The Dell KACE K2000 Systems Deployment Appliance 3.3.36822 and earlier contains a peinst CIFS share, which allows remote attackers to obtain sensitive information by reading the (1) unattend.xml or (2) sysprep.inf file, as demonstrated by reading a password. Dell Kace K2000 Systems Deployment Appliance Contains a vulnerability. Dell Kace K2000 Systems Deployment Appliance Is Windows You are using a file share for installation. This file share has a hidden attribute, Windows Contains files used at startup. Access to this file share is not restricted and may be accessed without authentication. In addition, Dell The following vulnerability information has been released. This hidden, read-only fileshare is populated with pre- and post-installation tasks as well as deployment bootfiles and media used for Windows network operating system installs (called "Scripted Installs") and imaging (called "K-images"). This fileshare is hidden. Dell Kace K2000 is prone to a remote information-disclosure vulnerability. Attackers can exploit this issue to obtain potentially sensitive information that may lead to further attacks

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201104-0209",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "kace k2000 systems deployment appliance",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "dell",
        "version": "3.3.36822"
      },
      {
        "model": null,
        "scope": null,
        "trust": 0.8,
        "vendor": "dell computer",
        "version": null
      },
      {
        "model": "kace k2000 systems deployment appliance",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "dell",
        "version": "version 3.3.36822"
      },
      {
        "model": "kace k2000 systems deployment appliance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "dell",
        "version": "3.3.36822"
      },
      {
        "model": "kace k2000",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "dell",
        "version": "0"
      }
    ],
    "sources": [
      {
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "db": "BID",
        "id": "47172"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/h:dell:kace_k2000_systems_deployment_appliance",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Cody Green",
    "sources": [
      {
        "db": "BID",
        "id": "47172"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2011-1672",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-1672",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-49617",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-1672",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CARNEGIE MELLON",
            "id": "VU#598700",
            "trust": 0.8,
            "value": "10.80"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-1672",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201104-071",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-49617",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49617"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The Dell KACE K2000 Systems Deployment Appliance 3.3.36822 and earlier contains a peinst CIFS share, which allows remote attackers to obtain sensitive information by reading the (1) unattend.xml or (2) sysprep.inf file, as demonstrated by reading a password. Dell Kace K2000 Systems Deployment Appliance Contains a vulnerability. Dell Kace K2000 Systems Deployment Appliance Is Windows You are using a file share for installation. This file share has a hidden attribute, Windows Contains files used at startup. Access to this file share is not restricted and may be accessed without authentication. In addition, Dell The following vulnerability information has been released. This hidden, read-only fileshare is populated with pre- and post-installation tasks as well as deployment bootfiles and media used for Windows network operating system installs (called \"Scripted Installs\") and imaging (called \"K-images\"). This fileshare is hidden. Dell Kace K2000 is prone to a remote information-disclosure vulnerability. \nAttackers can exploit this issue to obtain potentially sensitive information that may lead to further attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-1672"
      },
      {
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      },
      {
        "db": "BID",
        "id": "47172"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49617"
      }
    ],
    "trust": 3.42
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "CERT/CC",
        "id": "VU#598700",
        "trust": 4.1
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1672",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "47172",
        "trust": 1.4
      },
      {
        "db": "VUPEN",
        "id": "ADV-2011-0883",
        "trust": 1.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-001454",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-49617",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49617"
      },
      {
        "db": "BID",
        "id": "47172"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "id": "VAR-201104-0209",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-49617"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2025-04-11T22:59:32.049000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "KACE",
        "trust": 0.8,
        "url": "http://www.kace.com/"
      },
      {
        "title": "K2000 peinst file share information",
        "trust": 0.8,
        "url": "http://www.kace.com/support/kb/index.php?action=artikel\u0026cat=1\u0026id=1104"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-200",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-49617"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.3,
        "url": "http://www.kb.cert.org/vuls/id/598700"
      },
      {
        "trust": 2.7,
        "url": "http://www.kace.com/support/kb/index.php?action=artikel\u0026cat=1\u0026id=1104"
      },
      {
        "trust": 1.1,
        "url": "http://www.securityfocus.com/bid/47172"
      },
      {
        "trust": 1.1,
        "url": "http://www.vupen.com/english/advisories/2011/0883"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/66630"
      },
      {
        "trust": 0.8,
        "url": "about vulnerability notes"
      },
      {
        "trust": 0.8,
        "url": "contact us about this vulnerability"
      },
      {
        "trust": 0.8,
        "url": "provide a vendor statement"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-1672"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-1672"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/cert/jvnvu598700"
      },
      {
        "trust": 0.3,
        "url": "http://dell.com"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/"
      },
      {
        "trust": 0.1,
        "url": "http://www.kace.com/support/kb/index.php?action=artikel\u0026amp;cat=1\u0026amp;id=1104"
      }
    ],
    "sources": [
      {
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49617"
      },
      {
        "db": "BID",
        "id": "47172"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49617"
      },
      {
        "db": "BID",
        "id": "47172"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-04-05T00:00:00",
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "date": "2011-04-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-49617"
      },
      {
        "date": "2011-04-05T00:00:00",
        "db": "BID",
        "id": "47172"
      },
      {
        "date": "2012-03-27T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "date": "2011-04-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      },
      {
        "date": "2011-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      },
      {
        "date": "2011-04-10T02:55:01.680000",
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-04-05T00:00:00",
        "db": "CERT/CC",
        "id": "VU#598700"
      },
      {
        "date": "2017-08-17T00:00:00",
        "db": "VULHUB",
        "id": "VHN-49617"
      },
      {
        "date": "2015-04-13T21:01:00",
        "db": "BID",
        "id": "47172"
      },
      {
        "date": "2012-03-27T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-004478"
      },
      {
        "date": "2011-04-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-001454"
      },
      {
        "date": "2011-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-1672"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Dell Kace K2000 Appliance unauthenticated access and information disclosure vulnerability",
    "sources": [
      {
        "db": "CERT/CC",
        "id": "VU#598700"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "information disclosure",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201104-071"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.