VAR-200603-0106

Vulnerability from variot - Updated: 2025-04-03 22:16

Unspecified vulnerability in the ESS/ Network Controller in Xerox CopyCentre and Xerox WorkCentre Pro, running software 1.001.02.073 or earlier, or 1.001.02.074 before 1.001.02.715, causes the Immediate Image Overwrite feature to fail after a power loss, which could leave data exposed to attack. CopyCentre C75 is prone to a remote security vulnerability.

TITLE: Xerox CopyCentre / WorkCentre Pro Multiple Denial of Service Vulnerabilities

SECUNIA ADVISORY ID: SA19146

VERIFY ADVISORY: http://secunia.com/advisories/19146/

CRITICAL: Moderately critical

IMPACT: Unknown, DoS

WHERE:

From remote

OPERATING SYSTEM: Xerox CopyCentre http://secunia.com/product/8595/ Xerox WorkCentre Pro http://secunia.com/product/4553/

DESCRIPTION: Some vulnerabilities have been reported in Xerox CopyCentre and Xerox WorkCentre Pro, where one has an unknown impact, and others can be exploited by malicious people to cause a DoS (Denial of Service).

1) An unspecified boundary error in the PostScript file interpreter can be exploited to cause a buffer overflow.

Successful exploitation causes a denial of service on a vulnerable device.

2) Two unspecified errors in the handling of PostScript files can be exploited to cause a denial of service on a vulnerable device via a specially crafted PostScript file.

3) An unspecified error in the built-in web server can be exploited to cause a memory corruption.

Successful exploitation causes a denial of service on a vulnerable device.

The vulnerabilities affect the following products: * Xerox CopyCentre C65, C75, and C90. * Xerox WorkCentre Pro 65, 75, and 90.

SOLUTION: Install System Software Version 1.001.02.074 or 1.001.02.716 (the software versions can be obtained by contacting Xerox customer support).

PROVIDED AND/OR DISCOVERED BY: Reported by the vendor.

ORIGINAL ADVISORY: http://www.xerox.com/downloads/usa/en/c/cert_XRX06_002.pdf


About: This Advisory was delivered by Secunia as a free service to help everybody keeping their systems up to date against the latest vulnerabilities.

Subscribe: http://secunia.com/secunia_security_advisories/

Definitions: (Criticality, Where etc.) http://secunia.com/about_secunia_advisories/

Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.


Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org


Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-200603-0106",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "copycentre c65",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.074"
      },
      {
        "model": "workcentre pro 65",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre pro 75",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.715"
      },
      {
        "model": "workcentre pro 90",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.715"
      },
      {
        "model": "workcentre pro 65",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.074"
      },
      {
        "model": "copycentre c90",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre pro 90",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre pro 65",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.715"
      },
      {
        "model": "copycentre c75",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.715"
      },
      {
        "model": "copycentre c90",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.074"
      },
      {
        "model": "copycentre c75",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre pro 75",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "copycentre c65",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.715"
      },
      {
        "model": "copycentre c90",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.715"
      },
      {
        "model": "copycentre c65",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre pro 90",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.074"
      },
      {
        "model": "copycentre c75",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.074"
      },
      {
        "model": "workcentre pro 75",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "xerox",
        "version": "1.001.02.074"
      },
      {
        "model": "copycentre c75",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.0715"
      },
      {
        "model": "workcentre 75",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.0715"
      },
      {
        "model": "workcentre 90",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre 65",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.0715"
      },
      {
        "model": "copycentre c90",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.0715"
      },
      {
        "model": "workcentre 90",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.0715"
      },
      {
        "model": "copycentre c75",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre 75",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre 65",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "copycentre c90",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "xerox",
        "version": "1.001.02.073"
      },
      {
        "model": "workcentre pro",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "xerox",
        "version": "901.001.02.073"
      },
      {
        "model": "workcentre pro",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "xerox",
        "version": "901.001.02.0715"
      },
      {
        "model": "workcentre pro",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "xerox",
        "version": "751.001.02.073"
      },
      {
        "model": "workcentre pro",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "xerox",
        "version": "751.001.02.0715"
      },
      {
        "model": "workcentre pro",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "xerox",
        "version": "651.001.02.073"
      },
      {
        "model": "workcentre pro",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "xerox",
        "version": "651.001.02.0715"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "88044"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      },
      {
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unknown",
    "sources": [
      {
        "db": "BID",
        "id": "88044"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2006-1139",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2006-1139",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-17247",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2006-1139",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-200603-160",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-17247",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-17247"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      },
      {
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unspecified vulnerability in the ESS/ Network Controller in Xerox CopyCentre and Xerox WorkCentre Pro, running software 1.001.02.073 or earlier, or 1.001.02.074 before 1.001.02.715, causes the Immediate Image Overwrite feature to fail after a power loss, which could leave data exposed to attack. CopyCentre C75 is prone to a remote security vulnerability. \n\nTITLE:\nXerox CopyCentre / WorkCentre Pro Multiple Denial of Service\nVulnerabilities\n\nSECUNIA ADVISORY ID:\nSA19146\n\nVERIFY ADVISORY:\nhttp://secunia.com/advisories/19146/\n\nCRITICAL:\nModerately critical\n\nIMPACT:\nUnknown, DoS\n\nWHERE:\n\u003eFrom remote\n\nOPERATING SYSTEM:\nXerox CopyCentre\nhttp://secunia.com/product/8595/\nXerox WorkCentre Pro\nhttp://secunia.com/product/4553/\n\nDESCRIPTION:\nSome vulnerabilities have been reported in Xerox CopyCentre and Xerox\nWorkCentre Pro, where one has an unknown impact, and others can be\nexploited by malicious people to cause a DoS (Denial of Service). \n\n1) An unspecified boundary error in the PostScript file interpreter\ncan be exploited to cause a buffer overflow. \n\nSuccessful exploitation causes a denial of service on a vulnerable\ndevice. \n\n2) Two unspecified errors in the handling of PostScript files can be\nexploited to cause a denial of service on a vulnerable device via a\nspecially crafted PostScript file. \n\n3) An unspecified error in the built-in web server can be exploited\nto cause a memory corruption. \n\nSuccessful exploitation causes a denial of service on a vulnerable\ndevice. \n\nThe vulnerabilities affect the following products:\n* Xerox CopyCentre C65, C75, and C90. \n* Xerox WorkCentre Pro 65, 75, and 90. \n\nSOLUTION:\nInstall System Software Version 1.001.02.074 or 1.001.02.716 (the\nsoftware versions can be obtained by contacting Xerox customer\nsupport). \n\nPROVIDED AND/OR DISCOVERED BY:\nReported by the vendor. \n\nORIGINAL ADVISORY:\nhttp://www.xerox.com/downloads/usa/en/c/cert_XRX06_002.pdf\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\neverybody keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2006-1139"
      },
      {
        "db": "BID",
        "id": "88044"
      },
      {
        "db": "VULHUB",
        "id": "VHN-17247"
      },
      {
        "db": "PACKETSTORM",
        "id": "44411"
      }
    ],
    "trust": 1.35
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "SECTRACK",
        "id": "1015738",
        "trust": 2.0
      },
      {
        "db": "NVD",
        "id": "CVE-2006-1139",
        "trust": 2.0
      },
      {
        "db": "SECUNIA",
        "id": "19146",
        "trust": 1.8
      },
      {
        "db": "OSVDB",
        "id": "23728",
        "trust": 1.7
      },
      {
        "db": "VUPEN",
        "id": "ADV-2006-0857",
        "trust": 1.7
      },
      {
        "db": "XF",
        "id": "25176",
        "trust": 0.9
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160",
        "trust": 0.7
      },
      {
        "db": "BID",
        "id": "88044",
        "trust": 0.3
      },
      {
        "db": "VULHUB",
        "id": "VHN-17247",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "44411",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-17247"
      },
      {
        "db": "BID",
        "id": "88044"
      },
      {
        "db": "PACKETSTORM",
        "id": "44411"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      },
      {
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "id": "VAR-200603-0106",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-17247"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2025-04-03T22:16:23.752000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.1,
        "url": "http://www.xerox.com/downloads/usa/en/c/cert_xrx06_002.pdf"
      },
      {
        "trust": 2.0,
        "url": "http://securitytracker.com/id?1015738"
      },
      {
        "trust": 1.7,
        "url": "http://www.osvdb.org/23728"
      },
      {
        "trust": 1.7,
        "url": "http://secunia.com/advisories/19146"
      },
      {
        "trust": 1.1,
        "url": "http://www.vupen.com/english/advisories/2006/0857"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/25176"
      },
      {
        "trust": 0.9,
        "url": "http://xforce.iss.net/xforce/xfdb/25176"
      },
      {
        "trust": 0.6,
        "url": "http://www.frsirt.com/english/advisories/2006/0857"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/secunia_security_advisories/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/product/8595/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/product/4553/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/19146/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/about_secunia_advisories/"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-17247"
      },
      {
        "db": "BID",
        "id": "88044"
      },
      {
        "db": "PACKETSTORM",
        "id": "44411"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      },
      {
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-17247"
      },
      {
        "db": "BID",
        "id": "88044"
      },
      {
        "db": "PACKETSTORM",
        "id": "44411"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      },
      {
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2006-03-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-17247"
      },
      {
        "date": "2006-03-09T00:00:00",
        "db": "BID",
        "id": "88044"
      },
      {
        "date": "2006-03-08T04:17:23",
        "db": "PACKETSTORM",
        "id": "44411"
      },
      {
        "date": "2006-03-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      },
      {
        "date": "2006-03-10T02:02:00",
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-04T00:00:00",
        "db": "VULHUB",
        "id": "VHN-17247"
      },
      {
        "date": "2006-03-09T00:00:00",
        "db": "BID",
        "id": "88044"
      },
      {
        "date": "2006-03-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      },
      {
        "date": "2025-04-03T01:03:51.193000",
        "db": "NVD",
        "id": "CVE-2006-1139"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Xerox CopyCentre and Xerox WorkCentre Pro ESS/ Network Controller Unknown vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "unknown",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200603-160"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.