VAR-200404-0064

Vulnerability from variot - Updated: 2025-04-03 22:38

Samsung SmartEther SS6215S switch, and possibly other Samsung switches, allows remote attackers and local users to gain administrative access by providing the admin username followed by a password that is the maximum allowed length, then pressing the enter key after the resulting error message. When accessing a Samsung SmartEther switch, via the telnet service or serial connection, authentication is required and the user is presented with a logon screen. It has been reported that it is possible to bypass this authentication procedure. An attacker may potentially exploit this condition to, for example, modify static MAC address mapping and perhaps enable man-in-the-middle style attacks. Other attacks are certainly possible. Samsung SmartEther SS6215S is a network switch. When connecting to a Samsung SmartEther switch, enter the user name \"admin\", enter the longest combination of characters in the password field (unable to enter) as the password data, and then press Enter, although it will prompt that the password does not match, but into the system

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-200404-0064",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "smartether ss6215s switch",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "securecomputing",
        "version": "*"
      },
      {
        "model": "smartether ss6215s switch",
        "scope": null,
        "trust": 0.6,
        "vendor": "securecomputing",
        "version": null
      },
      {
        "model": "smartether ss6215s switch",
        "scope": null,
        "trust": 0.3,
        "vendor": "samsung",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "10219"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Kyle Duren\u203b acidrain_ask@pixitha.com",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2004-1970",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2004-1970",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-10398",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2004-1970",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-200404-089",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-10398",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2004-1970",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10398"
      },
      {
        "db": "VULMON",
        "id": "CVE-2004-1970"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Samsung SmartEther SS6215S switch, and possibly other Samsung switches, allows remote attackers and local users to gain administrative access by providing the admin username followed by a password that is the maximum allowed length, then pressing the enter key after the resulting error message. When accessing a Samsung SmartEther switch, via the telnet service or serial connection, authentication is required and the user is presented with a logon screen. It has been reported that it is possible to bypass this authentication procedure. \nAn attacker may potentially exploit this condition to, for example, modify static MAC address mapping and perhaps enable man-in-the-middle style attacks. Other attacks are certainly possible. Samsung SmartEther SS6215S is a network switch. When connecting to a Samsung SmartEther switch, enter the user name \\\"admin\\\", enter the longest combination of characters in the password field (unable to enter) as the password data, and then press Enter, although it will prompt that the password does not match, but into the system",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2004-1970"
      },
      {
        "db": "BID",
        "id": "10219"
      },
      {
        "db": "VULHUB",
        "id": "VHN-10398"
      },
      {
        "db": "VULMON",
        "id": "CVE-2004-1970"
      }
    ],
    "trust": 1.35
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "10219",
        "trust": 2.1
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1970",
        "trust": 1.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089",
        "trust": 0.7
      },
      {
        "db": "XF",
        "id": "15973",
        "trust": 0.6
      },
      {
        "db": "BUGTRAQ",
        "id": "20040426 SAMSUNG SMARTETHER SS6215S SWITCH",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-10398",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2004-1970",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10398"
      },
      {
        "db": "VULMON",
        "id": "CVE-2004-1970"
      },
      {
        "db": "BID",
        "id": "10219"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "id": "VAR-200404-0064",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10398"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2025-04-03T22:38:20.126000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "http://www.securityfocus.com/bid/10219"
      },
      {
        "trust": 1.2,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/15973"
      },
      {
        "trust": 1.1,
        "url": "http://marc.info/?l=bugtraq\u0026m=108300407424571\u0026w=2"
      },
      {
        "trust": 0.6,
        "url": "http://xforce.iss.net/xforce/xfdb/15973"
      },
      {
        "trust": 0.6,
        "url": "http://marc.theaimsgroup.com/?l=bugtraq\u0026m=108300407424571\u0026w=2"
      },
      {
        "trust": 0.3,
        "url": "/archive/1/361448"
      },
      {
        "trust": 0.1,
        "url": "http://marc.info/?l=bugtraq\u0026amp;m=108300407424571\u0026amp;w=2"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-10398"
      },
      {
        "db": "VULMON",
        "id": "CVE-2004-1970"
      },
      {
        "db": "BID",
        "id": "10219"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-10398"
      },
      {
        "db": "VULMON",
        "id": "CVE-2004-1970"
      },
      {
        "db": "BID",
        "id": "10219"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2004-04-26T00:00:00",
        "db": "VULHUB",
        "id": "VHN-10398"
      },
      {
        "date": "2004-04-26T00:00:00",
        "db": "VULMON",
        "id": "CVE-2004-1970"
      },
      {
        "date": "2004-04-26T00:00:00",
        "db": "BID",
        "id": "10219"
      },
      {
        "date": "2004-04-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      },
      {
        "date": "2004-04-26T04:00:00",
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2017-07-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-10398"
      },
      {
        "date": "2017-07-11T00:00:00",
        "db": "VULMON",
        "id": "CVE-2004-1970"
      },
      {
        "date": "2004-04-26T00:00:00",
        "db": "BID",
        "id": "10219"
      },
      {
        "date": "2005-10-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      },
      {
        "date": "2025-04-03T01:03:51.193000",
        "db": "NVD",
        "id": "CVE-2004-1970"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Samsung SmartEther Switch Firmware verification bypasses the vulnerability",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-200404-089"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.