VAR-201506-0115

Vulnerability from variot - Updated: 2025-04-13 23:37

The management web interface in Alcatel-Lucent OmniSwitch 6450, 6250, 6850E, 9000E, 6400, and 6855 with firmware before 6.6.4.309.R01 and 6.6.5.x before 6.6.5.80.R02 generates weak session identifiers, which allows remote attackers to hijack arbitrary sessions via a brute force attack. The Alcatel-Lucent OmniSwitch 6450 is a switch product developed by Alcatel-Lucent, France. Multiple Alcatel-Lucent OmniSwitch products are prone to a session-fixation vulnerability. An attacker can exploit this issue to hijack an arbitrary session or gain access to the sensitive information. This may aid in further attacks. Alcatel-Lucent OmniSwitch 6450, etc. The following products and versions are affected: Alcatel-Lucent OmniSwitch 6450, 6250, 6850E, 9000E, 6400, 6855 using firmware versions prior to 6.6.4.309.R01 and 6.6.5.x prior to 6.6.5.80.R02

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201506-0115",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "omniswitch",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "alcatel lucent",
        "version": "6.6.5.r02"
      },
      {
        "model": "omniswitch",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "alcatel lucent",
        "version": "6.6.4.r01"
      },
      {
        "model": "omniswitch",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "alcatel lucent",
        "version": "6.4.5.r02"
      },
      {
        "model": "omniswitch",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "alcatel lucent",
        "version": "6.4.6.r01"
      },
      {
        "model": "omniswitch 6400",
        "scope": null,
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6250",
        "scope": null,
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6850e",
        "scope": null,
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": "6.6.5.x"
      },
      {
        "model": "omniswitch 6450",
        "scope": null,
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 9000e",
        "scope": null,
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": "6.6.5.80.r02"
      },
      {
        "model": "omniswitch 6855",
        "scope": null,
        "trust": 0.8,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6.4.5.r02;6.4.6.r01;6.6.4.r01;6.6.5.r02",
        "scope": null,
        "trust": 0.6,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "alcatel lucent",
        "version": "6.4.6.r01"
      },
      {
        "model": "omniswitch",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "alcatel lucent",
        "version": "6.4.5.r02"
      },
      {
        "model": "omniswitch",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "alcatel lucent",
        "version": "6.6.4.r01"
      },
      {
        "model": "omniswitch",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "alcatel lucent",
        "version": "6.6.5.r02"
      },
      {
        "model": "omniswitch 9000e 6.6.5.r02",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 9000e 6.6.4.r01",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 9000e 6.4.6.r01",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 9000e 6.4.5.r02",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6.6.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6855"
      },
      {
        "model": "omniswitch 6.6.4.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6855"
      },
      {
        "model": "omniswitch 6.4.6.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6855"
      },
      {
        "model": "omniswitch 6.4.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6855"
      },
      {
        "model": "omniswitch 6850e 6.6.5.r02",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6850e 6.6.4.r01",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6850e 6.4.6.r01",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6850e 6.4.5.r02",
        "scope": null,
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6.6.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6450"
      },
      {
        "model": "omniswitch 6.6.4.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6450"
      },
      {
        "model": "omniswitch 6.4.6.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6450"
      },
      {
        "model": "omniswitch 6.4.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6450"
      },
      {
        "model": "omniswitch 6.6.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6400"
      },
      {
        "model": "omniswitch 6.6.4.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6400"
      },
      {
        "model": "omniswitch 6.4.6.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6400"
      },
      {
        "model": "omniswitch 6.4.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6400"
      },
      {
        "model": "omniswitch 6.6.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6250"
      },
      {
        "model": "omniswitch 6.6.4.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6250"
      },
      {
        "model": "omniswitch 6.4.6.r01",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6250"
      },
      {
        "model": "omniswitch 6.4.5.r02",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6250"
      },
      {
        "model": "omniswitch 9000e 6.6.5.80.r02",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 9000e 6.6.4.309.r01",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6.6.5.80.r02",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6855"
      },
      {
        "model": "omniswitch 6.6.4.309.r01",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6855"
      },
      {
        "model": "omniswitch 6850e 6.6.5.80.r02",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6850e 6.6.4.309.r01",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": null
      },
      {
        "model": "omniswitch 6.6.5.80.r02",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6450"
      },
      {
        "model": "omniswitch 6.6.4.309.r01",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6450"
      },
      {
        "model": "omniswitch 6.6.5.80.r02",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6400"
      },
      {
        "model": "omniswitch 6.6.4.309.r01",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6400"
      },
      {
        "model": "omniswitch 6.6.5.80.r02",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6250"
      },
      {
        "model": "omniswitch 6.6.4.309.r01",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "alcatel lucent",
        "version": "6250"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "BID",
        "id": "75125"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/h:alcatel-lucent:omniswitch_6250",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:alcatel-lucent:omniswitch_6400",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:alcatel-lucent:omniswitch_6450",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:alcatel-lucent:omniswitch_6850e",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:alcatel-lucent:omniswitch_6855",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:alcatel-lucent:omniswitch_9000e",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:alcatel-lucent:omniswitch_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "RedTeam Pentesting GmbH",
    "sources": [
      {
        "db": "BID",
        "id": "75125"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2015-2804",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2015-2804",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2015-03897",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "VHN-80765",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2015-2804",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2015-2804",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2015-03897",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201506-296",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-80765",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The management web interface in Alcatel-Lucent OmniSwitch 6450, 6250, 6850E, 9000E, 6400, and 6855 with firmware before 6.6.4.309.R01 and 6.6.5.x before 6.6.5.80.R02 generates weak session identifiers, which allows remote attackers to hijack arbitrary sessions via a brute force attack. The Alcatel-Lucent OmniSwitch 6450 is a switch product developed by Alcatel-Lucent, France. Multiple Alcatel-Lucent OmniSwitch products are prone to a session-fixation vulnerability. \nAn attacker can exploit this issue to hijack an arbitrary session or gain access to the sensitive information. This may aid in further attacks. Alcatel-Lucent OmniSwitch 6450, etc. The following products and versions are affected: Alcatel-Lucent OmniSwitch 6450, 6250, 6850E, 9000E, 6400, 6855 using firmware versions prior to 6.6.4.309.R01 and 6.6.5.x prior to 6.6.5.80.R02",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-2804"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "BID",
        "id": "75125"
      },
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      }
    ],
    "trust": 2.52
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-80765",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2015-2804",
        "trust": 3.4
      },
      {
        "db": "BID",
        "id": "75125",
        "trust": 2.0
      },
      {
        "db": "PACKETSTORM",
        "id": "132235",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-80765",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      },
      {
        "db": "BID",
        "id": "75125"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "id": "VAR-201506-0115",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      }
    ],
    "trust": 1.7
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      }
    ]
  },
  "last_update_date": "2025-04-13T23:37:32.195000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.alcatel-lucent.com/"
      },
      {
        "title": "Patches for multiple Alcatel-Lucent OmniSwitch product session hijacking vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/59879"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-200",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.8,
        "url": "https://www.redteam-pentesting.de/en/advisories/rt-sa-2015-003/-alcatel-lucent-omniswitch-web-interface-weak-session-id"
      },
      {
        "trust": 1.7,
        "url": "http://seclists.org/fulldisclosure/2015/jun/22"
      },
      {
        "trust": 1.7,
        "url": "http://packetstormsecurity.com/files/132235/alcatel-lucent-omniswitch-web-interface-weak-session-id.html"
      },
      {
        "trust": 1.2,
        "url": "http://www.securityfocus.com/archive/1/archive/1/535731/100/0/threaded"
      },
      {
        "trust": 1.1,
        "url": "http://www.securityfocus.com/bid/75125"
      },
      {
        "trust": 1.1,
        "url": "http://www.securityfocus.com/archive/1/535731/100/0/threaded"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-2804"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-2804"
      },
      {
        "trust": 0.3,
        "url": "http://www.alcatel-lucent.com/"
      },
      {
        "trust": 0.3,
        "url": "http://enterprise.alcatel-lucent.com/?product=omniswitch6450\u0026page=overview"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      },
      {
        "db": "BID",
        "id": "75125"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "db": "VULHUB",
        "id": "VHN-80765"
      },
      {
        "db": "BID",
        "id": "75125"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-06-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "date": "2015-06-16T00:00:00",
        "db": "VULHUB",
        "id": "VHN-80765"
      },
      {
        "date": "2015-06-10T00:00:00",
        "db": "BID",
        "id": "75125"
      },
      {
        "date": "2015-06-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "date": "2015-06-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      },
      {
        "date": "2015-06-16T16:59:00.067000",
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-06-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-03897"
      },
      {
        "date": "2018-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-80765"
      },
      {
        "date": "2015-06-10T00:00:00",
        "db": "BID",
        "id": "75125"
      },
      {
        "date": "2015-06-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      },
      {
        "date": "2015-06-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      },
      {
        "date": "2025-04-12T10:46:40.837000",
        "db": "NVD",
        "id": "CVE-2015-2804"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Alcatel-Lucent OmniSwitch Firmware management  Web Vulnerability in session hijacking session",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-003166"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "information disclosure",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201506-296"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…