VAR-201310-0198

Vulnerability from variot - Updated: 2025-04-11 23:16

Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000. Xper is a physiological testing system that is mostly deployed in the medical and public health sectors. Xper Connect is prone to a heap-based buffer-overflow vulnerability because the application fails to perform adequate boundary checks on user-supplied input. Attackers may leverage this issue to execute arbitrary code in the context of the application. Failed attacks will cause denial-of-service conditions. Versions prior to Xper Connect 1.5.4.053 SP2 is vulnerable. Philips Xper Information Management Physiomonitoring, etc. are all components in the healthcare information system (Xper Cardiovascular Workflow Solution) of Philips, the Netherlands. The solution provides workflow charting, registry management, real-time hemodynamic monitoring and reporting, and more. A heap-based buffer overflow vulnerability exists in the Philips Xper application

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201310-0198",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "xper information management physiomonitoring 5",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "philips",
        "version": null
      },
      {
        "model": "xper information management vascular monitoring 5",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "philips",
        "version": null
      },
      {
        "model": "xper flex cardio",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "philips",
        "version": null
      },
      {
        "model": "xperconnect",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "philips",
        "version": "1.5.4.053"
      },
      {
        "model": "xper connect",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "philips",
        "version": "1.5.4.053 sp2"
      },
      {
        "model": "xper flex cardio",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "philips",
        "version": "product  xper information management server and work station"
      },
      {
        "model": "xper information management physiomonitoring 5",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "philips",
        "version": "component"
      },
      {
        "model": "xper information management vascular monitoring 5",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "philips",
        "version": "component"
      },
      {
        "model": "philips n.v. xper connect",
        "scope": null,
        "trust": 0.6,
        "vendor": "koninklijke",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:philips:xperconnect",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:philips:xper_flex_cardio",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:philips:xper_information_management_physiomonitoring_5",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:philips:xper_information_management_vascular_monitoring_5",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Billy Rios",
    "sources": [
      {
        "db": "BID",
        "id": "62845"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2013-2808",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2013-2808",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2013-13488",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "VHN-62810",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2013-2808",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2013-2808",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2013-13488",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201310-020",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-62810",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "db": "VULHUB",
        "id": "VHN-62810"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000. Xper is a physiological testing system that is mostly deployed in the medical and public health sectors. Xper Connect is prone to a heap-based buffer-overflow vulnerability because the application fails to perform adequate boundary checks on user-supplied input. \nAttackers may leverage this issue to execute arbitrary code in the context of the application. Failed attacks will cause denial-of-service conditions. \nVersions prior to Xper Connect 1.5.4.053 SP2 is vulnerable. Philips Xper Information Management Physiomonitoring, etc. are all components in the healthcare information system (Xper Cardiovascular Workflow Solution) of Philips, the Netherlands. The solution provides workflow charting, registry management, real-time hemodynamic monitoring and reporting, and more. A heap-based buffer overflow vulnerability exists in the Philips Xper application",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2013-2808"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "db": "BID",
        "id": "62845"
      },
      {
        "db": "VULHUB",
        "id": "VHN-62810"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2013-2808",
        "trust": 3.4
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-13-277-01",
        "trust": 3.1
      },
      {
        "db": "BID",
        "id": "62845",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-62810",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "db": "VULHUB",
        "id": "VHN-62810"
      },
      {
        "db": "BID",
        "id": "62845"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "id": "VAR-201310-0198",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-62810"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2025-04-11T23:16:36.674000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Xper Flex Cardio Physiomonitoring System",
        "trust": 0.8,
        "url": "http://www.healthcare.philips.com/main/products/cath_lab_exp/xper_info_mgt/flex_cardio_physiomonitoring.wpd"
      },
      {
        "title": "Xper Physiomonitoring 5",
        "trust": 0.8,
        "url": "http://www.healthcare.philips.com/main/products/cath_lab_exp/xper_info_mgt/"
      },
      {
        "title": "Xper Connect",
        "trust": 0.8,
        "url": "http://www.healthcare.philips.com/us_en/products/cath_lab_exp/xper_info_mgt/connect.wpd"
      },
      {
        "title": "Xper Vascular Monitoring 5",
        "trust": 0.8,
        "url": "http://www.healthcare.philips.com/us_en/products/cath_lab_exp/xper_info_mgt/vascular_monitoring.wpd"
      },
      {
        "title": "Patch for Xper Connect Remote Heap Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/40000"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-62810"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "http://ics-cert.us-cert.gov/advisories/icsa-13-277-01"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-2808"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-2808"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "db": "VULHUB",
        "id": "VHN-62810"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "db": "VULHUB",
        "id": "VHN-62810"
      },
      {
        "db": "BID",
        "id": "62845"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2013-10-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "date": "2013-10-05T00:00:00",
        "db": "VULHUB",
        "id": "VHN-62810"
      },
      {
        "date": "2013-10-04T00:00:00",
        "db": "BID",
        "id": "62845"
      },
      {
        "date": "2013-10-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "date": "2013-10-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      },
      {
        "date": "2013-10-05T10:55:03.463000",
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2013-10-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2013-13488"
      },
      {
        "date": "2013-10-07T00:00:00",
        "db": "VULHUB",
        "id": "VHN-62810"
      },
      {
        "date": "2013-10-04T00:00:00",
        "db": "BID",
        "id": "62845"
      },
      {
        "date": "2013-10-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      },
      {
        "date": "2013-10-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2013-2808"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Philips Product  Xper Connect Heap-based buffer overflow vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-004509"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer overflow",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201310-020"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour