VAR-201207-0169
Vulnerability from variot - Updated: 2025-04-11 23:09The web interface on the SMC SMC8024L2 switch allows remote attackers to bypass authentication and obtain administrative access via a direct request to a .html file under (1) status/, (2) system/, (3) ports/, (4) trunks/, (5) vlans/, (6) qos/, (7) rstp/, (8) dot1x/, (9) security/, (10) igmps/, or (11) snmp/. SMC8024L2 There is an authentication bypass vulnerability in the web management screen. SMC Networks Inc. Network switch provided by SMC8024L2 There is an authentication bypass vulnerability in the web management screen. In the web interface URL By directly entering, you can access without requiring authentication.A remote attacker may change the settings of the product. The SMC Networks SMC8024L2 Switch is a powerful switch. The WEB interface of the SMC Networks SMC8024L2 switch incorrectly restricts user access. The SMC8024L2 is a multifunctional 10/100/1000BASE-T independently managed switch
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201207-0169",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smc8024l2 switch",
"scope": null,
"trust": 1.2,
"vendor": "smc",
"version": null
},
{
"model": "smc8024l2 switch",
"scope": "eq",
"trust": 1.0,
"vendor": "smc",
"version": "*"
},
{
"model": null,
"scope": null,
"trust": 0.8,
"vendor": "smc",
"version": null
},
{
"model": "smc8024l2",
"scope": null,
"trust": 0.8,
"vendor": "smc",
"version": null
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#377915"
},
{
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
},
{
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/h:smc_networks:smc8024l2",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Elio Torrisi",
"sources": [
{
"db": "BID",
"id": "54390"
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
}
],
"trust": 0.9
},
"cve": "CVE-2012-2974",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2012-2974",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"availabilityRequirement": "NOT DEFINED",
"baseScore": 10.0,
"collateralDamagePotential": "NOT DEFINED",
"confidentialityImpact": "COMPLETE",
"confidentialityRequirement": "NOT DEFINED",
"enviromentalScore": 8.1,
"exploitability": "PROOF-OF-CONCEPT",
"exploitabilityScore": 10.0,
"id": "CVE-2012-2974",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"integrityRequirement": "NOT DEFINED",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"remediationLevel": "UNAVAILABLE",
"reportConfidence": "UNCOFIRMED",
"severity": "HIGH",
"targetDistribution": "NOT DEFINED",
"trust": 0.8,
"userInteractionRequired": null,
"vector_string": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-56255",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2012-2974",
"trust": 1.6,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2012-2974",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201207-146",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-56255",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#377915"
},
{
"db": "VULHUB",
"id": "VHN-56255"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
},
{
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The web interface on the SMC SMC8024L2 switch allows remote attackers to bypass authentication and obtain administrative access via a direct request to a .html file under (1) status/, (2) system/, (3) ports/, (4) trunks/, (5) vlans/, (6) qos/, (7) rstp/, (8) dot1x/, (9) security/, (10) igmps/, or (11) snmp/. SMC8024L2 There is an authentication bypass vulnerability in the web management screen. SMC Networks Inc. Network switch provided by SMC8024L2 There is an authentication bypass vulnerability in the web management screen. In the web interface URL By directly entering, you can access without requiring authentication.A remote attacker may change the settings of the product. The SMC Networks SMC8024L2 Switch is a powerful switch. The WEB interface of the SMC Networks SMC8024L2 switch incorrectly restricts user access. The SMC8024L2 is a multifunctional 10/100/1000BASE-T independently managed switch",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-2974"
},
{
"db": "CERT/CC",
"id": "VU#377915"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"db": "BID",
"id": "54390"
},
{
"db": "VULHUB",
"id": "VHN-56255"
}
],
"trust": 3.24
},
"exploit_availability": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"reference": "https://www.kb.cert.org/vuls/id/377915",
"trust": 0.8,
"type": "poc"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#377915"
}
]
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#377915",
"trust": 3.9
},
{
"db": "NVD",
"id": "CVE-2012-2974",
"trust": 3.4
},
{
"db": "SECTRACK",
"id": "1027285",
"trust": 1.1
},
{
"db": "BID",
"id": "54390",
"trust": 1.0
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2012-3684",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "19986",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-56255",
"trust": 0.1
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#377915"
},
{
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"db": "VULHUB",
"id": "VHN-56255"
},
{
"db": "BID",
"id": "54390"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
},
{
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"id": "VAR-201207-0169",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"db": "VULHUB",
"id": "VHN-56255"
}
],
"trust": 1.3666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-3684"
}
]
},
"last_update_date": "2025-04-11T23:09:58.060000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SMC8024L2",
"trust": 0.8,
"url": "http://www.smc.com/index.cfm?event=viewProduct\u0026cid=8\u0026scid=44\u0026localeCode=EN_USA\u0026pid=1542"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-56255"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "http://www.kb.cert.org/vuls/id/377915"
},
{
"trust": 1.1,
"url": "http://www.securitytracker.com/id?1027285"
},
{
"trust": 0.8,
"url": "about vulnerability notes"
},
{
"trust": 0.8,
"url": "contact us about this vulnerability"
},
{
"trust": 0.8,
"url": "provide a vendor statement"
},
{
"trust": 0.8,
"url": "http://www.smc.com/index.cfm?event=viewproduct\u0026cid=8\u0026scid=44\u0026localecode=en_usa\u0026pid=1542"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-2974"
},
{
"trust": 0.8,
"url": "http://jvn.jp/cert/jvnvu377915/index.html"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-2974"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/54390"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/19986"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#377915"
},
{
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"db": "VULHUB",
"id": "VHN-56255"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
},
{
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#377915"
},
{
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"db": "VULHUB",
"id": "VHN-56255"
},
{
"db": "BID",
"id": "54390"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
},
{
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-07-11T00:00:00",
"db": "CERT/CC",
"id": "VU#377915"
},
{
"date": "2012-07-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"date": "2012-07-19T00:00:00",
"db": "VULHUB",
"id": "VHN-56255"
},
{
"date": "2012-07-11T00:00:00",
"db": "BID",
"id": "54390"
},
{
"date": "2012-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"date": "2012-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201207-146"
},
{
"date": "2012-07-19T15:55:02.783000",
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-07-11T00:00:00",
"db": "CERT/CC",
"id": "VU#377915"
},
{
"date": "2012-07-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-3684"
},
{
"date": "2017-12-22T00:00:00",
"db": "VULHUB",
"id": "VHN-56255"
},
{
"date": "2012-07-11T00:00:00",
"db": "BID",
"id": "54390"
},
{
"date": "2012-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-003056"
},
{
"date": "2012-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201207-146"
},
{
"date": "2025-04-11T00:51:21.963000",
"db": "NVD",
"id": "CVE-2012-2974"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SMC Networks SMC8024L2 Switch Web Interface Authentication Bypass Vulnerability",
"sources": [
{
"db": "BID",
"id": "54390"
},
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
}
],
"trust": 0.9
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201207-146"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.