VAR-201306-0314

Vulnerability from variot - Updated: 2025-04-11 22:59

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. By operating the database, remote attackers can exploit this vulnerability to enhance their permissions. Depending on the system configuration, it is possible to obtain full system access rights and execute. Any SQL command

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201306-0314",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic pcs7",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "8.0"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "7.1"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "7.0"
      },
      {
        "model": "simatic pcs7",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "8.0"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.2"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.8,
        "vendor": "wincc",
        "version": "7.0"
      },
      {
        "model": "simatic pcs 7",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "8.0 sp1"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "7.2 update 1"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "7.x"
      },
      {
        "model": "simatic pcs",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "78.x"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "7.2"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "7.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic pcs7",
        "version": "8.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic pcs7",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_pcs_7",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Alexander Tlyapov from Positive Technologies",
    "sources": [
      {
        "db": "BID",
        "id": "60558"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2013-3957",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2013-3957",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2013-07609",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e6a420b0-2352-11e6-abef-000c29c66e3d",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-63959",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2013-3957",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2013-3957",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2013-07609",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201306-247",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e6a420b0-2352-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-63959",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "VULHUB",
        "id": "VHN-63959"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. By operating the database, remote attackers can exploit this vulnerability to enhance their permissions. Depending on the system configuration, it is possible to obtain full system access rights and execute. Any SQL command",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2013-3957"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "BID",
        "id": "60558"
      },
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-63959"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2013-3957",
        "trust": 3.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345843",
        "trust": 1.7
      },
      {
        "db": "SECUNIA",
        "id": "53805",
        "trust": 1.2
      },
      {
        "db": "BID",
        "id": "60558",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "E6A420B0-2352-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-63959",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "VULHUB",
        "id": "VHN-63959"
      },
      {
        "db": "BID",
        "id": "60558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "id": "VAR-201306-0314",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "VULHUB",
        "id": "VHN-63959"
      }
    ],
    "trust": 1.5048571666666666
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:59:07.270000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345843: Vulnerabilites in WinCC 7.2",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC/PCS 7 SQL Injection Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/34669"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-89",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-63959"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-3957"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-3957"
      },
      {
        "trust": 0.6,
        "url": "http://secunia.com/advisories/53805/"
      },
      {
        "trust": 0.6,
        "url": "http://secunia.com/advisories/53805"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "VULHUB",
        "id": "VHN-63959"
      },
      {
        "db": "BID",
        "id": "60558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "db": "VULHUB",
        "id": "VHN-63959"
      },
      {
        "db": "BID",
        "id": "60558"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      },
      {
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2013-06-19T00:00:00",
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2013-06-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "date": "2013-06-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-63959"
      },
      {
        "date": "2013-06-14T00:00:00",
        "db": "BID",
        "id": "60558"
      },
      {
        "date": "2013-06-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "date": "2013-06-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      },
      {
        "date": "2013-06-14T19:55:01.233000",
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2013-06-19T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2013-07609"
      },
      {
        "date": "2013-06-17T00:00:00",
        "db": "VULHUB",
        "id": "VHN-63959"
      },
      {
        "date": "2015-03-19T08:17:00",
        "db": "BID",
        "id": "60558"
      },
      {
        "date": "2013-06-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      },
      {
        "date": "2013-07-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2013-3957"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SIMATIC PCS 7 Used in  Siemens WinCC of  Web Navigator In  SQL Injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2013-002982"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SQL injection",
    "sources": [
      {
        "db": "IVD",
        "id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201306-247"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…