": 2.1
},
{
"db": "BID",
"id": "75948",
"trust": 2.1
},
{
"db": "EXPLOIT-DB",
"id": "44103",
"trust": 1.2
},
{
"db": "SIEMENS",
"id": "SSA-323211",
"trust": 1.2
},
{
"db": "CNNVD",
"id": "CNNVD-201507-644",
"trust": 1.1
},
{
"db": "CNVD",
"id": "CNVD-2015-04733",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890",
"trust": 0.8
},
{
"db": "CXSECURITY",
"id": "WLB-2018020218",
"trust": 0.6
},
{
"db": "IVD",
"id": "78FDECC2-A9AF-4A66-B218-01A620B751D5",
"trust": 0.2
},
{
"db": "IVD",
"id": "820A6B4C-2351-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "PACKETSTORM",
"id": "146427",
"trust": 0.1
},
{
"db": "SEEBUG",
"id": "SSVID-89506",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-83335",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2015-5374",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "VULHUB",
"id": "VHN-83335"
},
{
"db": "VULMON",
"id": "CVE-2015-5374"
},
{
"db": "BID",
"id": "75948"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
},
{
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"id": "VAR-201507-0039",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "VULHUB",
"id": "VHN-83335"
}
],
"trust": 1.6782828066666666
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.4
}
],
"sources": [
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
}
]
},
"last_update_date": "2025-04-13T23:02:43.818000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-73254",
"trust": 0.8,
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf"
},
{
"title": "SIPROTEC 4 denial of service vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/61054"
},
{
"title": "Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Fixes for module denial of service vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=160157"
},
{
"title": "The Register",
"trust": 0.2,
"url": "https://www.theregister.co.uk/2017/06/12/industroyer_malware/"
},
{
"title": "IDPS",
"trust": 0.1,
"url": "https://github.com/g4xyk00/IDPS "
},
{
"title": "CVE-2015-5374-DoS-PoC",
"trust": 0.1,
"url": "https://github.com/can/CVE-2015-5374-DoS-PoC "
},
{
"title": "",
"trust": 0.1,
"url": "https://github.com/khulnasoft-labs/awesome-security "
},
{
"title": "welivesecurity",
"trust": 0.1,
"url": "https://www.welivesecurity.com/2017/06/12/industroyer-biggest-threat-industrial-control-systems-since-stuxnet/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "VULMON",
"id": "CVE-2015-5374"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-19",
"trust": 1.1
},
{
"problemtype": "CWE-Other",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-83335"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-202-01"
},
{
"trust": 2.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-187-03"
},
{
"trust": 2.1,
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf"
},
{
"trust": 1.3,
"url": "https://www.exploit-db.com/exploits/44103/"
},
{
"trust": 1.2,
"url": "http://www.securityfocus.com/bid/75948"
},
{
"trust": 1.2,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-323211.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-5374"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-5374"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/issue/wlb-2018020218"
},
{
"trust": 0.3,
"url": "http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/protection/siprotec4/pages/overview.aspx"
},
{
"trust": 0.3,
"url": "http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/protection/siprotec-compact/pages/overview.aspx"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/19.html"
},
{
"trust": 0.1,
"url": "https://github.com/g4xyk00/idps"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "http://tools.cisco.com/security/center/viewalert.x?alertid=40100"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "VULHUB",
"id": "VHN-83335"
},
{
"db": "VULMON",
"id": "CVE-2015-5374"
},
{
"db": "BID",
"id": "75948"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
},
{
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"db": "VULHUB",
"id": "VHN-83335"
},
{
"db": "VULMON",
"id": "CVE-2015-5374"
},
{
"db": "BID",
"id": "75948"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
},
{
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-07-23T00:00:00",
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"date": "2015-07-23T00:00:00",
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"date": "2015-07-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"date": "2015-07-18T00:00:00",
"db": "VULHUB",
"id": "VHN-83335"
},
{
"date": "2015-07-18T00:00:00",
"db": "VULMON",
"id": "CVE-2015-5374"
},
{
"date": "2015-07-17T00:00:00",
"db": "BID",
"id": "75948"
},
{
"date": "2015-07-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"date": "2015-07-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201507-644"
},
{
"date": "2015-07-18T10:59:04.117000",
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-07-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-04733"
},
{
"date": "2018-03-23T00:00:00",
"db": "VULHUB",
"id": "VHN-83335"
},
{
"date": "2018-03-23T00:00:00",
"db": "VULMON",
"id": "CVE-2015-5374"
},
{
"date": "2017-07-11T12:06:00",
"db": "BID",
"id": "75948"
},
{
"date": "2017-09-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-003890"
},
{
"date": "2021-08-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201507-644"
},
{
"date": "2025-04-12T10:46:40.837000",
"db": "NVD",
"id": "CVE-2015-5374"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIPROTEC 4 Denial of service vulnerability",
"sources": [
{
"db": "IVD",
"id": "78fdecc2-a9af-4a66-b218-01a620b751d5"
},
{
"db": "IVD",
"id": "820a6b4c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-04733"
}
],
"trust": 1.0
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201507-644"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.