VAR-201504-0235
Vulnerability from variot - Updated: 2025-04-13 23:09Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. plural SIMATIC HMI Products and SIMATIC WinCC Contains a vulnerability that allows authentication to be completed.Even if there is no related password information, a third party may use the password hash to complete the authentication. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. Siemens SIMATIC and SIMATIC WinCC HMI Comfort Panels have verification bypass vulnerabilities that allow remote attackers to exploit vulnerabilities to bypass authentication. Multiple Siemens SIMATIC products are prone to an authentication-bypass vulnerability. This may aid in further attacks. The SIMATIC HMI Panel series, SIMATIC WinCC Runtime Advanced and Professional are all HMI software for operating and monitoring machines and plants. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A remote attacker could exploit this vulnerability to authenticate using a known hashed password
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201504-0235",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 2.2,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 2.2,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "wincc",
"scope": "eq",
"trust": 2.2,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "wincc",
"scope": "eq",
"trust": 2.2,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "13.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "*"
},
{
"model": "simatic hmi basic panels 2nd generation",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "(wincc 13 sp1 upd2"
},
{
"model": "simatic hmi mobile panel 277",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "(wincc all versions )"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7.3 upd4"
},
{
"model": "simatic hmi comfort panels",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": ")"
},
{
"model": "simatic hmi multi panels",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "(wincc all versions )"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "(wincc 13 sp1 upd2"
},
{
"model": "simatic hmi basic panels 1st generation",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "(wincc all versions )"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic hmi basic panels 2nd generation",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": ")"
},
{
"model": "simatic hmi basic panels generation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "1"
},
{
"model": "simatic hmi basic panels generation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2"
},
{
"model": "simatic hmi comfort panels",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi mobile panel",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "277"
},
{
"model": "simatic hmi mobile panels",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "13.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.3"
}
],
"sources": [
{
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"db": "CNNVD",
"id": "CNNVD-201504-097"
},
{
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/h:siemens:simatic_hmi_basic_panels_generation_1",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:simatic_hmi_basic_panels_generation_2",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:simatic_hmi_comfort_panels",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:simatic_hmi_mobile_panel_277",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/h:siemens:simatic_hmi_multi_panels",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Quarkslab team and Ilya Karpov from Positive Technologies.",
"sources": [
{
"db": "BID",
"id": "74040"
}
],
"trust": 0.3
},
"cve": "CVE-2015-2823",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2015-2823",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.9,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2015-02291",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "9844de6a-2351-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-80784",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2015-2823",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2015-2823",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2015-02291",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201504-097",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-80784",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2015-2823",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "VULHUB",
"id": "VHN-80784"
},
{
"db": "VULMON",
"id": "CVE-2015-2823"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"db": "CNNVD",
"id": "CNNVD-201504-097"
},
{
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. plural SIMATIC HMI Products and SIMATIC WinCC Contains a vulnerability that allows authentication to be completed.Even if there is no related password information, a third party may use the password hash to complete the authentication. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. Siemens SIMATIC and SIMATIC WinCC HMI Comfort Panels have verification bypass vulnerabilities that allow remote attackers to exploit vulnerabilities to bypass authentication. Multiple Siemens SIMATIC products are prone to an authentication-bypass vulnerability. This may aid in further attacks. The SIMATIC HMI Panel series, SIMATIC WinCC Runtime Advanced and Professional are all HMI software for operating and monitoring machines and plants. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A remote attacker could exploit this vulnerability to authenticate using a known hashed password",
"sources": [
{
"db": "NVD",
"id": "CVE-2015-2823"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "BID",
"id": "74040"
},
{
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-80784"
},
{
"db": "VULMON",
"id": "CVE-2015-2823"
}
],
"trust": 2.97
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2015-2823",
"trust": 3.9
},
{
"db": "BID",
"id": "74040",
"trust": 2.1
},
{
"db": "SIEMENS",
"id": "SSA-487246",
"trust": 1.8
},
{
"db": "CNNVD",
"id": "CNNVD-201504-097",
"trust": 1.1
},
{
"db": "CNVD",
"id": "CNVD-2015-02291",
"trust": 1.0
},
{
"db": "ICS CERT",
"id": "ICSA-15-099-01",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126",
"trust": 0.8
},
{
"db": "IVD",
"id": "344280CB-0461-40FA-A3C6-537FF0CE4AFF",
"trust": 0.2
},
{
"db": "IVD",
"id": "9844DE6A-2351-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-80784",
"trust": 0.1
},
{
"db": "ICS CERT",
"id": "ICSA-15-099-01E",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2015-2823",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "VULHUB",
"id": "VHN-80784"
},
{
"db": "VULMON",
"id": "CVE-2015-2823"
},
{
"db": "BID",
"id": "74040"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"db": "CNNVD",
"id": "CNNVD-201504-097"
},
{
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"id": "VAR-201504-0235",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "VULHUB",
"id": "VHN-80784"
}
],
"trust": 1.8226849
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 1.0
}
],
"sources": [
{
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-02291"
}
]
},
"last_update_date": "2025-04-13T23:09:55.643000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-487246",
"trust": 0.8,
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf"
},
{
"title": "Siemens SIMATIC and SIMATIC WinCC HMI Comfort Panels verify patches for bypassing vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/57127"
},
{
"title": "The Register",
"trust": 0.2,
"url": "https://www.theregister.co.uk/2015/08/31/ruskie_ics_hacker_drops_nine_holes_in_popular_siemens_power_plant_kit/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "VULMON",
"id": "CVE-2015-2823"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-80784"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf"
},
{
"trust": 1.4,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-2823"
},
{
"trust": 1.3,
"url": "http://www.securityfocus.com/bid/74040"
},
{
"trust": 1.2,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-2823"
},
{
"trust": 0.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-099-01"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/287.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.theregister.co.uk/2015/08/31/ruskie_ics_hacker_drops_nine_holes_in_popular_siemens_power_plant_kit/"
},
{
"trust": 0.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-15-099-01e"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "VULHUB",
"id": "VHN-80784"
},
{
"db": "VULMON",
"id": "CVE-2015-2823"
},
{
"db": "BID",
"id": "74040"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"db": "CNNVD",
"id": "CNNVD-201504-097"
},
{
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"db": "VULHUB",
"id": "VHN-80784"
},
{
"db": "VULMON",
"id": "CVE-2015-2823"
},
{
"db": "BID",
"id": "74040"
},
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"db": "CNNVD",
"id": "CNNVD-201504-097"
},
{
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-04-10T00:00:00",
"db": "IVD",
"id": "344280cb-0461-40fa-a3c6-537ff0ce4aff"
},
{
"date": "2015-04-10T00:00:00",
"db": "IVD",
"id": "9844de6a-2351-11e6-abef-000c29c66e3d"
},
{
"date": "2015-04-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"date": "2015-04-08T00:00:00",
"db": "VULHUB",
"id": "VHN-80784"
},
{
"date": "2015-04-08T00:00:00",
"db": "VULMON",
"id": "CVE-2015-2823"
},
{
"date": "2015-04-10T00:00:00",
"db": "BID",
"id": "74040"
},
{
"date": "2015-04-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"date": "2015-04-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201504-097"
},
{
"date": "2015-04-08T16:59:01.270000",
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-04-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2015-02291"
},
{
"date": "2016-11-28T00:00:00",
"db": "VULHUB",
"id": "VHN-80784"
},
{
"date": "2016-11-28T00:00:00",
"db": "VULMON",
"id": "CVE-2015-2823"
},
{
"date": "2015-11-03T19:21:00",
"db": "BID",
"id": "74040"
},
{
"date": "2015-04-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2015-002126"
},
{
"date": "2015-04-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201504-097"
},
{
"date": "2025-04-12T10:46:40.837000",
"db": "NVD",
"id": "CVE-2015-2823"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201504-097"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural SIMATIC HMI Products and SIMATIC WinCC Vulnerabilities that complete authentication",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2015-002126"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201504-097"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.