SSA-970803

Vulnerability from csaf_siemens - Published: 2026-11-10 00:00 - Updated: 2026-11-10 00:00
Summary
SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems
Notes
Summary: The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.

Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.

CWE-1390 - Weak Authentication
Affected products
Product Identifier Version Remediation
SIMATIC BATCH V9.1
Siemens / SIMATIC BATCH V9.1
vers:all/*
Mitigation
No Fix Planned
SIMATIC WinCC Runtime Professional V20
Siemens / SIMATIC WinCC Runtime Professional V20
vers:all/*
Mitigation
None Available
SIMATIC WinCC Runtime Professional V21
Siemens / SIMATIC WinCC Runtime Professional V21
vers:all/*
Mitigation
None Available
SIMATIC WinCC V7.5
Siemens / SIMATIC WinCC V7.5
vers:all/*
Mitigation
None Available
SIMATIC WinCC V8.0
Siemens / SIMATIC WinCC V8.0
vers:all/*
Mitigation
None Available
SIMATIC WinCC V8.1
Siemens / SIMATIC WinCC V8.1
vers:all/*
Mitigation
None Available
SIMATIC Information Server 2020
Siemens / SIMATIC Information Server 2020
vers:all/*
Mitigation
No Fix Planned
SIMATIC Information Server 2022
Siemens / SIMATIC Information Server 2022
vers:all/*
Mitigation
No Fix Planned
SIMATIC PCS 7 V9.1
Siemens / SIMATIC PCS 7 V9.1
vers:all/*
Mitigation
No Fix Planned
SIMATIC Process Historian 2020
Siemens / SIMATIC Process Historian 2020
vers:all/*
Mitigation
No Fix Planned
SIMATIC Process Historian 2022
Siemens / SIMATIC Process Historian 2022
vers:all/*
Mitigation
No Fix Planned
SIMATIC WinCC Runtime Professional V17
Siemens / SIMATIC WinCC Runtime Professional V17
vers:all/*
Mitigation
None Available
SIMATIC WinCC Runtime Professional V18
Siemens / SIMATIC WinCC Runtime Professional V18
vers:all/*
Mitigation
None Available
SIMATIC WinCC Runtime Professional V19
Siemens / SIMATIC WinCC Runtime Professional V19
vers:all/*
Mitigation
None Available

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user.\n\nSiemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-970803.html"
      },
      {
        "category": "self",
        "summary": "SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-970803.json"
      }
    ],
    "title": "SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems",
    "tracking": {
      "current_release_date": "2026-11-10T00:00:00.000Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-970803",
      "initial_release_date": "2026-11-10T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2026-11-10T00:00:00.000Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "interim",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC BATCH V9.1",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC BATCH V9.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Information Server 2020",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Information Server 2020"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Information Server 2022",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Information Server 2022"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC PCS 7 V9.1",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS 7 V9.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Process Historian 2020",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Process Historian 2020"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC Process Historian 2022",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC Process Historian 2022"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V17",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V17"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V18",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V18"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V19",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V19"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V20",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V20"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V21",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V21"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC V7.5",
                  "product_id": "12"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V7.5"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC V8.0",
                  "product_id": "13"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V8.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC V8.1",
                  "product_id": "14"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V8.1"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2026-58114",
      "cwe": {
        "id": "CWE-1390",
        "name": "Weak Authentication"
      },
      "notes": [
        {
          "category": "description",
          "text": "Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "10",
          "11",
          "12",
          "13",
          "14",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635\u0026lc=en-ID",
          "product_ids": [
            "1",
            "10",
            "11",
            "12",
            "13",
            "14",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9"
          ]
        },
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "10",
            "11",
            "12",
            "13",
            "14",
            "7",
            "8",
            "9"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1",
            "10",
            "11",
            "12",
            "13",
            "14",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9"
          ]
        }
      ],
      "title": "CVE-2026-58114"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.